Home > NEC > Communications System > NEC Ds2000 Software Instructions Manual

NEC Ds2000 Software Instructions Manual

Here you can view all the pages of manual NEC Ds2000 Software Instructions Manual. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 541

1800 - Extension Options
1801 - Extension Port Description
DS1000/2000 Software Manual Chapter 2: Programming533
DSS TypeUse this option to specify the type of DSS 
Console plugged into the telephone (1 = 24-
button, 2 = 110-button, 0 = unassigned). You 
cannot install more than 4 DSS Consoles.
• See Direct Station Selection (DSS) Con-
sole on page 128 for more.DSS TYP?0 = Uninstalled
1 = 24-Button
2 = 110 Button300 = 1
301-331 = 0
DSS Block NumberUse this option to assign a DSS block to the 
console.
•...

Page 542

1800 - Extension Options
1801 - Extension Port Description
534Chapter 2: ProgrammingDS1000/2000 Software Manual
Extension Toll  Level 
NightUse this option to assign an extension’s Toll 
Level during the night mode.
• See Toll Restriction on page 385 for 
more.STA TOLL LVL NITE?1-7, 0 = No restriction00
DCI Class of Service 
Assignment• This option is currently not used. DCI COS?1=151
DCI Toll Level Day• This option is currently not used. DCI TOLL LVL DAY?1-7, 0 = No restriction1
DCI Toll Level Night•...

Page 543

1800 - Extension Options
1801 - Extension Port Description
DS1000/2000 Software Manual Chapter 2: Programming535
Telephone Programming Instructions
1. Enter the programming mode.
2. 1801 + 
HOLD
3. Enter the number of the extension you want to program (300-395) + HOLD
OR
Press 
HOLD to select extension 300.
 The previously programmed value displays. See the chart above for valid circuit types.
4. Enter the new station circuit type + 
VO L 
OR
Press 
VO L  to leave the current circuit type unchanged....

Page 544

1800 - Extension Options
1801 - Extension Port Description
536Chapter 2: ProgrammingDS1000/2000 Software Manual
If you already have 4 DSS Consoles installed, and you try to install a 5th, you see the 
message: TABLE FULL. You cannot install more than 4 DSS Consoles.
9. If installed, enter the DSS Console type (00-02) + 
VO L 
OR
Press 
VO L  to leave the current entry unchanged
10. If installed, enter the DSS Console block number (if installed) + 
VO L 
OR
Press 
VO L  to leave the current entry...

Page 545

1800 - Extension Options
1801 - Extension Port Description
DS1000/2000 Software Manual Chapter 2: Programming537
The previously programmed value displays.
17. For 3DCI Modules, enter the module’s night mode Toll Level (1-7, 0 = No restriction) + 
VO L 

OR
Press 
VO L  to leave the current entry unchanged
The previously programmed value displays.
18. Enter the extension’s Access Level (0-5) + 
VO L 
OR
Press 
VO L  to leave the current entry unchanged
The previously programmed value displays.
19....

Page 546

1800 - Extension Options
1801 - Extension Port Description
538Chapter 2: ProgrammingDS1000/2000 Software Manual
The previously programmed value displays.
24. Press 
CONF to select another station port to program.
OR
Press 
CONF twice to exit this program. 

Page 547

1800 - Extension Options
1802 - Extension Options (Part 1)
DS1000/2000 Software Manual Chapter 2: Programming539
1802 - Extension Options (Part 1)
Description
Use Program 1802 - Extension Options (Part 1) to set up additional options for extensions. Also 
see Program 1801 - Extension Port Description on page 532 and Program 1807 - Extension 
Options (Part 2) on page 553.
Note: If you are doing extensive programming, you may find Program 9801 - Copy Command 
(page 557) saves you time when customizing this...

Page 548

1800 - Extension Options
1802 - Extension Options (Part 1)
540Chapter 2: ProgrammingDS1000/2000 Software Manual
Off-Hook Signaling for 
CO CallsUse this option to assign an extension’s Off-
Hook Signaling options for trunk calls.
• See Attendant Position on page 46 for 
more.
• See Central Office Calls, Answering on 
page 87 for more.
• See Off-Hook Signaling on page 270 for 
more.OHS CO?0 = No Off-Hook
Signaling
1 = Camp On tone
2 = Off hook ringing1
Handsfree Reply on 
Intercom CallsUse this option to...

Page 549

1800 - Extension Options
1802 - Extension Options (Part 1)
DS1000/2000 Software Manual Chapter 2: Programming541
Telephone Programming Instructions
1. Enter the programming mode.
Key Access to Outbound 
LinesUse this option to enable or disable the 
extension user’s ability to press a Program-
mable Function Key to access and outside 
line.
• See Central Office Calls, Placing on 
page 93 for more.
• See Line Keys on page 238 for more.
• See Programmable Function Keys on 
page 304 for more.KEY ACESS TO...

Page 550

1800 - Extension Options
1802 - Extension Options (Part 1)
542Chapter 2: ProgrammingDS1000/2000 Software Manual
2. 1802 + HOLD
3. Enter the extension number (300-395 in DS2000 or 300-325 in DS1000) you want to program 
+ 
HOLD
OR
Press 
HOLD to select extension 300.
 The previously programmed value displays.
4. Enter the Y to enable or N to disable Do Not Disturb + 
VO L 
OR
Press 
VO L  to leave the current assignment unchanged
 The previously programmed value displays.
5. Enter the extension’s Ring...
Start reading NEC Ds2000 Software Instructions Manual

Related Manuals for NEC Ds2000 Software Instructions Manual

All NEC manuals