Page 541
1800 - Extension Options 1801 - Extension Port Description DS1000/2000 Software Manual Chapter 2: Programming533 DSS TypeUse this option to specify the type of DSS Console plugged into the telephone (1 = 24- button, 2 = 110-button, 0 = unassigned). You cannot install more than 4 DSS Consoles. • See Direct Station Selection (DSS) Con- sole on page 128 for more.DSS TYP?0 = Uninstalled 1 = 24-Button 2 = 110 Button300 = 1 301-331 = 0 DSS Block NumberUse this option to assign a DSS block to the console. •...
Page 542
1800 - Extension Options 1801 - Extension Port Description 534Chapter 2: ProgrammingDS1000/2000 Software Manual Extension Toll Level NightUse this option to assign an extension’s Toll Level during the night mode. • See Toll Restriction on page 385 for more.STA TOLL LVL NITE?1-7, 0 = No restriction00 DCI Class of Service Assignment• This option is currently not used. DCI COS?1=151 DCI Toll Level Day• This option is currently not used. DCI TOLL LVL DAY?1-7, 0 = No restriction1 DCI Toll Level Night•...
Page 543
1800 - Extension Options 1801 - Extension Port Description DS1000/2000 Software Manual Chapter 2: Programming535 Telephone Programming Instructions 1. Enter the programming mode. 2. 1801 + HOLD 3. Enter the number of the extension you want to program (300-395) + HOLD OR Press HOLD to select extension 300. The previously programmed value displays. See the chart above for valid circuit types. 4. Enter the new station circuit type + VO L OR Press VO L to leave the current circuit type unchanged....
Page 544
1800 - Extension Options 1801 - Extension Port Description 536Chapter 2: ProgrammingDS1000/2000 Software Manual If you already have 4 DSS Consoles installed, and you try to install a 5th, you see the message: TABLE FULL. You cannot install more than 4 DSS Consoles. 9. If installed, enter the DSS Console type (00-02) + VO L OR Press VO L to leave the current entry unchanged 10. If installed, enter the DSS Console block number (if installed) + VO L OR Press VO L to leave the current entry...
Page 545
1800 - Extension Options 1801 - Extension Port Description DS1000/2000 Software Manual Chapter 2: Programming537 The previously programmed value displays. 17. For 3DCI Modules, enter the module’s night mode Toll Level (1-7, 0 = No restriction) + VO L OR Press VO L to leave the current entry unchanged The previously programmed value displays. 18. Enter the extension’s Access Level (0-5) + VO L OR Press VO L to leave the current entry unchanged The previously programmed value displays. 19....
Page 546
1800 - Extension Options 1801 - Extension Port Description 538Chapter 2: ProgrammingDS1000/2000 Software Manual The previously programmed value displays. 24. Press CONF to select another station port to program. OR Press CONF twice to exit this program.
Page 547
1800 - Extension Options 1802 - Extension Options (Part 1) DS1000/2000 Software Manual Chapter 2: Programming539 1802 - Extension Options (Part 1) Description Use Program 1802 - Extension Options (Part 1) to set up additional options for extensions. Also see Program 1801 - Extension Port Description on page 532 and Program 1807 - Extension Options (Part 2) on page 553. Note: If you are doing extensive programming, you may find Program 9801 - Copy Command (page 557) saves you time when customizing this...
Page 548
1800 - Extension Options 1802 - Extension Options (Part 1) 540Chapter 2: ProgrammingDS1000/2000 Software Manual Off-Hook Signaling for CO CallsUse this option to assign an extension’s Off- Hook Signaling options for trunk calls. • See Attendant Position on page 46 for more. • See Central Office Calls, Answering on page 87 for more. • See Off-Hook Signaling on page 270 for more.OHS CO?0 = No Off-Hook Signaling 1 = Camp On tone 2 = Off hook ringing1 Handsfree Reply on Intercom CallsUse this option to...
Page 549
1800 - Extension Options 1802 - Extension Options (Part 1) DS1000/2000 Software Manual Chapter 2: Programming541 Telephone Programming Instructions 1. Enter the programming mode. Key Access to Outbound LinesUse this option to enable or disable the extension user’s ability to press a Program- mable Function Key to access and outside line. • See Central Office Calls, Placing on page 93 for more. • See Line Keys on page 238 for more. • See Programmable Function Keys on page 304 for more.KEY ACESS TO...
Page 550
1800 - Extension Options 1802 - Extension Options (Part 1) 542Chapter 2: ProgrammingDS1000/2000 Software Manual 2. 1802 + HOLD 3. Enter the extension number (300-395 in DS2000 or 300-325 in DS1000) you want to program + HOLD OR Press HOLD to select extension 300. The previously programmed value displays. 4. Enter the Y to enable or N to disable Do Not Disturb + VO L OR Press VO L to leave the current assignment unchanged The previously programmed value displays. 5. Enter the extension’s Ring...