System Programming Password Protection DS1000/2000 Software ManualChapter 1: Features363 Other Related Features System Programming Backup and Restore (page 357) Backup your system programming to a PC card provides for a permanent, non-volatile backup of all the site’s programming. System Programming List (page 360) Review the complete list of programmable options. Feature Operation None
Page 372
System Timers 364Chapter 1: FeaturesDS1000/2000 Software Manual System Timers Description The system-wide timers allow the adminstrator system performance to meet the specific application requirements. Review the table below for a description of each timer. Following is a summary of the Program 0401 - System Timers (page 455) options. DS2000 Fixed Slot Available. DS2000 U Slot DS1000 Use the system-side timers to tailor the system to the site’s requirements. Table 12: Program 0401 - System Timers (Page...
Page 373
System Timers DS1000/2000 Software ManualChapter 1: Features365 Conditions None Default Setting See the table above. DIL No AnswerThis timer sets how long a DIL to an extension rings before Key Ring or overflow occurs. Key Ring rings all extensions programmed to ring for that line.15 sec. Trunk RevertThis timer sets how long Hold Recall rings the exten- sion that placed the call on hold before Key Ring occurs. Key Ring rings all extensions programmed to ring for that line. This timer also sets how...
Page 374
System Timers 366Chapter 1: FeaturesDS1000/2000 Software Manual Programming List Program 0401 - System Timers (page 455) The system-wide timers allow the adminstrator system performance to meet the specific appli- cation requirements. Other Related Features Refer to the following for related feature information: Program 0401 - System Timers (page 455) Feature Operation None
Page 375
System Timers, Stations DS1000/2000 Software ManualChapter 1: Features367 System Timers, Stations Description The system provides many station timers that the administrator can customize. Review the tables below for a description of each station timer. Following is a summary of the Program 0403 - Station Timers (page 466). DS2000 Fixed Slot Available. DS2000 U Slot DS1000 Adjustable station timers allow the system to more precisely meet the site requirements. Table 13: Program 0403 - Station Timers...
Page 376
System Timers, Stations 368Chapter 1: FeaturesDS1000/2000 Software Manual Number of Extended RingsIf an extension’s Class of Service enables Extended Ringing, use the timer to set the duration of the Extended Ringing.20 sec. Drop Pulse SendUse this timer to set the duration of the ASTU PCB drop pulse. This pulse is sent from the ASTU PCB to the connected analog device to initiate a disconnect.300 mS DTMF DetectUse this timer to set the DTMF detection threshold for single line (analog device)...
Page 377
System Timers, Stations DS1000/2000 Software ManualChapter 1: Features369 Following is a summary of the Program 0404 - Analog Station Timers (page 469). Table 14: Program 0404 - Analog Station Timers (Page 1 of 2) OptionDescriptionDefault Country Data Use this option to define the country of use and the codec digitizing method for ASTU PCBs. This timer consists of two bits (xy), with bit x defining the coun- try and bit y defining the digitization method. For example, the default entry 00 is for North...
Page 378
System Timers, Stations 370Chapter 1: FeaturesDS1000/2000 Software Manual Conditions None Default Setting Refer to the charts above. Minimum Hookflash TimeFor ASTU PCBs, this timer defines the minimum amount of time the loop must be opened before the system starts to detect a transfer or hang up sequence. Open loop intervals shorter than the setting are ignored by the ASTU PCB.21 (105 MS) Maximum Hookflash TimeFor ASTU PCBs, this timer defines the maximum amount of time the loop can be opened in order...
Page 379
System Timers, Stations DS1000/2000 Software ManualChapter 1: Features371 Programming List Program 0403 - Station Timers (page 466) Customize general station timers. Program 0404 - Analog Station Timers (page 469) Customize analog station timers. Other Related Features Refer to the following for related feature information: Program 0403 - Station Timers (page 466) Program 0404 - Analog Station Timers (page 469) Feature Operation None
Page 380
System Timers, Trunks 372Chapter 1: FeaturesDS1000/2000 Software Manual System Timers, Trunks Description The system provides many trunk timers that the administrator can customize. Review the table below for a description of each trunk timer. Following is a summary of the Program 0402 - Trunk Timers (page 459). Refer also to: Rules for Detecting Normal CO (Single) Ring on page 376. Rules for Detecting Special (Double) Ring on page 376. Rules for Detecting Loop Current on page 377. DS2000 Fixed...