Page 191

MultiVOIP User Guide Technical Configuration (Analog)
191
FXS Loop Start Interface: Parameter Definitions
Field Name Values Description
Message
Waiting LightY/N Applicable only when
MultiVOIP is used with Avaya
Magix PBX units equipped with
Merlin Messaging Centralized
mail.  When enabled, the
Message Waiting Light feature
allows  the PBX to send mode-
codes and message-waiting
indications to another Avaya
Magix PBX, which in turn will
turn on the message waiting
light on a phone station. It also
allows...

Page 192

MultiVOIP User Guide Technical Configuration (Analog)
192
FXS Ground Start Parameters (not supported).  The parameters
applicable to FXS Ground Start are shown in the figure below and
described in the table that follows.
FXS Ground Start Interface: Parameter Definitions
Field Name Values Description
FXS Ground
StartY/N Enables FXS Loop Start
interface type.
Inter Digit
Timerinteger values
in secondsThis is the length of time that
the MultiVOIP will wait
between digits.  When the time
expires, the...

Page 193

MultiVOIP User Guide Technical Configuration (Analog)
193
allows Direct Inward Dialing,
such that no additional dial
tone is needed on voip call.
Ring Count,
FXSinteger valuesMaximum number of rings that
the MultiVOIP will issue before
giving up the attempted call.
FXS Options,
Current LossY/NWhen enabled, the MultiVOIP
will interrupt loop current in
the FXS circuit to initiate a
disconnection.  This tells the
device connected to the FXS
port to hang up.  The Multi-
VOIP cannot drop the call; the
FXS...

Page 194

MultiVOIP User Guide Technical Configuration (Analog)
194
FXO Parameters.  The parameters applicable to the FXO telephony
interface type are shown in the figure below and described in the table
that follows. 

Page 195

MultiVOIP User Guide Technical Configuration (Analog)
195
FXO Interface: Parameter Definitions
Field Name Values Description
Interface, FXO Y/N Enables FXO functionality
Dialing Options
Regeneration Pulse, DTMF Determines whether digits
generated and sent out will be
pulse tones or DTMF.
Inter Digit
Timerinteger values,
in secondsThis is the length of time that
the MultiVOIP will wait
between digits.  When the time
expires, the MultiVOIP will
look in the phonebook for the
number entered.
Default = 2....

Page 196

MultiVOIP User Guide Technical Configuration (Analog)
196
FXO Interface: Parameter Definitions (cont’d)
Field Name Values Description
Dialing Options (cont’d)
Inter Digit
Regeneration
Timemilliseconds The length of time between the
outputting of DTMF digits.
Default = 100 ms.
FXO Disconnect OnThere are three possible criteria
for disconnection under FXO:
current loss, tone detection, and
silence detection.
Disconnection can be triggered
by more than one of the three
criteria.
Current Loss Y/N...

Page 197

MultiVOIP User Guide Technical Configuration (Analog)
197
FXO Interface: Parameter Definitions (cont’d)
Field Name Values Description
FXO Disconnect On (cont’d)
Disconnect
Tone Sequence1st tone pair
+
2
nd tone pairThese are DTMF tone pairs.
Values for first tone pair are:
*, #, 0, 1-9, and A-D.
Values for second tone 
pair are:
none, 0, 1-9, A-D, *, and #.
The tone pairs 1-9, 0, *, and #
are the standard DTMF pairs
found on phone sets.  The tone
pairs A-D are “extended
DTMF” tones, which are used
for...

Page 198

MultiVOIP User Guide Technical Configuration (Analog)
198
E&M Parameters.  The parameters applicable to the E&M telephony
interface type are shown in the figure below and described in the table
that follows. 

Page 199

MultiVOIP User Guide Technical Configuration (Analog)
199
E&M Interface Parameter Definitions
Field Name Values Description
Interface E&M enables E&M functionality
Type Types 1-5.  Each
type can be 2-
wire or 4-wire.Refers to the type of E&M
interface being used.
Signal Dial Tone or
WinkWhen Dial Tone is selected, no
wink is required on the E lead
or M lead in the call initiation or
setup.
When Wink is selected, a wink
is required during call setup.
Wink Timer
(in ms)integer values,
in millisecondsThis...

Page 200

MultiVOIP User Guide Technical Configuration (Analog)
200
10.  Set SNMP Parameters (Remote Voip Management).  This dialog
box can be reached by pulldown menu, keyboard shortcut, or
sidebar.  To make the MultiVOIP controllable by a remote PC
running the MultiVoipManager software, check the “Enable SNMP
Agent” box on the SNMP Parameters screen.