Home > Motorola > Pager > Motorola Minitor 6 Manual

Motorola Minitor 6 Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Motorola Minitor 6 Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 249 Motorola manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							Pager Programming Software (PPS)27
    English
    •The pager monitors any activity on 
    both frequencies. If activity is 
    detected on either frequency, the 
    receiver will lock on to that frequency 
    until the transmission ends.
    Note: Neither frequency will have 
    monitoring precedence over the other.•When the pager is locked on to either 
    of the scanned frequencies, the pager 
    will sound an alert to the correct 
    address tones for that frequency and 
    start message storage. The pager will 
    turn the audio off according to the 
    current Reset mode. The receiver will 
    then resume the scan activity.
    •Priority Scan:•This mode allows you to monitor 
    traffic on two different frequencies. 
    •One frequency must be 
    preprogrammed as a priority 
    frequency; and the second frequency 
    can be preprogrammed as a 
    non-priority frequency. 
    Note: The priority frequency has 
    monitoring precedence over the 
    non-priority frequency. •If the receiver is in the Scan mode 
    and is monitoring frequency activity 
    on a non-priority frequency, the 
    receiver will scan back to the priority 
    frequency at programmed intervals. If 
    activity is detected on the priority 
    frequency the receiver will then lock 
    on to that frequency. Scanning is 
    stopped until the priority frequency 
    becomes inactive. 
    68009690001_.book  Page 27  Thursday, March 27, 2014  3:10 PM 
    						
    							Pager Programming Software (PPS)English28
    •At this time the receiver will resume 
    the priority scan activity. The pager 
    will only alert on the detection of alert 
    tones on the priority frequency. The 
    pager will then turn the audio off 
    according to the current Reset mode. 
    Address detection is turned off for the 
    non-priority frequency.
    •Silent Scan:•This mode allows you to monitor 
    traffic on two different frequencies.
    Note: Neither frequency will have 
    monitoring precedence over the other.•The receiver alternately scans the two 
    frequencies and the audio remains 
    turned off. When a page is detected, 
    the pager generates a page alert and 
    performs message storage.•Upon receiving a page, the audio will 
    turn on immediately after the page alert (enabling the carrier squelch 
    operation). The pager will then turn 
    the audio off according to the current 
    Reset mode. The receiver will then 
    resume the silent scan activity.
    •Disabled:•This mode allows you to disable a 
    Function Switch position. When 
    programmed, the pager will play a low 
    frequency tone when switching the 
    channel knob to this position.
    Alert Type
    This option allows you to set the type of 
    alerts to be activated when the pager is 
    powered up or when there is an incoming 
    page.
    There are three different alert types 
    available.
    •Tone: The pager plays a tone.
    68009690001_.book  Page 28  Thursday, March 27, 2014  3:10 PM 
    						
    							Pager Programming Software (PPS)29
    English
    •Vibrate: The pager vibrates.•To n e  &  V i b r a t e: The pager plays a tone 
    and vibrates simultaneously.
    Note: While the pager is in the Amplifier 
    Charger it will not alert if it is set to vibrate.
    Announcements
    When the Function Switch announcements 
    are enabled, you can set the type of 
    announcements to be played. These 
    announcements are played when the pager 
    is powered up or when the Function Switch 
    is moved to a new position.There are three different announcement 
    types available.
    •Standard: Announces the mode, 
    frequency number, and alert type that 
    are programmed for the current switch 
    position. For priority scan, the first 
    frequency announced is the priority 
    channel.•Enhanced: In addition to the Standard 
    announcement, announces On/Off Duty, 
    Push-To-Listen, Priority Alert, and 
    Privacy when programmed for the 
    current switch position.•Custom: Plays the custom function 
    switch announcements stored. You can 
    store up to eight different custom 
    announcements in the pager.
    68009690001_.book  Page 29  Thursday, March 27, 2014  3:10 PM 
    						
    							Pager Programming Software (PPS)English30
    Enable On/Off Duty
    This option is available for Selective Call 
    and Silent Scan modes only. It allows you 
    to program a specific address as Off Duty, 
    thereby ignoring that address. By clicking 
    on the checkbox, the on or off selection 
    gets enabled in the corresponding channel 
    tab.
    Note: While programming the addressed 
    as on or off for any channel position, at 
    least one address must be programmed as 
    On Duty.Push-To-Listen
    This option is available for Selective Call 
    and Silent Scan modes only. When this 
    option is enabled, after the page alerts, you 
    must hold down the Reset button to 
    monitor the incoming message. This option 
    does not affect the storing voice process.
    The Alert Type is set to vibrate by default. It 
    is compatible with the Off Duty mode (if the 
    call address is set for either On or Off 
    Duty).68009690001_.book  Page 30  Thursday, March 27, 2014  3:10 PM 
    						
    							Pager Programming Software (PPS)31
    English
    Channel Options
    You can program up to five different 
    receiving frequencies and their 
    corresponding parameters like bandwidth, 
    tone system, and coding option.
    Channel Bandwidth
    The pager can operate on 12.5 KHz 
    Channel Spacing (Narrowband) or 25 KHz 
    Channel Spacing (Wideband).Reset Function
    Sets the method to reset the pager after 
    receiving a page. There are eight different 
    reset functions available.
    •Automatic: Resets the pager when 
    carrier drops.•Delayed: Waits momentarily before 
    checking for carrier drop to reset the 
    pager.•Muted Delayed: Waits momentarily 
    before checking for carrier drop to reset 
    the pager. During the momentary wait 
    period mutes the speaker and stored 
    voice recording during carrier drop. •Revert: Reverts to Monitor mode after 
    receiving a Selective Call page.
    68009690001_.book  Page 31  Thursday, March 27, 2014  3:10 PM 
    						
    							Pager Programming Software (PPS)English32
    •Delayed Revert: Waits momentarily 
    before checking for carrier drop and 
    then reverts to Monitor mode.•Muted Delayed Revert: Waits 
    momentarily before checking for carrier 
    drop and then reverts to Monitor mode. 
    During the momentary wait period 
    mutes the speaker and stored voice 
    recording during carrier drop. •Time-out: Resets the pager after a 
    preprogrammed amount of time.•Manual: Audio remains turned on until 
    the Reset button is pressed while in 
    Selective Call and Silent Scan modes. Audible and Vibrate Alerts
    For each call address, determines which 
    alert tone to play and which pattern to 
    vibrate upon receipt of a page. 
    For each channel, the pager can support 
    up to 15 call addresses (10 individual and 5 
    group). Each call address can be 
    programmed to alert with different tone and 
    vibrate patterns.
    •Tone Alert: Select from 10 
    pre-programmed tones and up to 5 
    custom audio alerts.•Vibrate Alert: Select either a 
    continuous or pulsed vibrate pattern.
    Note: Whether the pager provides an 
    audible, vibrate, or combined audible/
    vibrate alert depends upon the Alert Type 
    Function Switch option setting.
    68009690001_.book  Page 32  Thursday, March 27, 2014  3:10 PM 
    						
    							Stored Voice Features and Controls33
    English
    Stored Voice Features 
    and ControlsThe pager can store at least 8 minutes of 
    voice messages. Messages are stored 
    according to their length. If preferred, the 
    pager can be programmed to store 
    messages in fixed lengths of 30, 60, or 120 
    seconds instead. Minitor VI provides a list 
    of controls for stored message 
    management – fast forward, rewind, skip to 
    next, return to previous, lock, unlock, and 
    delete all.
    Stored Voice OperationThe message is stored only when a 
    properly encoded message is received. 
    Note: Other communications monitored on 
    the channel that do not alert your pager are 
    not stored.
    The message recording cycle is complete 
    under any of the following conditions:•When the Stored Voice Duration for the 
    message is reached.•When the squelch circuit no longer 
    detects carrier signal and no Reset 
    Function timer is active.•When the Delayed Reset cycle is 
    complete and carrier is no longer 
    detected.
    68009690001_.book  Page 33  Thursday, March 27, 2014  3:10 PM 
    						
    							Stored Voice Features and ControlsEnglish34
    • When the Timed-out Reset cycle is 
    complete.
    Note: If channel traffic occurs after the 
    page and message, and before carrier 
    signal is lost, that will also be stored in 
    memory. Stored Message ManagementYour pager offers extended capability to 
    manage the stored messages. There are 
    three multifunction buttons available on the 
    front side of device for message 
    management.Playback 
    ButtonPress the Playback button to 
    playback a particular message 
    stored in the memory of your 
    pager. This is a 
    multi-functional button offering 
    different functionalities.
    •Press in Standby mode to 
    play back the most recent 
    message.•Press in Playback mode to 
    stop the message 
    playback.•Press and hold in Standby 
    mode to play back locked 
    messages.•Press and hold in Playback 
    mode to lock or unlock the 
    message.
    68009690001_.book  Page 34  Thursday, March 27, 2014  3:10 PM 
    						
    							Stored Voice Features and Controls35
    English
    Note: Press and hold the Fast Forward 
    and Rewind buttons simultaneously to 
    delete all stored unlocked messages. You 
    need to unlock a locked message before 
    you can delete it. Fast 
    Forward 
    ButtonPress the Fast Forward button 
    to skip to the next message or 
    to fast forward the current 
    message.
    •Press to skip to the next 
    message.•Press and hold to fast 
    forward the current 
    message.Rewind 
    ButtonPress the Rewind button to 
    return to the previous 
    message or to rewind the 
    current message being 
    played.
    •Press to return to the 
    previous message.•Press and hold to rewind 
    the current message.
    68009690001_.book  Page 35  Thursday, March 27, 2014  3:10 PM 
    						
    							Cleaning Your PagerEnglish36
    Cleaning Your PagerTo clean smudges and grime from the 
    exterior of your pager, use a soft, 
    non-abrasive cloth moistened in a mild 
    soap and water solution. Use a second 
    cloth moistened in clean water to wipe the 
    surface clean. Do not immerse in water. Do 
    not use alcohol or other cleaning solutions.Repair and MaintenanceYour pager, properly handled, will provide 
    quality service for years. However, should 
    it ever require service, call 1-800-548-9954 
    for instructions.
    AccessoriesMotorola offers several accessories to 
    increase communications efficiently and 
    provide many unique benefits. Consult 
    your Motorola sales representative for a 
    complete list of accessories, prices, and 
    applications.•Desktop Battery Charger•Desktop Battery Charger Amplifier with 
    Antenna and Relay•Nylon Carrying Case•Alkaline Battery Tray (non-UL models 
    only)
    68009690001_.book  Page 36  Thursday, March 27, 2014  3:10 PM 
    						
    All Motorola manuals Comments (0)