Home > Motorola > Pager > Motorola Minitor 6 Manual

Motorola Minitor 6 Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Motorola Minitor 6 Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 249 Motorola manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							Identifying the Pager Controls17
    English
    Scan (5 Channel Models Only)
    Each function mode can scan two channels 
    as long as the pager is programmed with 
    two or more channels.
    Reset Button
     The Reset Button is multifunctional.•Condition: After receiving an alert (and 
    the Reset function is not programmed 
    for Automatic Reset or the Delayed 
    Reset timer has not expired)
    Action: Press the Reset button to return 
    your pager to the Standby mode.
    •Condition: Privacy option is not 
    enabled
    Action: Press and hold the Reset 
    button to place the pager in open 
    squelch Monitor mode.•Condition: Battery indication
    Action: To view the battery level, press 
    and release the Reset button.•Condition: Push-to-Listen enabled
    Action: After receiving an alert, press 
    the Reset button to listen to an incoming 
    message.•Condition: Critically low battery alert 
    reminder
    Action: To disable the automatic critical 
    battery alert reminder, press and 
    release the Reset button while the 
    reminder is in progress.
    68009690001_.book  Page 17  Thursday, March 27, 2014  3:10 PM 
    						
    							Identifying the Pager ControlsEnglish18
    Conditioning Your Pager For Operation
    Follow the procedures described next to 
    condition your pager for operation.1.
    Set the Function Switch to a tone-alert 
    position and power up the pager. You 
    hear four short beeps. The red and 
    yellow LED blinks indicating that the device has been powered up.
    2.
    Set the Function Switch to a monitor position.
    3.
    Listen for a transmission and adjust the 
    volume control to a comfortable listening level.
    4.
    If no transmission is heard, hold down 
    the Reset button and adjust the 
    background noise to a comfortable 
    listening level. If required, adjust the 
    volume level when a voice signal is present.
    5.
    Set the Function Switch to the desired 
    operating mode (e.g. Selective Call, 
    Monitor, or Scan with tone and/or vibrate alert, etc.).
    68009690001_.book  Page 18  Thursday, March 27, 2014  3:10 PM 
    						
    							Pager Programming Software (PPS)19
    English
    Pager Programming 
    Software (PPS) Take a moment to familiarize yourself with 
    the available PPS programmable options:
    Stored Voice Duration . . . . . . . . . . page 20
    Announcements Type . . . . . . . . . . page 20
    Function Switch Announcements  . page 21
    Battery Level Announcement  . . . . page 21
    Fixed Volume Page Alert . . . . . . . . page 22
    Priority Scan Time . . . . . . . . . . . . . page 22
    Page Alert Duration . . . . . . . . . . . . page 23
    Unread Message Reminder  . . . . . page 23
    Priority Tone Alert  . . . . . . . . . . . . . page 24
    Privacy. . . . . . . . . . . . . . . . . . . . . . page 24
    Always On . . . . . . . . . . . . . . . . . . . page 25
    Function Switch Options . . . . . . . . page 25Note: If your model does not support any of 
    the features mentioned above, contact a 
    Motorola authorized paging system dealer 
    or call 1-800-548-9954 for more 
    information or for the addition of these 
    features.68009690001_.book  Page 19  Thursday, March 27, 2014  3:10 PM 
    						
    							Pager Programming Software (PPS)English20
    Stored Voice Duration
    This feature allows you to limit the length of 
    an incoming message to be stored. 
    Note: A shorter message length allows for 
    more number of total messages stored.
    There are five options available. •15 seconds: First 15 seconds of a 
    message is stored. •30 seconds: First 30 seconds of a 
    message is stored.•60 seconds: First 60 seconds of a 
    message is stored.•120 seconds: First 120 seconds of a 
    message is stored. 
    •Dynamic: Complete message is stored 
    regardless of the length of the message 
    (depending upon the memory 
    available).Announcements Type
    This feature allows you to select the voice 
    type for announcements.
    There are two options available.•Male: All announcements will be played 
    in the male voice.•Female: All announcements will be 
    played in the female voice.
    68009690001_.book  Page 20  Thursday, March 27, 2014  3:10 PM 
    						
    							Pager Programming Software (PPS)21
    English Function Switch 
    Announcements
    This feature allows you to enable or disable 
    the voice announcements when the pager 
    is powered up or when the Function Switch 
    is moved to a new position.
    There are four options available.•On: Voice announcements enabled.•On Reset Only: Voice announcements 
    enabled only when Reset button is 
    released.•On & On Reset: Voice announcements 
    also enabled when Reset button is 
    released.•Off: Voice announcements disabled.
    Battery Level Announcement
    This feature allows you to enable or disable 
    the voice announcements for the battery 
    level when you press and release the 
    Reset button.
    There are two options available.•On: Voice announcements enabled.•Off: Voice announcements disabled.
    68009690001_.book  Page 21  Thursday, March 27, 2014  3:10 PM 
    						
    							Pager Programming Software (PPS)English22
    Fixed Volume Page Alert
    This feature allows you to fix the page alert 
    volume level at its loudest setting.
    There are two options available.•On: The page alert volume level is fixed 
    at the maximum. Turning the On/Off/
    Volume Control Knob changes only the 
    voice message volume level.•Off: Turning the On/Off/Volume Control 
    Knob changes the voice message and 
    the page alert volume level.
    Priority Scan Time
    This feature allows you to set a duration for 
    the pager to wait before scanning the 
    priority channels. 
    Note: This option is enabled only when one 
    of the Function Switch positions is 
    configured for priority scan.
    The range of the Priority Scan Time is 
    0.64 seconds to 2.04 seconds; the default 
    is 0.512 seconds.
    Note: If the priority scan time is set to more 
    than 0.512 seconds, you may miss an 
    incoming message.
    68009690001_.book  Page 22  Thursday, March 27, 2014  3:10 PM 
    						
    							Pager Programming Software (PPS)23
    English
    Page Alert Duration
    This feature allows you to set the duration 
    of page alerts. 
    There are two options available.•Fixed: You can set the duration to a 
    fixed value between 0.5 seconds to 
    2 minutes.•Standard: The alert will last for a 
    standard duration of two tones.
    Note: If the duration is fixed and is longer 
    than the duration of the second pager 
    activation tone, you may miss either part of 
    the message or the entire message 
    depending on the message length.
    Unread Message Reminder
    This feature allows you to enable or disable 
    the reminder that there is one or more 
    unread messages in the pager. 
    There are two options available.•On: Unread message reminder 
    enabled.•Off: Unread message reminder 
    disabled.
    68009690001_.book  Page 23  Thursday, March 27, 2014  3:10 PM 
    						
    							Pager Programming Software (PPS)English24
    Priority Tone Alert
    This feature allows you to override the 
    vibrate settings of the Function Switch for 
    Call Address 1 on Frequency 1 to always 
    sound a tone alert instead.
    There are two options available.•On: The pager sounds a tone alert 
    instead of vibrating to indicate an 
    incoming message - even when the 
    alert type is set as vibrate.•Off: The pager vibrates to indicate an 
    incoming message - when the alert type 
    is set as vibrate.
    Privacy
    This feature allows you to disable the 
    ability to monitor the channel when you 
    press and hold the Reset button - unless 
    Push-To-Listen is enabled for silent scan or 
    selective call modes.
    There are two options available.•On: Pressing and holding the Reset 
    button does not place the pager in 
    monitor mode.•Off: Pressing and holding the Reset 
    button places the pager in monitor 
    mode.
    68009690001_.book  Page 24  Thursday, March 27, 2014  3:10 PM 
    						
    							Pager Programming Software (PPS)25
    English
    Always On
    This feature allows you to keep the pager 
    on regardless of the On/Off/Volume Control 
    Knob position.
    There are two options available:•On: The pager will remain powered up - 
    even when the On/Off/Volume Control 
    Knob is switched to off position•Off: The pager turns off when the On/
    Off/Volume Control Knob is switched to 
    off position.
    Note: While Always On is enabled, the 
    pager needs to be power cycled after you 
    reattach the battery.
    Function Switch Options
    There are eight different Function Switch 
    positions available, labeled from A to H. 
    The following options can be programmed 
    for each of the Function Switch positions.
    Mode
    This option allows you to select the mode 
    of operation for different Function Switch 
    positions.
    There are six different modes available.•Selective Call:•This mode allows you to detect 
    two-tone and long-tone pages. 
    68009690001_.book  Page 25  Thursday, March 27, 2014  3:10 PM 
    						
    							Pager Programming Software (PPS)English26
    •Only one frequency can be monitored 
    for paging tones at any given time. 
    When a page is detected, the pager 
    generates a page alert and stores the 
    message. 
    Note: The page alert may be an audible or 
    a vibrate - depending on the Function 
    Switch position.•In Selective Call mode, the audio will 
    remain turned off until a page is 
    received, where upon your pager will 
    alert, indicating the carrier squelch 
    operation is enabled. The pager will 
    then turn the audio off according to 
    the current Reset mode.•Additional programmable options are 
    Off Duty, Priority Tone Alert, 
    Push-To-Listen, and Privacy mode.Note: Selective Call can be set for up to 
    five different frequencies, labeled as F1, 
    F2, F3, F4, and F5.
    •Monitor:•This mode allows you to monitor 
    activity on a programmed frequency 
    (carrier squelch operation). •Only one frequency can be monitored 
    at a time. When a page is detected, 
    the pager generates a page alert and 
    stores the message.
    Note: Monitor can be set for up to 5 
    different frequencies, labeled as F1, F2, 
    F3, F4, and F5.
    •Probability Scan:•This mode allows you to monitor 
    traffic on two different frequencies. 
    68009690001_.book  Page 26  Thursday, March 27, 2014  3:10 PM 
    						
    All Motorola manuals Comments (0)

    Related Manuals for Motorola Minitor 6 Manual