Page 121
Configurating MESA-Net Async Hardware and Links on configuritig these parameters, refer to CP 5712 in the procedural part of this chapter. Baud Rate MESA-Net software transmits and receives data at 300 to 57600 baud on each link. Total throughput per system varies by Series 6 server model. For highest throughput, use the Serial 16132 Card in the Centigram server. High baud rates minimize transmission costs, but public switched networks may not be able to support high speed transmissions. The...
Page 122
Configurating MESA-Net Async Hardware and Links The send ftil count and receive fail count are reset to zero each time an error-free block of data is transmitted. The default: limit for send fail count and receive fail count is 7. This means that if there are 7 consecutive errors on a single block of data, the line is too “dirty” for successful communication. The node then executes the disconnect actions of the hardware type associated with the link, which breaks the connection. The number of...
Page 123
Configurating MESA-Net Async Hardware and Links send Timeout A sending node expects a confirmation message back from a receiving node every time it sends a packet of data. The sending system does not wait for confirmation of receipt of one packet before sending another packet (which would be too inefficient), but it does expect confirmation messages to be sent in a timely manner. The resend timer tracks the time between confirmation messages. The resend timer is started immediately after the first...
Page 124
Configurating MESA-Net Async Hardware and Links Assignments 1 I 1 Link Number I Device Number Serial Port Number I q I 57600 I a 1200 I 38400 4800 300 / Data Bits: 7a Stop Bits: a 1 2 I Even Odd Space I 1 Send Fail Count Receive Fail Count q 7 I (l-255) (l-255) I 1 Data Receive Timeout i i Resend Timeout q 60 seconds-“’ I 1 Node Inactivity Timeout 6o seconds cl I igure 4-3 Sample Links o&sheet hanging the Answer or riginate link Assignment In the default configuration for...
Page 125
P Configurating MESA-Net Async Hardware and Links can configure both links as answer links. Since MESA-Net operates in full-duplex mode, as other nodes call in, outgoing messages are sent to that node during the same call. Parameters Once you have created a link, you can modify any of the parameters by using the Modify Link Menu while the system is processing calls. The changes you make take effect when the next call is made. For step-by-step instructions on modifying a link, see CP 5714 in the...
Page 126
Configurating MESA-Net Async Hardware and Links For step-by-step instructions on inquiring about a link, see Cl? 5716 in the procedural part of this chapter. 4-15
Page 128
Device Number cl Name jI Answer Actions String Timeout Command String Timeout Originate Actions Command 1 2 3 4 5 4 7 8 9 10 11 12 13 14 15 16 17 18 19 20 6 7 9 10 Disconnect Call Actions Command 1 2 Parameter Timeout i 5 “u 6. 7 Line Drop Signal (circle one) DTR RTS BREAK CTS DSR RING CD
Page 130
Serial Port I Assignments j I / Link Number c Device Number cl Serial Port Number cl 1 Baud Rate: Parity: I 64000 19200 2400 None Mark I 57600 9600 1200 Even I Space I 38400 4800 300 Odd i Data Bits: 7 8 Stop Bits: 0 1 2 Flow Control: Enabled Disabled I 1 Send Fail Count q Receive Fail Count I (l-255) (l-255) / Data Receive Timeout 0 seconds i i Resend Timeout c seconds ” I / Node Inactivity Timeout c seconds