Page 291
Appendix B - Blank CDE Forms FFORM 09 - “EXPAND PKWSUBFORM Programmable Key Module Lines Sheet of PKM/KEY TYPE DIR RING 1 SEC 1 DSS EXJ NUM TRK NUM WBEL I 01 1 Prime 1 In/Out 1 lmmed 1 No 1 No 1 I I I 03 04 05 06 07 I I I I I I I I oq 09 10 11 12 13 14 15 16 t 17 18 19 20 21 22 29 30 31 32 The PKM is only associated with SUPERSE~470, SUERSE~420, and SUPERSET telephones. March 1997 issue 1 Revision 0 B-19
Page 292
Customer Data Entry FORM 10 - PICKUP GROUPS sheet of GROUP NUMBER (I- 50): EXTENSION NUMBERS I GROUP NUMBER (1 - 50): GROUP NUMBER (I - 50): B-20 Issue 1 Revision 0 March 1997
Page 293
Appendix B - Blank CDE Forms FORM II - DATA CIRCUIT DESCRIPTORS DESCRIPTOR NUMBER OF DATA CIRCUITS ASSIGNED l COMMENTS 1 12 13 17 18 19 20 21 22 23 24 25 *This field is automatically updated by the system based on entries in Form 12. 1 March 1997 Issue 1 Revision 0 B-21
Page 294
Customer Data Entry DATA CIRCUIT DESCRIPTOR Ol=WOlVS ‘Select Option” Subform of Form I I 1 DATA CIRCUIT DESCRIPTOR NUMBER (1 - 25) OPTION NAME 1 -’ i-21 -3 l-4 l-5 1-6 l-7 l-8 l-9 I-0 Session Inactivity Disconnect Timer 0 - 255 minutes Guard Timer 0 - 99 seconds Minimum Baud Rate 110,150,300,600, 1200,2400,4800,9600 or 19.2K Default Baud Rate 110,150,300,600,1200,2400,4800,9600 or 19.2K Maximum Baud Rate 110, 150,300,600,1200,2400,4800,9600 or 19.2K Always Use Default Baud Rate When Called...
Page 295
Appendix B - Blank CDE Forms DATA CIRCUIT DESCRIPTOR NUMBER (1 - 25) OPTION NAME ASYNC: XON Character 0 -127, Decimal value of ASCII code ASYNC: XOFF Character 0 -127, Decimal value of ASCII code ASYNC: Break Key Function SYS ATT or TRANSPARENT ASYNC: PBX Attention Character 0 -127, Decimal value of ASCII code ASYNC: Parity ODD, EVEN, NONE, SPACE or MARK ASYNC: Character Length 7 or 8, 8 implies *no parity” ASYNC: Number of Stop Bits 1 or2 -1 -2 -3 -4 -5 -6 -7 -a -9 -0 ASYNC: Autobaud to...
Page 297
Appendix B - Blank CDE Forms FORM 13 - TRUNK CIRCUIT DESCRIPTORS DESCRIPTOR TRUNK TYPE COMMENTS 1 I 2 I 3 4 I 5 I 6 I 7 8 9 10 11 12 13 14 15 16 17 18 19 I 20 I I I 21 I 23 I 24 I 25 I March 1997 Issue 1 Revision 0 B-25
Page 298
Customer Data Entry 4Circuit CO/4-Circuit DISA Tanks ‘Select Option” Subfotm of Form 13 sheet of 4-CIRCUIT CO TRUNK and TRUNK CIRCUIT DESCRIPTOR NUMBER (1 - 25) 4-CIRCUITDISATRUNKOPTIONS Page 1 of 11 B-26 Issue 1 Revision 0 March 1997
Page 299
Appendix B - Blank CDE Forms 6-Circuit CO/6-Circuit DISA Tanks ‘Select Optiod Subfom of Form 13 Sheet of Page I of 1 March 1997 Issue 1 Revision 0 B-27
Page 300
Customer Data Entry E&M Module/ E&M Module USA links ttSelect Option” Subfom of Form 13 Sheet of E&M MODULE and TRUNK CIRCUIT DESCRIPTOR NUMBER- E&M MODULE DISA OPTIONS Outgoing Start Type Outpulse Delay Timer 100 - 2000 ms (100 ms inc) Flash Timer 200 - 700 ms (100 ms inc) Flash Type LOOP FLASH or RING GROUND Flash Over Trunk YES or NO Interdigit Timer 300 - 800 ms (100 ms inc) Wait For Delay Timer 300 - 5000 ms (100 ms inc) Remote End is a Satellite YES or NO Remote End is a Satellite...