Page 281

Features 
When a recording is playing for ACD, Automatic Attendant Overflow, and 
Automated Attendant, the Recording Message Length Timer (programmed 
on the recording group) applies. When the timer expires and the recording 
is still playing, the system terminates the recording. For some devices this 
acts as a safety timer for recording devices that fail to terminate their 
recording. For tape based recording devices, this allows the system to not 
play the dead time at the end of the tape. 
When an...

Page 282

Features Description 
Option 404 (Recording 
Failure to Hangup Timer) in the COS of the recording 
hunt group members. 
Since some RADs won’t answer calls that use discriminating ringing 
(non-standard ringing), ensure that COS Option 809 (Standard Ring 
Applies) is enabled in the COS of the incoming trunks. 
See CDE Form 77cMnrGroupsjfor details on programming the hunt group 
itself. 
Operation Not applicable. 
Recall 
Description 
The recall feature ensures that calls do not remain unanswered or on...

Page 283

Features 
Setting Up the Recall Point to extensions 
Extensions only affect the recall point of trunk calls when the trunk is 
answered (this includes answering calls via features such as Auto-Answer, 
directed pickup or TAFAS). The recall point is only set to the answering 
extension if the trunk call is not a serial trunk and the trunk has not had a 
recall point set up already. If the extension is a subattendant, and the trunk 
is not a serial call trunk, then the trunk recall point is changed even if...

Page 284

Features Description 
. 
if the recall point is set up and is 
busy, and if recalling from ringing, then 
the Recall No Answer Timer is started again. Otherwise, recall is 
attempted again after IO seconds. 
Conditions The following conditions apply to this feature: 
2-244 
l Ringing an extension from a hold timeout for SU/?!%SE~telephones 
or industry-standard telephones that are idle or have Do Not Disturb 
activated is handled as a recall after a ring no-answer timeout. 
l Unlike a reroute point, a...

Page 285

Features 
Programming 
Operation 
l See Attendant and Subattendant l-/old Positions and Hold for details on 
Hold Timeout handling. 
l A console never recalls to any other device, 
l A call recalls to extensions and consoles through a recall point. Recall 
to other device types must use features available through the Call 
Rerouting table. 
l When a SU/?E/?SE~teiephone answers a call on a non-prime line, the 
recall point for the caller, if it is altered, is set to the answering 
SUPERSET 
telephone and...

Page 286

Features Description 
Reminder 
Description 
Conditions 
Programming 
Operation 
2-246 Extension users can program their telephones to provide a single ringing 
burst at a particular time within a 24-hour period. This feature acts as a 
reminder for appointments, meetings, etc. 
Do 
Not Disturb has no effect on the Reminder feature. 
You can only program an extension with one reminder at a time, i.e., you 
cannot program an extension with multiple reminders. 
A reminder will occur each day at the...

Page 287

Features 
To display the current reminder setting: 
l Press SUPERKEY. 
l Press the NO softkey until TIMED REMINDER? appears in the display. 
l Press the YES softkey. The current reminder time is displayed. 
l Press SUPERKEY to return to normal display 
March 1997 
To cancel a reminder before it occurs: 
l Press SUPERKEY. 
l Press the NO softkey until TIMED REMINDER? appears in the display. 
l Press the YES softkey. The current reminder time is displayed. 
l Press the CANCEL softkey. REMINDER CANCEL...

Page 288

Features Description 
To display the current reminder setting: 
l Press the SUPERKEY. 
l Find and press the REMINDER softkey; the current reminder time is 
displayed. 
l Press the SUPERKEY to return to normal display. 
To cancel a reminder before it occurs: 
l Press the SUPERKEY. 
l Press the REMINDER softkey. The current reminder time is displayed. 
l Press the CANCEL softkey. 
Resale Package 
Description 
Conditions 
Programming 
Operation 
2-248 The Resale Package is a method of offering the system’s...

Page 289

Features 
Ringer Control 
Description You can adjust the ringer in a SU/?E/XXTteiephone or attendant console. 
Conditions 
l Attendant console users can adjust the ringer volume. 
l SUPERSET 401+, SUPERSET 420, and SUPERSET 430 telephone 
users can adjust both the ringer volume and the ringer pitch. 
Programming None. 
Operation To adjust ringer volume: 
SUPERSET 401+ and SUPERSET 410 Telephones: 
l While the set is ringing, press the VOL I’ and VOL J keys to increase 
and decrease the ringer volume....

Page 290

Features Description 
SUPERSET 420 telephones: 
Press SUPERKEY. 
Press the NO softkey until RINGER ADJUST? appears in the display. 
Press the YES softkey. 
ADJUST PITCH? appears in the display. 
Press the YES softkey. 
Press the VOL ? and VOL J keys repeatedly to increase and decrease 
the pitch. 
Press SUPERKEY to exit. 
SUPERSET 43U telephones: 
l Press SUPERKEY. 
l Press the MORE softkey. 
l Press the RING ADJUST softkey. 
l Press the RINGER PITCH softkey. 
l Press the VOL I’ and VOL 4 keys repeatedly...