Page 611

SECTION MITL9109-094-320-NACHART 5-15
ATTENDANT DIRECT TRUNK SELECT
StepActionVerify
1Press the FUNCTION key.Function softkeys are displayed.
2Press ATT FUNCTIONSof-tkey prompts change.
softkey.
3Press TRUNKS softkey.Attendant Console LCD display responds
by displaying the message:
Enter Trunk Number:-
4Enter trunk number.Digits are displayed on LCD as they are entered from the
telephony keypad. ATT ACCESS 
softkey is displayed.
5Press ATT ACCESS softkey. DST display shows selected trunk. If idle, trunk...

Page 612

System Test Procedures
CHART 5-17
ATTENDANT DISPLAY OF SUPERSET 4 TELEPHONE MESSAGES
StepActionVerify
1At a SUPERSET 4SUPERSET 4 LCD displays the message enabled.
telephone, enable a
message.
2Attendant dials theAttendant Console DST display shows the SUPERSET 4
SUPERSET 4 telephonetelephone data. The message enabled at the SUPERSET 4
directory number.telephone is displayed. The 
SUPERSET 4 telephone rings.
The Attendant Console receives 
Ringback Tone.
3Press the RELEASE key.Attendant Console returns to...

Page 613

SECTION MITL9109-094-320-NACHART 5-19
ATTENDANT NIGHT SWITCHING
StepActionVerify
1Press the FUNCTION key.Function softkey prompts are displayed.
2Press the NIGHT 1 softkey. Attendant Console returns to idle condition. System enters
Night Service 1. NIGHT 1 status flag is displayed on
Attendant Console LCD.
3Station “A” lifts handset,Night Service 1 night bells are rung. Station “A” receives
accesses an outgoing
Ringback Tone. Call does not appear at Attendant Console.
trunk, then accesses an
incoming...

Page 614

System Test Procedures
CHART 5-20SYSTEM IDENTIFIER
StepActionVerify
1Press the FUNCTION key.Function softkey prompts are displayed.
2Press the IDENTITYSystem identity (including sof-tvJVare release) and Attendant
SOFTKEY.Console LDN are displayed on Attendant Console LCD.
3Press the EXIT sof-tkey.Attendant Console returns to idle condition. Test
completed.
Page 89 

Page 615

SECTION MITL9109-094-320-NAMaintenance and Customer Data Entry Applications
5.04For this test, ensure that Maintenance and Customer Data Entry
Applications are not accessed by any Maintenance Terminal or
Attendant Console.
CHART 5-21
MAINTENANCE AND CUSTOMER DATA ENTRY APPLICATIONS
StepActionVerify
1Press the FUNCTION key.Function softkey prompts are displayed.
2Press the APPLICATIONAttendant Console LCD responds by displaying the
SOFTKEY.message:
Select An Application OR Press QUIT To Return
and...

Page 616

System Test Procedures
CHART 5-21 (CONT’D)
MAINTENANCE AND CUSTOMER DATA ENTRY APPLICATIONS‘ter,ActionIVerify
9Press ANSWER orStation “A” and Attendant Console are connected.
INTERNAL 
softkey.ANSWER LED is on. SRC display shows station “A” data.
IOPress FUNCTION key andAttendant Console display returns to Maintenance
APPLICATION 
softkey.Application, at point where Maintenance Application was
exited. Attendant Console was not logged out of
Maintenance Application.
11Press the RELEASE key.Attendant...

Page 617

SECTION MITL9109-094-320-NA
Page 92 

Page 618

System Test Procedures
6. CUSTOMER FEATURE TESTS
Class-of-Service Tests6.01The system has up to 50 Classes of Service. One station for
each Class of Service is selected. Each option for that station is
then 
t?sted.
1.Refer to the Class-of-Service Option forms. Make a note of
each of the COS Numbers.
2.Refer to the Station Assignment forms. Each station is assigned
a COS Number. For each COS Number, select a station number.
3.Again refer to the Class-of-Service Option forms. For each
station selected,...