Page 511
SECTION MITL9109-094-450-NATrunks -records activity of each trunk during the measurement period Trunk Number:List of all trunk numbers that were accessed. Peg in:Total number of times the trunk was seized for ,incoming.calls(maximum = 255). Usage in:Represents the usage (in Erlangs or CCS) for incoming calls on the trunk (maximum = 36 ccs). Peg Out:Total number of times the trunk was seized for an outgoing call on the trunk (maximum = 255). Usage Out:Represents the usage (in Erlangs or CCS) for outgoing...
Page 512
Traffic Measurement 3. TRAFFIC MEASUREMENT COMMANDS Maintenance Terminal and Console3.01The maintenance terminal or console is used to enter the data required to start traffic measurements, print measurements, monitor status, or change traffic measurement parameters. Refer to Section MITLS 109-094-35 1 -NA, RS-232 Maintenance Terminal, for instructions on using the terminal. At the maintenance terminal or console, select the MAINTENANCE application; from the MAINTENANCE main menu, select TRAFFIC MEAS...
Page 513
SECTION MITL91 O9-Q94-450-NAissued while traffic measurement is on; it must be STOPped and then restarted. STOP Command - This command causes two softkeys to become active, and pressing either selects. what is to be stopped. TRAFFRPT - stops the traffic measurement currently active. No report will be made of the incomplete collected data. PRINT - stops a printout being sent to the PRINTER port. Note:The STOP command will not stop an AUTOPRINT in progress; othe AUTOPRINT command must be set to OFF...
Page 514
Traffic Measurement Installation to meet the Traffic Measurement requirements con- sists of the following steps: Determine the required traffic parameters Determine the required output device Install the output device Program the traffic parameters and output device for this in- stallation. 4. INSTALLATION General4.01 1. 2. 3. 4.Connection Requirements, Local Printer 4.02Section MITL9109-094-200-NA, Shipping, Receiving and Instal- lation Information, details the installation of SX-200 DIGITAL PABX...
Page 516
Traffic Measurement 5. REPORTS General5.01The standard report provides a printed report of the data in the storage registers .(usually the measurements taken during the preceding period). The report includes headings which make the data easy to read. Three typical reports are printed following: 5.02Port size and system number are unique to each system; they are entered when the system is initally configured. The CHAN- NELS part of the printout is associated with the maximum port config- uration. Three...
Page 517
SECTION MITL9109-094-450-NASX-200 DIGITAL Generic 100X XXXP TRAFFIC REPORT SYSTEM nnn (CONT’D) I 27-NOV-869:oo to lo:oo -CHANNELS: Bay1 2 34 5 6 7 wCONSOLE: Directory Number 4900 4888Usage Max/Avl2.20 ccs 2/1249.60 ccs 4/ 62 3.00 ccs l/ 31 1.20 ccs 3/ 31 18.10 ccs 61 31 Usage Max/Avl17.60 ccs 2/12385.90 ccs 6/ 61 344.60 ccs 13/ 94 50.60 ccs 5/ 94 456.40 ccs 18/ 94 43.60 ccs 4/ 94 421.30 ccs 17/ 94 Usage 0.00 ccs 0.00 ccsCallsCalls Waiting Avg. Waiting AnsweredUsage Time (set) 00.00 ccs 0.00 00.00 ccs...
Page 518
Traffic Measurement TRUNKS: Number1 2 3 4 520 22 24 26 28 30 32 40 42Peg InUsage In 00.00ccs 00.00ccs 00.00ccs 00.00ccs 00.00ccs 55.10ccs 66.20ccs 61.20ccs 52.10ccs 54.40ccs 44.90ccs 40.90ccs 00.00ccs 00.00ccsPeg Out Usage Out 21.40 ccs 20.60 ccs 219.90 ccs 00.00 ccs 00.00 ccs 32.40 ccs 40.80 ccs 42.50 ccs 47.70 ccs 43.40 ccs 44.90 ccs 31.80 ccs 00.00 ccs 00.00 ccs 5.03The condensed report contains the data only, in decimal form. Register numbers, and assignments are known for each particu- lar software...
Page 519
SECTION MITL9109-094-450~NA 5.05The following table lists typical business traffic: Traffic TapeLight Medium HeavyNumber of PortsTraffic/Port(CCS)Total CCS 2501.4350 300 1.4420 350 1.4490 4001.4560 480 1.4672 250 3.c750 300 2.9870 350 2.91015 400 2.91160 480 2.91392 250 5.51375 300 5.41620 350 5.41890 .4005.42160 480 5.42592Page 16
Page 520
9 109-094-620-NA Issue 3 Revision 1 September, 1989 SX-2000 .DIGlTAL PABX ACD 7ELEMARKETERTM Application Package This practice describes the features, operation, and programming of the ACD TELEMAI?KETH?~” Application Package for the SX-2000 Digital Private Automatic Branch Exchange (PABX). Practice: 9 109-094-620-NA Issue:3 Revision:1 Date :September, 1989 Software Version: G1003 MR3 Yopyright 1989, MITEL Corporation. All rights reserved, ‘“Trademark of MITEL Corporation @Registered Trademark of MITEL...