Page 261
W-232 Maintenance Terminal Figure 6-l Example of LOGS READ Display 4:27 7-AUG-86 alarm status = MINOR SX-200 DIGITAL GENERIC 1001 480P/B46.5 19-AUG-1986 Logs 1985-JUN-21 15:33?01 ONS card failed at lot 02 01 00 00 OFF hook too long Error number = 17 1985-JUN-21 11:11:19 COV card failed at lot 03 03 00 00 SS4 unplugged Error number = 21 1985-JUN-2 1 09:23:25 Tot alarm went from No Alarm to MINOR Alarm level change due to Bay 03 trunks 1985-JUN-21 09:23:25 trunk card failed at lot 03 09 00 00...
Page 262
W-232 Maintenance Terminal DELETING LOG ENTRIES All Log Entries 6.06 To delete all of the maintenance log entries, press the following softkeys: DELETE ALL ENTER CONFIRM ENTER Newest Log Entries 6.07 To delete the newest user-defined number of maintenance log entries, press the following softkeys: DELETE NEWEST (enter the number of log entries to be deleted) ENTER Oldest Log Entries 6.08 To delete the oldest user-defined number of maintenance log entries, press the following softkeys:...
Page 263
RS-232 Maintenance Terminal Newest Log Entries 6.10 To print the newest user-defined number of maintenance log entries, press the following softkeys: PRINT NEWEST (enter the number of log entries to be printed) ENTER Oldest Log Entries 6.11 To print the oldest user-defined number of maintenance log entries, press the following softkeys: PRINT OLDEST (enter the number of log entries to be printed) ENTER In all cases, the system will echo the command into the Applications Area of the...
Page 264
RS-232 Maintenance Terminal entries. To initiate the automatic printing of logs, press the following softkeys: SET AUTOPRINT ON ENTER The system will echo the command into the Applications Area of the . screen. Page 6-616
Page 265
RS-232 Maintenance Terminal 7. DIAGNOSTIC FUNCTIONS 7.01 The Diagnostics Level of operation is a conglomeration of ac- tive testing-related commands that are designed to assist the maintenance user in ensuring that the SX-200@ DIGITAL PABX is op- erating at peak performance. The available commands allow the user to enable, schedule and initiate diagnostic testing, and to take equip- ment out of service, and return it to service. introduction 7.02 1. 2. 3. 4. 7.03 Four types of diagnostics...
Page 266
RS-232 Maintenance Terminal prioritized queues. The priority scheme of the queues is as follows, in ascending order: 8 Background diagnostic queue 8 Power-up diagnostic queue 8 Power-up diagnostic retry queue 8 Diagnostic second-chance queue 8 Diagnostic second-chance retry queue l User (directed diagnostic) queue. For further information on diagnostics, refer to Section MlTL9108-093-353-NA, General Maintenance Information. To access the diagnostic level commands, press the DIAGNOSTICS...
Page 267
- RS-232 Maintenance Terminal pressing the RETURN key after each one) ENTER For a Specific Extension 7.08 The user may enable power-up diagnostics for a specific ex- tension number by pressing the following softkeys: MORE-KEYS ENABLE-DIAG POWER-UP EXT-NUM (enter the required extension number, then press the RETURN key) ENTER For a Specific Device Type 7.09 The user may enable power-up diagnostics for a specific device type by pressing the foilowing softkeys: MORE-KEYS ENABLE-DIAG...
Page 268
RS-232 Maintenance Terminal DlSABLiNG POWER-UP DIAGNOSTICS For an Entire Bay 4.11 The user may disable power-up diagnostics for an entire bay by pressing the following softkeys: MORE-KEYS DISABLE-DIAG POWER-UP BAY/SLOT/CCT (enter the required bay number, then press the RETURN key four times) ENTER For an Entire Peripheral Card 7.12 The user may disable power-up diagnostics for an entire pe- ripheral card by pressing the following keys: MORE-KEYS DISABLE-DIAG POWER-UP BAY/SLOT/CCT...
Page 269
RS-232 Maintenance Terminal For a Specific Extension 7.14 The user may disable power-up diagnostics for a specific ex- tension number by pressing the following softkeys: MORE-KEYS DISABLE-DIAG POWER-UP EXT-NUM (enter the required extension number, then press the RETURN key) ENTER For a Specific Device Type 7.15 7.16 The user may disable power-up diagnostics for a specific de- vice type by pressing the following softkeys: MORE-KEYS DISABLE-DIAG POWER-UP DEVICE TYPE (press one of the...
Page 270
RS-232 Maintenance Terminal For an Entire Peripheral Card 7.18 The user may enable background diagnostics for an entire pe- ripheral card by pressing the following keys: MORE-KEYS DISABLE-DIAG POWER-UP BAY/SLOT/CCT (enter the required bay; press the RETURN key; enter the re- quired card slot number: press the RETURN key three times) ENTER For a Specific Circuit 7.19 The user may enable background diagnostics for a specific circuit by pressing the following softkeys: MORE-KEYS ENABLE-DIAG...