Page 271

RS-232 Maintenance Terminal 
7.22 In all cases, the system will echo the command into the Ap- 
plications Area of the screen. The user may verify that the 
particular background diagnostics have been enabled via the SHOW 
STATUS command (see paragraph 5.14). 
DISABLING BACKGROUND DIAGNOSTICS 
For an Entire Bay 
7.23 
The user may disable background diagnostics for an entire bay 
by pressing the following softkeys: 
MORE-KEYS 
DISABLE-DIAG 
BACKGROUND 
BAY/SLOT/CCT 
(enter the required bay number, then...

Page 272

RS-232 Maintenance Terminal 
For a Specific Extension 
7.26 The user may disable background diagnostics for a specific 
extension number by pressing the following softkeys: 
MORE-KEYS 
DISABLE-DIAG 
BACKGROUND 
EXT-NUM 
(enter the required extension number, then press the RETURN 
key) 
ENTER 
For a Specific Device Type 
7.27 The user may disable background diagnostics for a specific 
device type by pressing the following softkeys: 
MORE-KEYS 
DISABLE-DIAG 
BACKGROUND 
DEVICE TYPE 
(press one of the...

Page 273

RS-232 Maintenance Terminal 
On a Specific Extension 
7.31 To run a directed test on a specific extension number, press the 
following softkeys: 
TEST 
EXT-NUM 
(enter the required extension number, then press the RETURN 
key) 
ENTER 
On a Specific Device Type 
7.32 To run a directed test on a specific device type, press the 
following softkeys: 
TEST 
DEVICE TYPE 
(press one of the softkeys shown in Table 7-I) 
ENTER 
In all cases, the system will output the test results in the Applications 
Area of the...

Page 274

RS-232 Maintenance Terminal 
Specific Circuits 
7.35 To busy out a specific circuit, press the following softkeys: 
MORE-KEYS 
BUSY-OUT 
BAY/SLOT/CCT 
(enter the required bay, slot, circuit and sub-circuit numbers, 
pressing the RETURN key after each one) 
ENTER 
Specific Extensions 
7.36 To busy out a specific extension number, press the following 
softkeys: 
MORE-KEYS 
BUSY-OUT 
EXT-NUM 
(enter the required extension number, then press the RETURN 
key) 
ENTER 
7.37 In either case, the system will echo...

Page 275

RS-232 Maintenance Terminal 
EXT-NUM 
(enter the required extension number, then press the RETURN 
key) 
ENTER 
CLEARING SUPERSET@ ERROR COUNTER 
For Specific Circuits 
7.40 To clear the SUPERSET Error Counter for a specific SUPERSET 
circuit, press the following softkeys: 
CLEAR 
SSET-ERRORS 
BAY/SLOT/CCT 
(enter the required bay, slot, circuit and sub-circuit numbers, 
pressing the RETURN key after each one) 
ENTER 
Page 7-11  

Page 276

RS-232 Maintenance Terminal 
Figure 7-l Example of Directed TEST Display 
4:27 7-AUG-86 
alarm status = MINOR 
SX-200 DIGITAL GENERIC 1001 480P/B46.5 19-AUG-1986 Diagnostics 
TEST 02 01 03 ** 
TOTAL TESTS RUN = 1 TOTAL TESTS FAILED = 0 
PLID TESTED = 2 1 3 0 
Page 7-12  

Page 277

RS-232 Maintenance Terminal 
For Specific Extensions 
7.41 To clear the counter for a specific extension, press the follow- 
ing softkeys: 
-- CLEAR 
SSET-ERRORS 
EXT-NUM 
(enter the required extension number, then press the RETURN 
key) 
ENTER 
For All SUPERSET@ Sets 
7.42 To clear the entire SUPERSET error counter, press the following 
softkeys: 
CLEAR 
SSET-ERRORS 
ALL 
ENTER 
7.43 The user may verify the error counter clearing via the “SHOW 
SSET-ERRORS” command, which operates in the Diagnostics...

Page 278

RS-232 Maintenance Terminal 
8. OTHER MAINTENANCE TERMINAL APPLICATIONS 
Customer Data Entry (CDE) 
8.01 The RS-232 Maintenance Terminal is also the main device used 
for the programming of customer data. At the start of the login 
procedure, the user is queried to start either a Maintenance session or 
a CDE session (see paragraph 2.05). Only a VT-100 compatible terminal 
may be used for CDE. For further information on CDE, see Section 
MITLSI 08-093-210-NA, Customer Data Entry. 
Traffic Measurement...

Page 279

RS-232 Maintenance Terminal 
APPENDIX A 
USERNAME COMMAND PWWILEGES 
Al.01 The following Table lists all the command privileges of all of 
the valid username levels: 
TABLE Al-l 
USERNAME COMMAND PRIVILEGES 
1 COMMAND 1 Installer 1 Maintl 
I MaintZ 1 Supervisor I Attendant I 
I---- SET TIME 1x1 x I x I x I x I 
ISET DATE -1x1 x I x I x I x I 
SET PASSWORD X X X X 
X 
SET SPEED X X 
SET PRINT-DEV X X 
I I I I I 
SHOW DATE X x . X X X 
ISHOW TIME 
1x1 x I x I x I x I 
I ~~~~ 
SHOW DEVICE 1x1 x I x I x I x...

Page 280

RS-232 Maintenance Terminal 
TABLE Al-l (CONT’D) 
USERNAME COMMAND PRIVILEGES 
COMMAND 1 installer Maintl 1 Maint2 
I Supervisor 1 Attendant 
TRAFFIC SHOW 
Ix/ x I I x I I 
TRAFFIC PRINT X X X 
X X 
I 
TRAFFIC READ 
I x I 
TRAFFIC STOP 
EGS SET PRINT * X X X X 
X. 
X X 
LOGS SET AUTO X X 
I I I I 
LOGS READ 1x1 x I I I I 
LOGS PRINT 
STOP PRINT LOGS 
LOGS DELETE X X 
X X 
X X 
1 
I I I I 
SHOW ALARMS X 
SHOW CONFIG 
1x1 x I I I I 
SHOW STATUS 1x1 x I I I I 
SHOW SSET-ERRORS 1 X X I I I I 
SHOW...