RS-232 Maintenance Terminal 
BAY 1 SLOT 7 BAY 1 SLOT 56 
.J,g . . . . . . . . . 
JZ, . ..a. . . . . e.e... ‘..J,3 
J23.a 0 TEMP SENSE p, 
 ABC 
NOT USED 
0-a. Jl 
NOT USED  E4 (DGI 
0 
r - 
‘DISK DRIVE 
J319 $7  POWER 10  J17A 
PCM TO 
15 
I BAY 3 
20  
J17B 
25 PCM TO 
BAV 4 
30 
CONSOLE 
MAINTENANCE 
J29  PANEL 
e... 
J27 
T+R TEST LINE 
. e* 
J41 III25 
0 
ABC 
0 
0 
UPS ALARM UP 
El (EDG) 
8 
E2 (DO) 
0 
BAY 2 SLOT ‘I+2 BAV 1 SLOT 3+4 BAY 1 SLOT I+2 
NOT USEI 
0 D 
J: 
NOTE: J19 c LOCAL RS-232...

Page 224

RS-232 Maintenance Terminal 
3. MAINTENANCE COMMAND INPUT 
Maintenance Terminal Display 
3.01 The maintenance display screen is shown in Figure 3-l. There 
are five distinct and separate areas to the screen: 
1. Status Line : This occupies a single line above the bordered 
area, and displays the time and date, and the system alarm 
status. 
2. Header Line : This occupies the top line within the bordered 
area. It identifies the running software version, and its creation 
date. It also describes which...

Page 225

RS-232 Maintenance Terminal 
Incorrect Command Entry 
3.04 The SX-200’ DIGITAL user interface provides a comprehensive 
set of error messages to inform the user of incorrect command 
entry. While the softkey-oriented command input interface minimizes 
the chance of incorrect command entry, the error messages provide 
concise descriptions of the input error. A summary of the error mes- 
sages with descriptions may be found in Appendix B. 
Non-VT-100 Compatible Terminal Use 
3.05 When using a terminal not...

Page 226

RS-232 Maintenance Terminal 
Wiid Card Characters 
3.07 Wild card characters may be used to perform some command- 
initiated functions on a range of devices. This is done simply by 
not specifying circuit location numbers when prompted (pressing only 
the RETURN key). For example, entering. Bay 1, but not specifying the 
slot, circuit or sub-circuit would translate to “all circuits on all cards in 
Bay 1”. Note that this does not apply to all commands; refer to the 
individual command descriptions....

Page 227

RS-232 Maintenance Terminal 
Figure 3-1 Top Level Maintenance Terminal Screen Layout 
427 7-AUG-86 alarm status = NO ALARM 
SX-200 DIGITAL GENERIC 1001 480P/B46.5 19-AUG-1986 
Main menu 
Page 3-4/4  

Page 228

RS-232 Maintenance Terminal 
4. SYSTEM LEVEL FUNCTIONS 
e 
Introduction 
4.01 The System Level of operation contains a conglomeration of 
commands that are not necessarily maintenance applications, 
but affect maintenance in some way (e.g., the setting of time, date, and 
passwords). To access the system level commands, press the SYSTEM 
softkey. All of the following operations are done while in the System 
-- 
Level. 
Time Setting and Verification 
4.02 The system time-of-day may be set and verified...

Page 229

RS-232 Maintenance Terminal 
After entering a valid date, the user may implement the new date by 
pressing the ENTER softkey, or cancel the new date by pressing the 
CANCEL softkey. 
The user may verify the date by pressing the following softkeys: 
SHOW 
DATE 
ENTER 
Terminal/Printer Port Status Report 
4.04 The maintenance u’ser may view the current data characteristics 
of the SX-200@ DIGITAL PABX maintenance terminal and printer 
ports. Information in the reports includes communication speed (baud...

Page 230

RS-232 Maintenance Terminal 
Figure 4-l Terminal/Printer Port Status Report 
4:27 7-AUG-86 alarm status = NO ALARM 
SX-200 DIGITAL GENERIC 1001 48OP/B46.5 19-AUG-1986 System 
SHOW DEVICE PORT : MAINTENANCE 
SPEED : 9600 BPS 
PARITY : NONE 
STOP BITS : 1 
THE PRINT DEVICE IS SET TO THE PRINTER PORT 
I-SET 
6-CUJIT 2-SHOW 
7- 3-COPY 
8-RE-START 4-MONITOR 
g-STOP 5- 
O- 
Password Change 
4.06 It is recommended, for system security, that passwords be 
changed regularly once the SX-200@ DIGITAL PABX has been...