Mitel SX-200 DIGITAL Pabx Engineering Information Manual
Here you can view all the pages of manual Mitel SX-200 DIGITAL Pabx Engineering Information Manual. The Mitel manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 201
Troubleshooting APPENDIX C TWOUBLE§H0081NG KllT Cl.01 l l m 0 l l l l l l m The following is a recommended list of items required in the Field Service Engineering Troubleshooting Kit: One of each circuit card as a spare, including modules Butt set Digital multimeter Moving coil multimeter Static strap Ground mat Assorted screwdrivers, wrenches Long nose pliers Spare fuses Wire strippers Fan filter. Page C-lL1
Page 202
Troubleshooting APPENDIX D LOOP CURRENT MEASUREMENT D1.O1 There are two methods available to measure loop current: 0 In-Line method. 0 Voltage conversion measurement. If it is not possible to break the loop (i.e., open the Tip or Ring lead) the second method may be used: however, it is not as accurate. D1.02 In-Line Method. The procedure for the in-line method of measuring loop current is shown in Figure Dl-1 and is de- scribed as follows: I. Open either the Tip or Ring lead of the trunk...
Page 203
Troubleshooting MDF BRIDGE CLIP TRUNK FACILITY 5512ROEI Figure Dl-1 In-Line Current Measurement Page D-2
Page 204
Troubleshooting 6. The following is a simple calculation used to obtain the loop current value: Loop Current = measured Tip to Ring voltage 250 Page D-3/3
Page 205
Troubleshooting APPENDIX E LOOP START VS GROUND START CHECK El.01 1. 2. 3. 4. 5. 6. 7. The loop start vs ground start check should be performed as follows (also refer to Figure El-l): Locate the PBX trunk circuit Tip and Ring on the connecting block at the MDF. Remove the bridge clips on the Tip and Ring (i.e., disconnect the PBX trunk circuit from the Central Office Tip and Ring). Connect the butt set across the Central Office Tip and Ring. Go off-hook with the butt set. If Central...
Page 206
Troubleshooting CONNECTING BLOCK TO PABX TRUNK CIRCUIT 00 TO CENTRAL OFFICE 00 HOOK SWITCH Figure El-l Loop Start Versus Ground Start Check Page E-2/2
Page 207
Troubleshooting APPENDIIX F IWTEL REPAIR TAG General F1.01 Any card or any other device found faulty must be returned with a Mite1 Repair Tag (see Figure Fl-1). The following in- formation must be included on the repair tag: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. The date on which the device was returned. The location of the point of origin (the installation site). The company name. The product name (i.e., SX-200@ DIGITAL). The system serial number (located on the front of the...
Page 208
Troubleshooting For Customer Use 1. Date: 2. Location: 3. company: 4. Product Name: 5. System Serial No.: 6. Software ID Generic: Revision: 7. Assembly No.: 8. Assembly Serial No.: 9. Alarm/Error Displays: 11. Failure Occurred A) During Installation 8) In Service Further Details issue 3 CAUTION: PLEASE ENSURE PCB ASSEMBLY IS RETURNED IN ANTISTATIC BAG. M0013RO Figure Fl-1 The Mite1 Repair Tag Page F-2/2
Page 209
Troubleshooting ABPENQIX 6 CALL PROCESSING INFORMATION G1.O1 1. 2. 3. 4. 5. 8. 7. 8. 9. 10. 11. 12. 13. 94. 15. 18. 17. - Digital Bay to Digital Bay Call The Main Control Card (MCC) scans for on-hook/off-hook change of state. An extension goes off-hook in Bay 1. The MCC detects the off-hook during its line card scan. MCC checks for the COS of the extension to determine if the call is allowed. The MCC checks for an idle receiver. The MCC connects the DTMF receiver to the line...
Page 210
Troubleshooting 18. 19. 20. 21. 22. G1 .I92 1. 2. 3. 4. 5. 6. 7. 8. 9. IO. 11. 12. 93. 14. 15. Ringing is removed from the destination. Ringback is removed from the originator. A channel is connected between the originator and the destina- tion. The MCC scans for on-hook/off-hook changes of state. When an on-hook is detected, the MCC removes the channel, and the call is terminated. - Analog Bay (Rotary) to Analog Bay Call The Scanner card scans the line circuits for...