Page 161
Troubleshooting - itep 10 11 Action A problem with the DX module on the Main Control card, or with Main Control card itself could cause these symptoms. Replace Main Control card. Description / Follow-up l If problem persists, contact MITEL Field Service. Check if Bay Control card ALARM LED is flashing. Yes 8 Go to step 12. No: l Go to step 15. STEP 12 SHOULD BE DONE DURING PERIODS OF LOW OR NO TRAFFIC, AS IT MAY HAVE AN ADVERSE EFFECT ON SYSTEM PERFORMANCE. DO NOT PROCEED TO STEP 12 UNLESS...
Page 162
Troubleshooting TABLE 4-l BAY CONTROL CARD STATUS LEDs TX LED RX LED on on ALARM LED on Meaning Bay Control card is either waiting for, or has lost communication with the Main Control card. If this state persists for more than a few seconds, there is no communication. flashing flashing on Bay Control card is being downloaded by the Main Control card. flashing flashing Off Bay Control card is up and running and communicating to the Main Control card. Off Off Off .flashing This is the...
Page 163
Troubleshooting I 1 EEI I I K40129RlEl Figure 4-I Bay Control Card Device Locations Page 4-6
Page 164
Troubleshooting ANALOG BAY PERiPHERAL CONTROL’ SUBSYSTEM 4.11 The following paragraphs detail the troubleshooting procedures for the Analog Bay Peripheral Control Subsystem. Configuration 4.12 The Analog Bay Peripheral Control Subsystem consists of the following cards: Name Part No. l Peripheral Control Card (PCC) 9 108-203-OOO-NA 0 PCC EPROM * Digital Interface Card (DIC) 9 108-002-OOO-NA 0 DIC EPROM l Scanner Card 9 11 O-l 04-OOO-NA, 9 11 O-004-OOO-NA Peripheral Control Subsystem Power-Up...
Page 165
Troubleshooting CHART 4-2 ANALOG PERIPHERAL BAY TROUBLESHOOTiNG PROCEDURES tw Action Description / Follow-up Remarks 1 If Scanner 7-segment displays do not read “b3” or l Go to step 2. “b4”, press MASTER RESET pushbutton on the Scanner card front panel. 2 Check if power-up tests have begun. Yes: l Go to step 7. see Note No : * Go to step 3. 1 3 Ensure bay power is turned on. * TOP SHELF POWER switch on the maintenance panel should be in the ON position. * Go to step 4. 4 Verify that power is...
Page 166
CHART 4-2 (Cont’d) ANALOG PERIPHERAL BAY TROUBLESHOOTING PROCEDURES tw Action Description / Follow-up Remarks 12 Replace the Peripheral Control card; power up the Yes: l Power down shelf; go to step 13. bay. Does fault persist? No : l Problem fixed. 13 Replace the Scanner card; power up the bay. Does Yes: * Possible problem with Main Control card; the fault persist? go to step 14. No : l Problem fixed. 14 Power down the system; replace the Main Control Yes: * Refer problem to Mite1 field service....
Page 167
Troubleshooting Notes to Chart 4-2: 1. 2. 3. 4. The correct 7-segment display reset sequence is: 00, bb, OA, b3 (or b4). Refer to Section MITL9108-093-353-NA, General Maintenance Information for details on the Scanner card LED codes. At this point, if there is no call processing in the affected bay, contact Mite1 Field Service. In the peripheral cabinet, the affected DIC card will have the “Rx” LED on (i.e., not off, not flashing) and the “TX” LED off. Refer to Section MITL9108-093-200-NA,...
Page 168
Troubleshookg FLOPPY DISK SUBSYSTEM 4.16 The following paragraphs detail the troubleshooting procedures for the Floppy Disk Subsystem. Chart 4-3 outlines the trouble- shooting procedures for the Floppy Disk Subsystem. Note that some troubleshooting of the Floppy Disk Subsystem is done implicitly through the troubleshooting of the Main Control card. Configuration 4.17 The Floppy Disk Subsystem consists of the following compo- nents: Name Part. No. l Floppy Disk Drive 9 109-024-OOO-NA,...
Page 169
Troubleshooting CHART 4-3 FLOPPY DISK SUBSYSTEM TROUBiESHOOTlNG PROCEDURES ep Action Description / Follow-up Remarks I Ensure bay power is turned on. . Bay power supply switch should be in the ON position. l Go to step 2. ! Verify that power is available in the bay. (Measure Yes: l Go to step 3. see Fig at backplane.) No : . This indicates a power supply problem. 2-2 Refer to the Bay Power Supply troubleshooting procedures. 3 Verify power cable and signal ribbon cable are * Go to step 4. see...
Page 170
Troubleshooting CHART 4-3 (Cont’d) FLOPPY DISK SUBSYSTEM TROUBLESHOOTING PROCEDURES jtep Action Description / Follow-up Remarks 10 Check if Main Control card 7-segment displays Yes: l indicates that the disk drive is empty; go show the following error code: to step Il., E. No: iGotostep12. 4 11 Either (a) Re-insert original diskette, or * NOTE : ONLY RESTART THE SYSTEM (b) insert new diskette and restart the system DURING LOW OR NO TRAFFIC CONDITIONS, AS THIS HAS AN ADVERSE EFFECT ON SYSTEM...