    							SECTION MITL9105/911 O-096-227-NA 
    5. INSTALLATION, PROGRAMMING, AND TESTING OF MODEM LINES 
    General 
    5.01 This Part is concerned with configuring the SX-100’ or 
    SX-200@ PABX when equipped with Associated Modem Line 
    Feature to take advantage of the data features. For PABX installation 
    and programming information, refer to the Installation and Program- 
    ming sections, MITLS 105/9 11 O-096-200-NA and 
    MITL9105/91 lo-096-210-NA. 
    SUPERSET qTM Equipment Port/Modem Line Association 
    5.02 In Associated Modem Line Feature, a SUPERSET@ port is as- 
    sociated with a modem line. Data ports are standard tip and 
    ring connections on standard line circuits. Tables 5-l through 5-3 
    show the steps for installing and programming Associated Modem 
    Line Feature. 
    Step 
    1 
    2 
    3 TABLE 5-l 
    INSTALL CONTROL HARDWARE 
    Action 
    Prepare for new IPC card (91 lo-203-227-NA): 
    IF AND Existing Customer THEN: 
    Installing: Database is to be: 
    A New System N/A Go to Table 5-2 
    Re-designed Go to Step 2 
    A System Saved on Paper via Perform Customer 
    Upgrade Customer Data Print Data Print 
    Saved on Tape via Perform Customer 
    Customer Data Dump Data Dump 
    Turn Control Shelf power OFF. 
    Replace IPC card with new IPC card (part number 9110-203-227-NA) in Shelf 1, 
    Slot 20. 
    4 Turn Control Shelf power ON. 
    Page 27  
    						
    							SECTION MITL9105/91 lo-096-227-NA 
    TABLE 5-2 
    PROGRAM CUSTOMER DATABASE 
    Step Directions 
    1 
    Program system customer database per standard procedures: 
    Saved via Customer 
    2 Enable COS option 126, for each Class-Of-Service to be assigned to: 
    - SUPERSET qTM circuits with an associated data port; 
    - Station circuits used for modem lines. 
    3 Prepare to program SUPERSET qTM circuits which have associated modem lines. 
    l Clear SUPERSET” programming by initializing data block 2 (refer to Vol- 
    ume 3, PN 91 lo-090-003-NA). 
    l Equipment numbers for SUPERSET qTM circuits with associated modem 
    lines must be in the range 009 - 256. 
    4 Access SUPERSET 41M Extended Programming Mode. 
    l Refer to Figure 5-l for SUPERSET 4 TM Extended Programming Overlay. 
    l Press SET EQPT NUMBER, then enter the SUPERSET qTM set equipment 
    number. 
    l Press PRIME KEY. 
    l Press MODEM EQPT NUMBER, then enter the equipment number of the 
    Associated Modem Line, or press DELETE (as required). Press ENTER. 
    l Complete SUPERSET qTM programming (refer to Section MITL9l05/9110- 
    096-2 1 0-NA). 
    5 If more SUPERSET qTM sets are to be programmed, repeat Step 4. 
    l Assigned COS must have COS option 126 (ASSOCIATED DATA PORT) 
    enabled. 
    6 Program a station line circuit for each modem line. 
    l Valid MODEM LINE equipment numbers are in the range of 002-256. 
    l Assigned COS must have COS option 126 (ASSOCIATED DATA PORT) 
    enabled. 
    Page 28  
    						
    							SECTION MITL9105/911 O-096-227-NA 
    LAMP SUPER 
    TEST SET CANCEL 
    KAO114ROEO  SET PRIME SET TRUNK MODEM NEW SET REVIEW ADD ENTER 
    EQPT KEV KEY EQPT EQPT EQPT 
    NUMBER NUMBER NUMBER NUMBER NUMBER 
    , 1 TVPE LISTED cos 
    TOLL BUSV PICKUP ANN. CONFIRM DELETE NEXT 
    NUMBER NUMBER DENY LAMP GROUP EQPT 
    NUMBER 
    Figure 5-l SUPERSET qTM Set Extended Programming Overlay 
    Page 29  
    						
    							SECTION MITL9105/911 O-096-227-NA 
    FRM0133RO 
    Figure 5-2 SUPERSET qTM Set Programming Form 
    Page 30  
    						
    							SECTION MITL9105/911 O-096-227-NA 
    TABLE 5-3 
    Step 
    1 INSTALL STATION HARDWARE 
    Directions 
    Verify that each Station Line circuit used for a MODEM LINE has a valid 
    equipment number, and install a Line Circuit card as required. 
    2 Connect Station Jacks for Modem Lines to assigned Station Line Circuits using 1 
    pair of connection wires. 
    Wiring Considerations 
    5.03 Each modem line associated with a SUPERSET 4TM set requires 
    an additional modular jack and wiring running from the jack to 
    the PABX data port, not physically tied to the SUPERSET qTM set station 
    in any way. 
    Programming Considerations 
    5.04 The PABX must be programmed to enable Generic 217 data 
    capabilities and features (Associated Modem Line Feature). 
    Table 5-4 lists the relevant programming options to be enabled in 
    Associated Modem Line Feature. Options are enabled by setting the 
    appropriate field to the necessary value. Refer to the Programming 
    section, MITL9105191 lo-096-210-NA, for details regarding system 
    programming. 
    5.05 Data ports are associated with SUPERSET qTM sets during 
    SUPERSET@ set programming. Access SUPERSET@ set Extended 
    Programming mode, and follow the steps outlined in Table 5-2. Ensure 
    that each modem line is also assigned a station number, and that the 
    COS of the modem lines has Option 126 enabled. 
    5.06 A- SUPERSET qTM set not associated with a modem line can be 
    programmed to have a modem line as a key line appearance. 
    This permits several SUPERSET qTM set users to have line appearances 
    of various modem lines, and is useful in situations where one data 
    device is to be shared among several data users, as in “printer pool- 
    ing”. 
    5.07 Modem Lines and SUPERSET qTM sets may be placed in Hunt 
    Groups, but SUPERSET qTM sets and their Associated Modem 
    Lines should not be in the same Hunt Groups. Hunt Groups may be 
    used with data devices such as printers. Several printers can be placed 
    in a single Hunt Group. When a PC attempts to place a call to the Hunt 
    Group, the first free printer will be connected to the PC. 
    Page 31  
    						
    							SECTION MITL9105/911 O-096-227-NA 
    LINE CARD 
    CROSS-CONNECT 
    FIELD 
    TEST STATION 
    Figure 5-3 Test Equipment Setup 
    5.08 One modem line may be shared by several SUPERSET qTM sets. 
    During SUPERSET@ set programming, the same data port equip- 
    ment number is entered against each SUPERSET qTM programmed. 
    Testing 
    5.09 The following tests verify that the PABX data features operate 
    correctly. For these tests, an industry-standard telephone is 
    connected to the modem line. The PC and modem are not connected. 
    5.10 Ensure the PABX is operating under Generic 217. Ensure that 
    Customer Data programming -has been completed, and that the 
    Class-of-Service of the SUPERSET qTM set and modem line has COS 
    Option 126 enabled. 
    5.11 
    Connect a test extension (standard telephone) to the station 
    jack of the MODEM LINE to be tested, as shown in Figure 5-3. 
    5.12 Use Tables 5-5 through 5-g to test MODEM LINE operation. 
    Place voice and data calls to ensure the features operate cor- 
    rectly. If the SUPERSET qTM set or test set does not respond correctly, 
    refer to Part 6 of this Practice. 
    Page 32  
    						
    							SECTION MITL9105/911 O-096-227-NA 
    TABLE 5-4 
    ASSOCIATED MODEM LINE FEATURE PROGRAMMING OPTIONS 
    1 PABX 1 OPTION NAME AND TYPE 1 STATUS 
    1 OPTION NUMBER 
    SX-100 ASSOCIATED MODEM LINE 
    sx-200 
    (COS OPTION) 
    TRUNK GROUP ACCESS 
    (COS OPTIONS) ENABLE 
    OPTION NUMBER 126 
    AS REQUIRED OPTIONS 65 - 76 
    SEE NOTE 1 
    1, 2 
    3 
    NOTES: 1. (a) If the Class-of-Service of the modem line is different from that of the associated 
    SUPERSET qTM set, this option must be set for both Classes-of-Service. 
    (b) This option conflicts with COS Option 41 (“Data Security”), and COS Option 101 
    (“Earth Ground Button”). 
    (c) Enabling this option gives the associated modem line data security automatically; 
    the SUPERSET qTM set will NOT have data security. 
    2. (a) SX-lOO@/SX-200@ COS Option 126 disables Option 99 (“Handsfree Station”) in some 
    cases. 
    (b) COS Option 126 sets COS Option 46 (“Flash Disable“) for all stations. 
    (c) If COS Option 126 and COS Option 40 (“Executive Busy Override”) are enabled, 
    modems can override SUPERSET qTM sets; SUPERSET qTM sets can override SUPERSET 
    4TM sets; but modems cannot be overridden. 
    (d) A Modem Line should not be programmed into the same Hunt Group as its 
    associated SUPERSET qTM set. 
    3. If COS Option 127 (“DISA At Night”) is enabled, the selected Trunk will be considered a 
    DISA Trunk while in Night Service only. During Day Service, the Trunk will operate 
    normally. 
    Page 33  
    						
    							SECTION MITLQl OWQl 1 O-096-227-NA 
    Step 
    1 
    2 
    3 
    4 
    5 
    6 
    TABLE 5-5 
    TEST ALTERNATING VOICE AND DATA CALL 
    Action 
    Place a call from the SUPERSET qTM set 
    associated with the MODEM LINE to a trunk 
    or extension number. 
    Press “SWAP” softkey to transfer the call to 
    the MODEM LINE. 
    Press ‘SWAP” softkey to transfer the call to 
    the SUPERSET qTM SET. 
    Press “SWAP” softkey to transfer the call to 
    the MODEM LINE. 
    Set the MODEM LINE extension on-hook. 
    Press the SUPERSET 4’” 
    set HANG-UP 
    softkey. 
    Verification 
    “SWAP” softkey is displayed on SUPERSET 
    qTM set LCD display. 
    NOTE: SWAP appears 
    during an internal call once the called 
    extension answers. 
    Call is transferred to MODEM LINE station. 
    “DATA TRANSFER” is displayed on 
    SUPERSET qTM set LCD display. 
    Call is transferred to SUPERSET qTM set. 
    “SWAP” softkey is displayed on SUPERSET 
    qTM set LCD display. 
    Call is transferred to DATA PORT station. 
    “DATA TRANSFER” is displayed on 
    SUPERSET qTM set LCD display. 
    Call is transferred to the SUPERSET qTM set. 
    “SWAP” softkey is displayed on SUPERSET 
    qTM set LCD display. 
    SLJPERSET qTM set and MODEM LINE station 
    idle. 
    Test completed. 
    Page 34  
    						
    							1. SECTION MITL9105/911 O-096-227-NA 
    Step 
    Step 
    1 
    r 
    2 
    I 
    I 
    , 
    I 
    I 
    A 
    TABLE 5-6 
    TEST SIMULTANEOUS VOICE AND DATA CALLS 
    Action 
    Place a call FROM the SUPERSET qTM set 
    associated with the MODEM LINE TO a trunl 
    or extension number. 
    Press the SUPERSET qTM set SWAP softkey. 
    Press ‘HANG-UP’ softkey on the SUPERSET 
    4TM set. 
    Place a call from the SUPERSET qTM set to 
    a third extension. 
    Hang up the SUPERSET qTM set. 
    Place the MODEM LINE extension on-hook. 
    Verification 
    “SWAP” softkey is displayed on SUPERSET 
    qTM set LCD display. 
    NOTE: SWAP appears 
    during an internal call once the called 
    extension answers. 
    “DATA TRANSFER” is displayed on 
    SUPERSET qTM set LCD display. 
    SUPERSET qTM set LCD display returns to 
    idle display. 
    Voice connection established. 
    SUPERSET qTM set idle. 
    MODEM LINE extension idle. 
    Test completed. 
    TABLE 5-7 
    TEST DATA CALL FROM MODEM LINE 
    Action Verification 
    Place a call FROM the MODEM LINE 
    extension to a second extension; follow the 
    dialed number with a #. Connection established. SUPERSET qTM set 
    remains idle. 
    Place the MODEM LINE extension on-hook MODEM LINE extension idle. 
    Test completed. 
    Page 35  
    						
    							SECTION MITL9105/911 O-096-227-NA 
    TABLE 5-8 
    TEST VOICE CALL FROM MODEM LINE 
    Step Action Verification 
    1 
    Place a call FROM the MODEM LINE Destination is dialed. The call is transferred 
    extension to a trunk or extension; follow to the SUPERSET qTM set. The SUPERSET 
    the dialed number with a %. qTM set is placed in HANDSFREE mode. 
    MODEM LINE extension is locked out. 
    2 Place the MODEM LINE extension on-hook. SUPERSET qTM set is connected to the 
    trunk or extension. 
    3 Hang up the SUPERSET qTM set. SUPERSET qTM set is idle. 
    Test completed. 
    TABLE 5-9 
    TEST DATA CALL TO MODEM LINE 
    Step Action Verification 
    1 
    Place a call TO the MODEM LINE extension MODEM LINE extension rings. 
    from a second extension. 
    2 Answer call at MODEM LINE extension. Connection established. 
    3 Place the second extension on-hook. MODEM LINE extension locked out. 
    4 Place the MODEM LINE extension on-hook. Test completed. 