Miele G 7881 Service Manual
Have a look at the manual Miele G 7881 Service Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 171 Miele manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
3 Fault Repair 3.1 No Water Intake Symptom Water intake only starts after rotation of the circulation pump has been registered; see 050 2.4 Circulation Pump M6. Cause Circulation pump is not running. Remedy ACheck the circulation pump for power or mechanical failure. ASpeed Sensor B3/9 Check, 050 4.1. Cause WaterProof System (WPS) valve does not open. Remedy ASee fault codeF 0Ein 070 2.11.2 Intake/Drain Fault LED and/or 070 Table 51. 3.2 Minimum/Maximum Number of Flow Meter Pulses Not Achieved Cause Flow meter clogged by limescale. Remedy AFlow Meter (Cold Supply Water) Replacement, 041 4.3. x Note The flow meter is behind temperature limiter F2. Cause Reed switch defective. Descriptive Technical Documentation 041-14 DTD no. 62-7881 This information should not be duplicated or passed on without Miele approval. All rights reserved. 18.09.2013, US_am
Remedy ACheck the reed switch for correct operation and seating. ACheck the reed switch connections and plugs. AIf necessary, replace the reed switch; see Reed Switch (Supply Water Flow Meter) Replacement, 041 4.2. Descriptive Technical Documentation DTD no. 62-7881 041-15 18.09.2013, US_am This information should not be duplicated or passed on without Miele approval. All rights reserved.
4 Service 4.1 Reed Switch B8/2 (Salt Container Float Switch) Replacement AService Panel Removal, 022 4.2. ADisconnect the plug connection from the reed switch. AUse needlenose pliers to remove the circuit board (PCB) with reed switch from the salt container. ASlide the PCB with the new reed switch into the holder until it clips into position. AReconnect the plug connection. 4.2 Reed Switch (Supply Water Flow Meter) Replacement AService Panel Removal, 022 4.2. x Note The flow meter is behind temperature limiter F2. ADisconnect the plug connection from the reed switch. AUse needlenose pliers to remove the circuit board (PCB) with reed switch from the flow meter. ASlide the PCB with the new reed switch into the holder until it clips in position. AReconnect the plug connection. Descriptive Technical Documentation 041-16 DTD no. 62-7881 This information should not be duplicated or passed on without Miele approval. All rights reserved. 18.09.2013, US_am
4.3 Flow Meter (Cold Supply Water) Replacement AService Panel Removal, 022 4.2. ARemove the screws securing temperature limiter F2 (030 Fig. 3, Pos. 2). ACarefully lift the temperature limiter slightly. ASlide the flow meter up and out of its holder on the water softener. ADisconnect the plug connection from the reed switch and disconnect the hoses. AInstall the new flow meter by following these instructions in reverse order. 4.4 Water Diverter Removal ARemove the right-hand side panel (Side Panel Removal, 010 4.1). AUnclamp all hoses from the diverter. AUnclip the diverter from the inside of the cabinet and from the mounting bracket on the outside of the machine. Descriptive Technical Documentation DTD no. 62-7881 041-17 18.09.2013, US_am This information should not be duplicated or passed on without Miele approval. All rights reserved.
042 Demineralized-Water Intake x Descriptive Technical Documentation DTD no. 62-7881 042-1 18.09.2013, US_am This information should not be duplicated or passed on without Miele approval. All rights reserved.
1 Technical Data Solenoid Data Valve VoltageFlow PressureFlow RateConnection Length 1)Threaded Union Demineraliz- ed water (Y20)1N AC 220/240 V 50/60 Hz21.8 - 145 psi (1.5 - 10 bar) 2) 2.1 gal/min (7.5 L/min)5.6' (1.7 m) 3/4" Table 1:WaterProof System Data (as per Parts CD) 1)The standard WaterProof system hose can be replaced with a 14.8-foot (4.5-meter) version.2)With a pressure of 7.3 to 21.8 pounds per square inch (0.5 to 1.5 bar), the water intake time is automatically extended by up to 5 minutes. x Drain Pump - Demineralized Water Type VoltagePower RatingMax. Head HeightMax. Flow RateWinding Protection BE24B4–0871N AC 230/240 V 50 HzApprox. 85VA3.3' (1m)2.6 gal/min (10L/min)Integrated Table 2:Drain Pump, Installed in Demineralized Water Intake Descriptive Technical Documentation 042-2 DTD no. 62-7881 This information should not be duplicated or passed on without Miele approval. All rights reserved. 18.09.2013, US_am
050 Drainage, Sump, Circulation Pump Descriptive Technical Documentation DTD no. 62-7881 050-1 18.09.2013, US_am This information should not be duplicated or passed on without Miele approval. All rights reserved.
1 Technical Data Type VoltagePower RatingMax. Flow PressureMax. Flow RateWinding Protection Drain pumpBE28B31N AC 200/ 220 V 60HzApprox. 80 VA—min. 4.2 gal/min (16 L/min)Integrated Circulation pumpMPE 11– 64/21N AC 220V 60HzApprox. 600 VA13 psi (0.9 bar)106 gal/min (400 L/min)Integrated Table 1:Pump Data (as per Parts CD) Descriptive Technical Documentation 050-2 DTD no. 62-7881 This information should not be duplicated or passed on without Miele approval. All rights reserved. 18.09.2013, US_am
2 Function 2.1 Sump and Associated Components x Fig. 1:Sump and Associated Components 1 Float switch holder 2 Drain pump, M8 3 Heater level switch, B1/10 4 Circulation pump, M6 5 Speed sensor, B3/9 6 Water intake level switch, B1/1 7 Float switch housing 8 Float switch, B8/3 9 Float Descriptive Technical Documentation DTD no. 62-7881 050-3 18.09.2013, US_am This information should not be duplicated or passed on without Miele approval. All rights reserved.
2.2 Drainage The machine comes supplied with a 5-foot, flexible drain hose (7⁄8-inch inner diameter). In non-CD models, the steam condenser is drained internally through the existing drain hose. The machine has a removable non-return valve. The drain height should not exceed 3 feet. Floor drains are permissible; additionally, the drain hose may be lengthened to 13 feet. 2.3 Drain Pump M8 Drain pump M8 (050 Fig. 1, Pos. 2) is located below the cabinet and is connected to the right of the sump. It is controlled directly by the electronic (070 Fig. 5, Pos. 17). It pumps out wash water from the lowest point in the sump via a non-return valve and sends the water via the drain hose to the on-site drain. A vent is provided to prevent siphoning. 2.4 Circulation Pump M6 Circulation pump M6 (050 Fig. 1, Pos. 4) takes in the wash water from the side of the sumpthroughthe filter combination (030 2.4 Filter System), and pumps it to the spray arms. Before each water intake, the circulation pump is checked via a start routine. There are up to 3 start attempts (each lasts about 2 to 3 seconds) with different voltages. If the speed sensor still does not register any rotation after the third attempt, the WPS valve is not opened and fault codeF 08(070 Table 51) is displayed. 2.5 Speed Sensor B3/9, Gentle Start of Circulation Pump The circulation pump is equipped with a speed sensor (050 Fig. 1, Pos. 5) that continually monitors the pump speed and sends appropriate signals (8 pulses per revolution) to the electronic. Here these signals are evaluated and the circulation pump speed is adjusted as necessary to achieve the desired speed (reduced/full speed). Pulse measurements at the speed sensor are not expected to be made. An open circuit in one of the sensor connections or a blocked circulation pump will cause fault codeF 08(070 Table 51) to be displayed. Descriptive Technical Documentation 050-4 DTD no. 62-7881 This information should not be duplicated or passed on without Miele approval. All rights reserved. 18.09.2013, US_am