    							4 Service
    4.1 Programming Mode Summary
    Initial requirements
    AClose the door and shut off the machine.
    ATurn the program selector switch to the 12 o'clock setting.
    Accessing
    APress and hold the topmin°Cand bottom6program function buttons
    together.
    ATurn on the machine and release the buttons.
    Acknowledgement indicator
    The display shows the current software index, e.g.,P 00.
    TheIntake/DrainLED lights up.
    If this is not the case, repeat the process.
    An exception is the rinse aidHLED. If this lights up, rinse aid or an external
    disinfectant must be added to the appropriate dispenser.
    Options
    APress the middlecprogram function button as necessary to advance to the
    desired programming level (E 01-E 34).
    For programming level descriptions, see 070 2.8 Programming Mode -
    Programming LevelsE 01toE 34.
    AWhen the desired programming level has been selected, turn the program
    selector switch to the program or function setting that is to be modified in
    accordance with the appropriate table.
    APress the topmin°Cprogram function button as necessary to page through
    the available options.
    ATurn the program selector switch to the 12 o'clock setting to save the selected
    option.
    AIf appropriate, press thecbutton again as necessary to advance to the
    desired programming level and make other modifications as required.
    The previously made modifications remain applicable. If a dash—is shown in the
    display, the program position is vacant or the appropriate component is not
    activated, not present or its parameters cannot be modified.
    Descriptive Technical Documentation
    070-56 DTD no. 62-7881
    This information should not be duplicated or passed on without Miele approval. All rights reserved. 18.09.2013, US_am 
    						
    							x
    Note
    Parameters or functions canonlybe modified via the topmin°Cprogram
    function button. The programming level isonlydisplayed when the program
    selector switch is turned to the 12 o'clock setting. If thecbutton is pressed, the
    electronic advances immediately to the next programming levelwithoutthe
    appropriate display.
    Save and quit
    APress the6button twice.
    AShut off the machine.
    x
    Note
    Each individual setting modification does not have to be saved separately. After
    all desired modifications have been made, they can be saved together.
    4.2 Service Mode 1 Summary
    Initial requirements
    AClose the door and shut off the machine.
    ATurn the program selector switch to the 12 o'clock setting.
    Accessing
    APress and hold themin°Candcbuttons together.
    ATurn on the machine and release the buttons.
    Acknowledgement indicator
    The digital display shows the current statusS10for service mode 1.
    TheIntake/DrainLED lights up.
    If this is not the case, repeat the accessing process.
    An exception is the rinse aidHLED. If this lights up, rinse aid or an external
    disinfectant must be added to the appropriate dispenser.
    Descriptive Technical Documentation
    DTD no. 62-7881 070-57
    18.09.2013, US_am This information should not be duplicated or passed on without Miele approval. All rights reserved. 
    						
    							Options
    x
    ProgramProgram Selector
    Switch SettingProgram Function
    ButtonDigital Display
    Switching step
    checkSelect a program—First wash temperature
    —Press6to advance
    switching stepSwitching step
    Test program 8 o'clockPress6to start program First wash temperature
    Table 52:Service Mode 1 Summary
    Quit (without saving)
    ATurn the program selector switch to the 12 o'clock setting.
    AShut off the machine.
    4.3 Service Mode 2 Summary
    Initial requirements
    AClose the door and shut off the machine.
    ATurn the program selector switch to the 12 o'clock setting.
    Accessing
    APress and hold the6andcbuttons together.
    x
    Note
    If the programming mode is blocked, access to service mode 2 is made more
    difficult. In this case both program function buttons must be pressed and held
    together for approximately 2 seconds.
    ATurn on the machine and release the buttons.
    Acknowledgement indicator
    The display shows the current software index, e.g.,P 00.
    TheIntake/DrainLED lights up.
    If this is not the case, repeat the accessing process.
    An exception is the rinse aidHLED. If this lights up, rinse aid or an external
    disinfectant must be added to the appropriate dispenser.
    Descriptive Technical Documentation
    070-58 DTD no. 62-7881
    This information should not be duplicated or passed on without Miele approval. All rights reserved. 18.09.2013, US_am 
    						
    							Options
    APress thecbutton as necessary to advance to the desired service level (S
    21-S 27).
    For service mode 2 details, see 070 2.9 Service Mode 2 - Service LevelsS 21to
    S 27.
    ATurn the program selector switch to the desired function setting.
    APress themin°Cbutton as necessary to page through the available options.
    ATurn the program selector switch to the 12 o'clock setting to save the selected
    option.
    AIf required, press thecbutton again as necessary to advance to the desired
    programming level and make other modifications as desired.
    The previously made modifications remain applicable. If a dash—is shown in the
    digital display, the program position is vacant or the appropriate component is not
    activated, not present or its parameters cannot be modified.
    x
    Note
    Parameters or functions canonlybe modified via themin°Cbutton. The
    programming level isonlydisplayed when the program selector switch is turned
    to the 12 o'clock setting. Ifcis pressed, the electronic advances immediately
    to the next programming levelwithoutthe appropriate display.
    Save and quit
    APress the6button twice.
    AShut off the machine.
    x
    Note
    Each individual setting modification does not have to be saved separately. After
    all desired modifications have been made, they can be saved together.
    Descriptive Technical Documentation
    DTD no. 62-7881 070-59
    18.09.2013, US_am This information should not be duplicated or passed on without Miele approval. All rights reserved. 
    						
    							4.4 Electronic Module EPGL 081 Removal
    APull off the switch knob. See 070 Fig. 14, Pos. 4.
    ARemove the 6 screws securing the fascia panel to the door inner panel (4
    across the top and 1 on each side).
    ARemove the fascia panel with electronic.
    ARemove the 6 screws securing the mounting bracket to the fascia panel.
    Remove the mounting bracket from the fascia panel. See 070 Fig. 14, Pos. 2.
    ARemove the 5 screws securing the electronic to the mounting bracket; see
    070 Fig. 14, Pos. 1. Remove the electronic from the mounting bracket.
    ADisconnect the plug connections (coded) from the electronic.
    x
    Fig. 14:EGPL 081 with Retaining Bracket
    Note
    When re-installing, ensure that the selector disk of the program selector switch
    correctly engages with the coupling disk on the electronic.
    Descriptive Technical Documentation
    070-60 DTD no. 62-7881
    This information should not be duplicated or passed on without Miele approval. All rights reserved. 18.09.2013, US_am 
    						
    							4.5 Electronic Module EZL 081 Removal
    AService Panel Removal, 022 4.2.
    AToekick Removal, 010 4.6.
    ARemove the 2 top screws securing the electronic. See 070 Fig. 15. Remove
    the electronic.
    ASlightly bend the retaining clips outward and remove the circuit board. See
    070 Fig. 15, Pos. 1.
    x
    Fig. 15:EZL 081 Removal
    4.6 Fuse Removal
    APull off the switch knob.
    ARemove the 6 screws securing the fascia panel to the door inner panel (4
    across the top and 1 on each side).
    AUnscrew the fuse cap and pull out the fuse.
    Descriptive Technical Documentation
    DTD no. 62-7881 070-61
    18.09.2013, US_am This information should not be duplicated or passed on without Miele approval. All rights reserved. 
    						
    							072 Fascia Panel, Electronic
    G 7882 CD, G 7883 CD
    2 Function
    2.1 Program Summaries
    2.1.1 Program Summary (P 06) - G 7882 CD
    x
    Program Block G 7882 CD Wash Programs1)
    SPECIAL 93°C-10 minSPECIAL AN 93°C-10
    minvario TD vario TD AN
    VR 1[—] [—][10 L cold water]
    — [1 min]
    [60 s drainage]
    VR 2[—] [—]—[15.5 L cold water]
    [1 min]
    [90 s drainage]
    HR 1[10.5 L cold water] [16 L cold water]10.5 L cold water 16 L cold water
    [DOS 1 / 40°C] [DOS 1 / 40°C]DOS 1 / 40°C DOS 1 / 40°C
    [[93°C / 10 min]] [[93°C / 10 min]]55°C / 5 min 55°C / 5 min
    [60 s drainage] [90 s drainage] 60 s drainage 90 s drainage
    HR 2[—] [—]— —
    CH-DESIN[—] [—] [—] [—]
    SP 1— — — —
    SP 2[9 L cold water] [14.5 L cold water]9 L cold water 14.5 L cold water
    [DOS 3 immediately] [DOS 3 immediately]DOS 3 immediately DOS 3 immediately
    [1 min] [1 min]1 min 1 min
    [60 s drainage] [90 s drainage]60 s drainage 90 s drainage
    SP 35 L cold water
    —5 L cold water 10.5 L cold water
    1 min 1 min 1 min
    60 s drainage 60 s drainage 90 s drainage
    SP 4— — — —
    NS 1[—] [—]— —
    NS 2[9.5 L demineralized
    water][15 L demineralized
    water]9.5 L demineralized
    water15 L demineralized
    water
    [75°C / 3 min] [75°C / 3 min]93°C / 5 min 83°C / 10 min
    [60 s drainage] [90 s drainage]60 s drainage 90 s drainage
    TA 1—99°C / 10 min—99°C / 10 min
    TA1 / TA2 99°C / 35 min 90°C / 35 min 99°C / 35 min 90°C / 35 min
    Table 1:Program Summary G 7882 CD (P 06), Part 1
    1)The program blocks that appear in bold within the square brackets are fixed and cannot be activated or deactivated,
    except for the type of water intake. This can be changed in a wash block that cannot be deactivated. Individual values in
    “[[ ... ]]”can also not be modified.
    Descriptive Technical Documentation
    DTD no. 62-7881 072-1
    18.09.2013, US_am This information should not be duplicated or passed on without Miele approval. All rights reserved. 
    						
    							x
    Program
    BlockG 7882 CD Wash Programs1)
    CHEM 60°C-5 mincombi CHEM
    60°C-5 minA (frei) vario TD NR UNIVERSAL
    VR 1— — —10 L cold water[10 L cold water]
    1 min[1 min]
    60 s drainage[60 s drainage]
    VR 2[10 L cold water] [10 L cold water]
    — — — [1 min] [1 min]
    [60 s drainage] [60 s drainage]
    HR 1[10.5 L cold water] [10.5 L cold water]
    — —10.5 L cold water
    [DOS 1 / 40°C] [DOS 1 / 40°C]DOS 1 / 40°C
    [60°C / 3 min] [55°C / 3 min]60°C / 3 min
    [60 s drainage] [—]60 s drainage
    HR 2[—] [—]—10.5 L cold water
    — DOS 1 / 40°C
    55°C / 5 min
    60 s drainage
    CH-DESIN[10.5 L cold water] [[—]]
    — —[—] [DOS 4
    immediately][DOS 4
    immediately]
    [60°C / 5 min] [60°C / 5 min]
    [60 s drainage] [60 s drainage]
    SP 1— — — — —
    SP 2— — — — —
    SP 3— — —5 L cold water
    — 1 min
    60 s drainage
    SP 49 L cold water 9 L cold water
    —9 L cold water 9 L cold water
    1 min 1 min 1 min 1 min
    60 s drainage 60 s drainage 60 s drainage 60 s drainage
    NS 1— — — — —
    NS 29.5 L demineralized
    water9.5 L demineralized
    water
    —9.5 L demineralized
    water9.5 L demineralized
    water
    60°C / 3 min 60°C / 3 min 93°C / 5 min 65°C / 1 min
    60 s drainage 60 s drainage 60 s drainage 60 s drainage
    TA 1 80°C / 5 min 80°C / 5 min— —80°C / 5 min
    TA1 / TA2 60°C / 40 min 60°C / 40 min—99°C / 35 min 65°C / 25 min
    Table 2:Program Summary G 7882 CD (P 06), Part 2
    1)The program blocks that appear in bold within the square brackets are fixed and cannot be activated or deactivated,
    except for the type of water intake. This can be changed in a wash block that cannot be deactivated. Individual values in
    “[[ ... ]]”can also not be modified.
    2.1.2 Program Summary (P 06) - G 7883 CD
    x
    Program Block G 7883 CD Wash Programs1)
    SPECIAL 93°C-10 min vario TD Customer Anorganica
    VR 1[—][10 L cold water]10 L cold water
    — [1 min]1 min
    [60 s drainage]60 s drainage
    Descriptive Technical Documentation
    072-2 DTD no. 62-7881
    This information should not be duplicated or passed on without Miele approval. All rights reserved. 18.09.2013, US_am 
    						
    							Program Block G 7883 CD Wash Programs1)
    SPECIAL 93°C-10 min vario TD Customer Anorganica
    VR 2[—]— —10 L cold water
    DOS 3 immediately
    50°C /[[1]]min
    60 s drainage
    HR 1[10.5 L cold water]10.5 L cold water
    — — [DOS 1 / 40°C]DOS 1 / 40°C
    [[93°C / 10 min]]55°C / 5 min
    [60 s drainage]60 s drainage
    HR 2[—]—10.5 L hot water 10.5 L hot water
    DOS 1 / 40°C DOS 1 / 40°C
    80°C / 3 min 75°C / 3 min
    60 s drainage 60 s drainage
    CH-DESIN[—] [—]— —
    SP 1— — — —
    SP 2[9 L hot water]9 L hot water 9 L hot water 9 L hot water
    [DOS 3 immediately]DOS 3 immediately DOS 3 immediately DOS 3 immediately
    [1 min]1 min 1 min 1 min
    [60 s drainage]60 s drainage 60 s drainage 60 s drainage
    SP 35 L hot water 5 L hot water 5 L hot water 5 L demineralized water
    1 min 1 min 1 min 1 min
    60 s drainage 60 s drainage 60 s drainage 60 s drainage
    SP 4— —9 L demineralized water 9 L demineralized water
    1 min 1 min
    60 s drainage 60 s drainage
    NS 1[—]— — —
    NS 2[9.5 L demineralized
    water]9.5 L demineralized
    water9.5 L demineralized
    water9.5 L demineralized
    water
    [75°C / 3 min]93°C / 5 min 75°C / 1 min 70°C / 1 min
    [60 s drainage]60 s drainage 60 s drainage 60 s drainage
    TA 1— —99°C / 25 min 99°C / 25 min
    TA1 / TA2 99°C / 35 min 99°C / 35 min 70°C / 5 min 70°C / 5 min
    Table 3:Program Summary G 7883 CD (P 06), Part 1
    1)The program blocks that appear in bold within the square brackets are fixed and cannot be activated or deactivated,
    except for the type of water intake. This can be changed in a wash block that cannot be deactivated. Individual values in
    “[[ ... ]]”can also not be modified.
    x
    Program
    BlockG 7883 CD Wash Programs1)
    Organica Standard Universal Intensive Plastic
    VR 1— —10 L cold water 10 L cold water 10 L cold water
    1 min 1 min 1 min
    60 s drainage 60 s drainage 60 s drainage
    VR 2— — — — —
    HR 110.5 L hot water
    — — — — DOS 1 / 40°C
    65°C / 3 min
    60 s drainage
    Descriptive Technical Documentation
    DTD no. 62-7881 072-3
    18.09.2013, US_am This information should not be duplicated or passed on without Miele approval. All rights reserved. 
    						
    							Program
    BlockG 7883 CD Wash Programs1)
    Organica Standard Universal Intensive Plastic
    HR 210.5 L hot water[10.5 L hot water] [10.5 L hot water]10.5 L hot water 10.5 L cold water
    DOS 1 / 40°C[DOS 1 / 40°C] [DOS 1 / 40°C]DOS 1 / 40°C DOS 1 / 40°C
    85°C / 3 min[75°C / 3 min] [80°C / 3 min]85°C / 3 min 55°C / 5 min
    60 s drainage[60 s drainage] [60 s drainage]60 s drainage 60 s drainage
    CH-DESIN—[—] [—] [—] [—]
    SP 1— — — — —
    SP 29 L hot water 9 L hot water 9 L hot water 9 L hot water 9 L cold water
    DOS 3 immediately DOS 3 immediately DOS 3 immediately DOS 3 immediately DOS 3 immediately
    1 min 1 min 1 min 1 min 1 min
    60 s drainage 60 s drainage 60 s drainage 60 s drainage 60 s drainage
    SP 35 L hot water
    —5 L hot water
    —5 L cold water
    1 min 1 min 1 min
    60 s drainage 60 s drainage 60 s drainage
    SP 49 L demineralized
    water9 L demineralized
    water9 L demineralized
    water9 L demineralized
    water9 L cold water
    1 min 1 min 1 min 1 min 1 min
    60 s drainage 60 s drainage 60 s drainage 60 s drainage 60 s drainage
    NS 1— — —9.5 L demineralized
    water9.5 L demineralized
    water
    0°C / 1 min 55°C / 1 min
    60 s drainage 60 s drainage
    NS 29.5 L demineralized
    water[9.5 L
    demineralized
    water]9.5 L demineralized
    water9.5 L demineralized
    water
    —
    80°C / 1 min[75°C / 1 min]75°C / 1 min 80°C / 1 min
    60 s drainage[60 s drainage]60 s drainage 60 s drainage
    TA 1 99°C / 25 min 99°C / 25 min 99°C / 25 min 99°C / 25 min 65°C / 5 min
    TA1 / TA2 70°C / 5 min 70°C / 5 min 70°C / 5 min 70°C / 5 min 55°C / 35 min
    Table 4:Program Summary G 7883 CD (P 06), Part 2
    1)The program blocks that appear in bold within the square brackets are fixed and cannot be activated or deactivated,
    except for the type of water intake. This can be changed in a wash block that cannot be deactivated. Individual values in
    “[[ ... ]]”can also not be modified.
    Descriptive Technical Documentation
    072-4 DTD no. 62-7881
    This information should not be duplicated or passed on without Miele approval. All rights reserved. 18.09.2013, US_am 
    						
    All Miele manuals Comments (0)