DENY CODES FOR CLASS OF SERVICE 2 (C) (PROGRAM Description: 35) This.p.rogram defines what leading digits in a dialing plan are to be restricted. There are 10 line entries (O-9) whichdefineupro 12 digits per entry. . Programming: 1. Press [#I. - 2. UProgramming” is displayed. Dial 35. 3. ‘Deny in Class C” is displayed. Enter [0] to [9] to select line entry. ‘CD X” is displayed. 4. Enter digit sequence to be toll restricted. 5. To erase existing digit sequence, press “HOLD” key. 6. Press...
Page 82
ALLOW CODES FOR CLASS OF SERVICE 2 (C) (PROGRAM-36) Description: This program defines what leading digits in a dialing plan are to be aIlowed. There are 10 line entries (O-9) which define up .to 12 digits per.entry. Programming: 1. 2. 3. 4. 5. Press [#I. - “Programmin g” is displayed. Dial 36. “Allow in Class C” is displayed. Enter [0] to [9] to select line entry. “CA xn is displayed. Enter allowed diaIed digits. To erase existing digit sequence press “HOLD” key Press [#I to save and...
Page 83
ALLOW CODES FOR CLASS OF SERVICE 3 (D) - (PROGRAM 37) l -Da&ptioa:. . . This program defmes what leading digits in a dialing plan are-to be allowed. There are 10 line entries (O-9) which define up to 12 digits per entry. Programming: 1. Press [#J ‘Programming” is displayed. 2. Dial 37. “Allow in Class D” is displayed. 3. Enter [0] to [9] to select line entry. “DA x” is displayed. 4. Enter allowed dialed digits. 5. To erase existing digit sequence press ‘HOLD” key. 6. Press [#}....
Page 84
TOLL RESTRICTION OVERRIDE (PROGRAM 01,02,03) Description: Allows-the system programmer to assign specific passwords for each toll class of service. With. these passwords the station users are permitted to place calls on a telephone set that is normally toll restricted. Also referred to a traveling class of service. Programming: 1. Press [#] “Programming” is displayed 2. Press 01 (A), 02 (B) or 03 (C) ‘Class: x: xxxxx” is displayed 3. Enter new password for class of service 4. Press [#I to...
Page 85
TELEPHONE TYPE (PROGRAM 38) Description: Allowsinstaller. to definethe type of telephone assigned to each, port. . _ Programming: 1. Press [#I. ‘Programming” is displayed. 2. Dial 38. “SLT DIAL TYPE” is displayed, then U-” is displayed. 3. Enter [0] for keyphone, “1” for DTMF SLT or “2” for dial pulse SLT 4. Press [#J to save and exit Conditions: l Default value for SLT ports is N l System recognizes keyphone ports automatically l Entry input must be all 16 digits even if only one station...
Page 86
TRUNK NAMES (PROGRAM 39) **** Description: This program is tiedto enter an identification or directory name for each CO line. The assigned trunk in the directory will be displayed during the incoming outside call. Programming: 1. Press[#]. 2. Press [39]. “Line Directory” is displayed. 3. Press the CO line button to be named, for example, CO line 1. “Line 1:” and the current data is displayed. 4. Press the HOLD button to clear the old data. 5. Enter the name by using the method, such as MMC14...
Page 87
ASSIGN PRIVACY (PROGRAM 41) *** Description: This enables-the system-programmer to assign privacy or temove privacy from all CO line. Programming: 1. Press [#j. ‘Programming” is displayed. 2. Dial 41. ‘Privacy Enable” is displayed. 3. Enter password . 4. Enter 0 = Privacy Disable Enter 1 - Privacy Enable 5. Press [x] to save and exit. Conditions: l Default is 0 (Privacy Enabled). 82
Page 88
CO LINE DIAL MODE SELECTION (TONE/PULSE) (PROGRAM 42) Description: This enables the system programmer to define which CO lines are to be classed as either tone dial or dial pulse lines. Programming: 1. Press [#]. “ProgramAn g” is displayed. 2. Dial 42. “Trunk Dial type” is displayed. “XXSXXXX~ is displayed. 0 - Dial pulse lines 1 = DTMF lines 3. Enter Data. 4. Press [#] to save and exit. Default value is 0. This program requires that all digits for that field must be entered regardless if...
Page 89
CO LINE ENABLED FOR SERVICE (PROGRAM 43) Description: This enables the system programmer to define what. lines are to be enabled in the system. Programming: 1. Press [#I. yProgramming” is displayed. 2. Dial 43. “Tnmk Tie” is displayed. 0 = CO line is not connected. 1 - CO line is connected. 3 - E/M Tie line 3. Enter Data. 4. Press [#I to save and exit. conditions: l Default value is 1. l This program requires that all digits for that field must be entered regardless if the data is to be...
Page 90
CO UNE DEFINITION (PROGRAM 44) Description: l This enables the system programmer to define which lines are directly connected to a CO line or to a PABX line. If ali.ne.is classed as a PABX line, no toll restriction will be activated. Programming: 1. Press [#I. “Programming” is displayed. 2. Dial 44. “PO CO TRUNK” is displayed. O-PABXline I-COline 3. Enter 0 or 1. 4. Press [#I to save and exit. conditions: l Default value - U 1111111”. l This program requires that all digits for that...