Home > Lucent Technologies > Communications System > Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Administration For Network Connectivity Manual

Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Administration For Network Connectivity Manual

Here you can view all the pages of manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Administration For Network Connectivity Manual. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 101

Configuration 2: R7r (+CMS)  R7csi 
81
Administration for Network Connectivity
555-233-504— Issue 1 — April 2000 CID: 77730
3  C-LAN Administration
Destination Node Name of the far-end node for this channel. This must be a 
name entered on the Node Names screen. 
Destination Port A value of 0 allows any available interface channel on the 
destination node to be used for this connection. The Interface 
Channel number on the Switch-2 Processor Channel screen 
must also be set to 0.
Session - Local The...

Page 102

Configuration 2: R7r (+CMS)  R7csi 3  C-LAN Administration
Administration for Network Connectivity
CID: 77730 555-233-504 — Issue 1 — April 2000
82
> Submit the screen
End
Session - Local The Local and Remote Session numbers can be any value 
between 1 and 256 (si model) or 384 (r model), but they must 
be consistent between endpoints. For each connection, the 
Local Session number on this switch must equal the Remote 
Session number on the remote switch and vice versa.
It is allowed, and sometimes...

Page 103

Configuration 2: R7r (+CMS)  R7csi 
83
Administration for Network Connectivity
555-233-504— Issue 1 — April 2000 CID: 77730
3  C-LAN Administration
Switch 2 Task — Enable Bus Bridge Connectivity
This task enables the bus bridge functionality on the C-LAN circuit pack to provide a 
path between the packet bus and the processor. 
Note:Bus Bridge Connectivity is used on the csi model only. This task may 
have been completed when the C-LAN circuit pack was installed.
Begin
Steps
> Open the...

Page 104

Configuration 2: R7r (+CMS)  R7csi 3  C-LAN Administration
Administration for Network Connectivity
CID: 77730 555-233-504 — Issue 1 — April 2000
84
Switch 2 Task — Assign Node Names
This task assigns node names and IP addresses to each node in the network on the 
Node Names screen. This screen is administered on Switch 2. A Node Names screen 
must be administered on each switch in the network.
The node names and IP addresses in a network should be assigned in a logical and 
consistent manner from the...

Page 105

Configuration 2: R7r (+CMS)  R7csi 
85
Administration for Network Connectivity
555-233-504— Issue 1 — April 2000 CID: 77730
3  C-LAN Administration
Switch 2 Task — Define IP Interfaces
The IP interface for each C-LAN and MedPro board on the switch must be defined on 
the IP Interfaces form. Each DEFINITY switch in an IP network has one IP Interfaces 
form.
Begin
Steps
> Open IP Interfaces form — enter  ch ip-i
> Enter values
change ip-interfaces  Page   1 of   2 
IP Interfaces
Inter-region IP...

Page 106

Configuration 2: R7r (+CMS)  R7csi 3  C-LAN Administration
Administration for Network Connectivity
CID: 77730 555-233-504 — Issue 1 — April 2000
86
Subnet Mask Enter the subnet mask associated with the IP address for 
this IP interface. (The IP address is associated with the 
node name on the Node Names screen). 
Since the node-1 and node-5 IP interfaces are on the same 
network (192.168.1), they must be assigned the same 
subnet mask.
In this example, the subnet mask 255.255.255.224 divides 
the network...

Page 107

Configuration 2: R7r (+CMS)  R7csi 
87
Administration for Network Connectivity
555-233-504— Issue 1 — April 2000 CID: 77730
3  C-LAN Administration
Switch 2 Task— Assign Link via ethernet Data Module to the LAN
This task administers an ethernet data module on Switch 2 for the ethernet connection 
to Switch 1. The data module associates a link number with a port address, extension 
number, and node name for the C-LAN port used for this connection.
Begin
Steps
> 
Open Data Module form — enter ad da n
[This...

Page 108

Configuration 2: R7r (+CMS)  R7csi 3  C-LAN Administration
Administration for Network Connectivity
CID: 77730 555-233-504 — Issue 1 — April 2000
88
Switch 2 Task — Assign IP Route (to Switch 1)
This task specifies a route for packets sent by the node 5 IP interface (the ethernet port 
on the switch-2 C-LAN board) to the nodes 1 and 2. An IP route is required because 
node 5 is on a different subnetwork from nodes 1&2 (as defined in the Subnet Mask 
field on the IP Interfaces screen), and the Gateway...

Page 109

Configuration 2: R7r (+CMS)  R7csi 
89
Administration for Network Connectivity
555-233-504— Issue 1 — April 2000 CID: 77730
3  C-LAN Administration
Note:We could have defined 2 individual IP routes, one each to node-1 and 
node-2, instead of this IP route. However, the network route is easier 
because we need only one. The network route enables packets to get to 
any IP address on the 192.168.1.96 subnet (that is, addresses 
192.168.1.97 through 192.168.1.126), so no other IP routes are needed.
No IP...

Page 110

Configuration 2: R7r (+CMS)  R7csi 3  C-LAN Administration
Administration for Network Connectivity
CID: 77730 555-233-504 — Issue 1 — April 2000
90
Switch 2 Task— Assign Processor Channels
This task associates data links (hardware) with processor channels (software) on 
Switch 2.
Begin
Steps
> Open the Processor Channel Assignment form — enter  ch com p
> Enter values
change communications-interface processor-channels
                                                                    Page 1 of X...