Page 111
Installing Software and Setting Up CMS CentreVu® CMS R3V8 Software Installation and Setup Installing DiskSuite2-93 10. To create and mount /cms, enter: mkdir /cms mount /cms 11. Enter: eject cdrom Configuring DiskSuite on a mirrored system 2 This procedure configures DiskSuite on a unmirrored Enterprise 3000 or 3500 system. 1. Enter: stty erase (where means “press/hold Control as you press H”) The stty command sets up your backspace key as an actual backspace. If you do not enter this command,...
Page 112
Installing Software and Setting Up CMS CentreVu® CMS R3V8 Software Installation and Setup Installing DiskSuite2-94 8. To reboot, enter: /usr/sbin/shutdown -y -g0 -i0 When the ok prompt is displayed, enter: boot -r When the reboot is finished, log in as root. 9. To setup the /cms metadevices, enter the following commands: export PATH=$PATH:/olds:/usr/opt/SUNWmd/sbin olds -mirrored -setup The system should respond: Success, /cms mirrored successfully 10. Enter the following commands: mkdir /cms mount...
Page 113
Installing Software and Setting Up CMS CentreVu® CMS R3V8 Software Installation and Setup Installing DiskSuite2-95 Checking for Disk Recognition Errors 2 The procedures in the section will help you to diagnose problems with unrecognized disk drives. This procedure is different for the different hardware platforms. Use this procedure only if the DiskSuite scripts indicate there is a disk recognition error. Do NOT do this as part of the normal installation procedure. Disk Recognition Errors on...
Page 114
Installing Software and Setting Up CMS CentreVu® CMS R3V8 Software Installation and Setup Installing DiskSuite2-96 9. To verify that the system sees all IDE devices, enter: probe-ide The program responds similar to the following: 10. To verify that the system sees all SCSI devices, enter: probe-scsi-all The program responds similar to the following: 11. Verify that all of the disk drives are recognized. If the devices are still not recognized, see CentreVu® CMS R3V8 Hardware Maintenance and...
Page 115
Installing Software and Setting Up CMS CentreVu® CMS R3V8 Software Installation and Setup Installing DiskSuite2-97 13. Enter boot -r. The system reboots. 14. Log in as root. 15. Repeat the procedures described in “Configuring DiskSuite on an unmirrored system” on Page 2-88, or “Configuring DiskSuite on a mirrored system” on Page 2-93. Disk Recognition Errors on Enterprise35002 1. Reboot the system with an init 0 command. The system reboots and displays the ok prompt. 2. Turn off the system...
Page 116
Installing Software and Setting Up CMS CentreVu® CMS R3V8 Software Installation and Setup Installing DiskSuite2-98 9. To verify that the system sees all SCSI devices, enter the following: probe-scsi-all The program responds similar to the following: 10. Verify that all of the SCSI devices are recognized. If the devices are still not recognized, see CentreVu® CMS Sun® Enterprise™ 3500 Computer Maintenance and Troubleshooting (585-215-875) for more information. 11. To verify that the system sees...
Page 117
Installing Software and Setting Up CMS CentreVu® CMS R3V8 Software Installation and Setup Installing DiskSuite2-99 13. When you have verified that the system is recognizing all of its devices, enter: setenv auto-boot? true If you fail to enter this command, future reboots will stop at the boot prompt instead of proceeding through the normal boot-up. 14. Enter boot -r. The system reboots. 15. Log in as root. 16. Repeat the procedures described in “Configuring DiskSuite on an unmirrored system” on...
Page 118
Installing Software and Setting Up CMS CentreVu® CMS R3V8 Software Installation and Setup Installing DiskSuite2-100 7. Enter: setenv auto-boot? false This keeps the system from rebooting when you do a reset. 8. Enter: reset-all The system resets and responds with the ok prompt. 9. To verify that the system sees all SCSI devices, enter the following: probe-scsi-all The program responds similar to the following: 10. Verify that all of the disk drives are recognized. If the devices are still not...
Page 119
Installing Software and Setting Up CMS CentreVu® CMS R3V8 Software Installation and Setup Installing DiskSuite2-101 11. Enter boot -r. The system reboots. 12. Log in as root. 13. Repeat the procedures described in “Configuring DiskSuite on an unmirrored system” on Page 2-88” or “Configuring DiskSuite on a mirrored system” on Page 2-93. Disk Recognition Errors on SPARCserver2 1. Reboot the system with an init 0 command. The system reboots and displays the ok prompt. 2. Turn off the system unit....
Page 120
Installing Software and Setting Up CMS CentreVu® CMS R3V8 Software Installation and Setup Installing DiskSuite2-102 8. Enter: reset The system resets and responds with the ok prompt. 9. To verify that the system sees all SCSI devices, enter the following: probe-scsi-all The program responds similar to the following: 10. Verify that all of the disk drives are recognized. If the devices are still not recognized, see CentreVu® CMS R3V8 Hardware Maintenance and Troubleshooting (585-210-919) for more...