Page 111

  Installing Software and Setting Up CMS CentreVu®  CMS R3V8 Software Installation and Setup
Installing DiskSuite2-93
10. To create and mount /cms, enter:
mkdir /cms
mount /cms
11. Enter: eject cdrom
Configuring 
DiskSuite on a 
mirrored system
2
This procedure configures DiskSuite on a unmirrored Enterprise 3000 or 
3500 system.
1. Enter:
stty erase 

(where  means “press/hold Control as you press H”)
The stty command sets up your backspace key as an actual 
backspace. If you do not enter this command,...

Page 112

  Installing Software and Setting Up CMS CentreVu®  CMS R3V8 Software Installation and Setup
Installing DiskSuite2-94
8. To reboot, enter:
/usr/sbin/shutdown -y -g0 -i0
When the ok prompt is displayed, enter:
boot -r 
When the reboot is finished, log in as root. 
9. To setup the /cms metadevices, enter the following commands: 
export PATH=$PATH:/olds:/usr/opt/SUNWmd/sbin
olds -mirrored -setup
The system should respond:
Success, /cms mirrored successfully
10. Enter the following commands:
mkdir /cms
mount...

Page 113

  Installing Software and Setting Up CMS CentreVu®  CMS R3V8 Software Installation and Setup
Installing DiskSuite2-95
Checking for Disk 
Recognition Errors
2
The procedures in the section will help you to diagnose problems with 
unrecognized disk drives. This procedure is different for the different 
hardware platforms.
Use this procedure only if the DiskSuite scripts indicate there is a 
disk recognition error. Do NOT do this as part of the normal 
installation procedure.
Disk Recognition 
Errors on...

Page 114

  Installing Software and Setting Up CMS CentreVu®  CMS R3V8 Software Installation and Setup
Installing DiskSuite2-96
9. To verify that the system sees all IDE devices, enter:
probe-ide
The program responds similar to the following:
10. To verify that the system sees all SCSI devices, enter:
probe-scsi-all
The program responds similar to the following:
11. Verify that all of the disk drives are recognized. If the devices are still 
not recognized, see 
CentreVu® CMS R3V8 Hardware Maintenance 
and...

Page 115

  Installing Software and Setting Up CMS CentreVu®  CMS R3V8 Software Installation and Setup
Installing DiskSuite2-97
13. Enter boot -r. The system reboots.
14. Log in as 
root.
15. Repeat the procedures described in “Configuring DiskSuite on an 
unmirrored system” on Page 2-88, or “Configuring DiskSuite on a 
mirrored system” on Page 2-93.
Disk Recognition 
Errors on 
Enterprise35002
1. Reboot the system with an init 0 command. The system reboots 
and displays the ok prompt.
2. Turn off the system...

Page 116

  Installing Software and Setting Up CMS CentreVu®  CMS R3V8 Software Installation and Setup
Installing DiskSuite2-98
9. To verify that the system sees all SCSI devices, enter the following:
probe-scsi-all
The program responds similar to the following:
10. Verify that all of the SCSI devices are recognized. If the devices are 
still not recognized, see 
CentreVu® CMS Sun® Enterprise™ 3500 
Computer Maintenance and Troubleshooting
 (585-215-875) for 
more information.
11. To verify that the system sees...

Page 117

  Installing Software and Setting Up CMS CentreVu®  CMS R3V8 Software Installation and Setup
Installing DiskSuite2-99
13. When you have verified that the system is recognizing all of its 
devices, enter:
setenv auto-boot? true
If you fail to enter this command, future reboots will stop at the 
boot prompt instead of proceeding through the normal boot-up.
14. Enter boot -r. The system reboots.
15. Log in as 
root.
16. Repeat the procedures described in “Configuring DiskSuite on an 
unmirrored system” on...

Page 118

  Installing Software and Setting Up CMS CentreVu®  CMS R3V8 Software Installation and Setup
Installing DiskSuite2-100
7. Enter:
setenv auto-boot? false
This keeps the system from rebooting when you do a reset.
8. Enter:
reset-all
The system resets and responds with the ok prompt. 
9. To verify that the system sees all SCSI devices, enter the following:
probe-scsi-all
The program responds similar to the following:
10. Verify that all of the disk drives are recognized. If the devices are still 
not...

Page 119

  Installing Software and Setting Up CMS CentreVu®  CMS R3V8 Software Installation and Setup
Installing DiskSuite2-101
11. Enter boot -r. The system reboots.
12. Log in as 
root.
13. Repeat the procedures described in “Configuring DiskSuite on an 
unmirrored system” on Page 2-88” or “Configuring DiskSuite on a 
mirrored system” on Page 2-93.
Disk Recognition 
Errors on 
SPARCserver2
1. Reboot the system with an init 0 command. The system reboots 
and displays the ok prompt.
2. Turn off the system unit....

Page 120

  Installing Software and Setting Up CMS CentreVu®  CMS R3V8 Software Installation and Setup
Installing DiskSuite2-102
8. Enter:
reset
The system resets and responds with the ok prompt. 
9. To verify that the system sees all SCSI devices, enter the following:
probe-scsi-all
The program responds similar to the following:
10. Verify that all of the disk drives are recognized. If the devices are still 
not recognized, see 
CentreVu® CMS R3V8 Hardware Maintenance 
and Troubleshooting
 (585-210-919) for more...