Diagnostic Error Code FRU/Action 015-036-XXX USB port Register error System board 015-040-XXX USB port IRQ failure 1. Run setup and check for conflicts 2. Flash the system. See “Flash update procedures” on page 207 3. System board 015-195-XXX USB port Test aborted by user Information only Re-start the test, if necessary 015-196-XXX USB port test halt, error threshold exceeded 1. Press F3 to review the log file 2. Re-start the test to reset the log file 015-197-XXX USB port test warning 1. Make sure the component that is called out is connected and/or enabled. See Chapter 6, “Using the Setup Utility,” on page 51 2. Re-run test 3. Replace the component that is called out in warning statement 4. Replace the component under test 015-198-XXX USB port test aborted 1. If a component is called out, make sure it is connected and/or enabled. See Chapter 6, “Using the Setup Utility,” on page 51 2. Flash the system and re-test. See “Flash update procedures” on page 207 3. Go to “Undetermined problems” on page 81 015-199-XXX USB port test failed, cause unknown 1. Go to “Undetermined problems” on page 81 2. Flash the system and re-test. See “Flash update procedures” on page 207 3. Replace component under function test 018-000-XXX PCI Card Test Passed No action 018-0XX-XXX PCI Card Failure 1. Riser card, if installed 2. System board 018-195-XXX PCI Card Test aborted by user 1. PCI card 2. Information only Re-start the test, if necessary 018-196-XXX PCI Card test halt, error threshold exceeded 1. Press F3 to review the log file 2. Re-start the test to reset the log file Chapter 7. Symptom-to-FRU Index 65
Diagnostic Error Code FRU/Action 018-197-XXX PCI Card test warning 1. Make sure the component that is called out is connected and/or enabled. See Chapter 6, “Using the Setup Utility,” on page 51 2. Re-run test 3. Replace the component that is called out in warning statement 4. Replace the component under test 018-198-XXX PCI Card test aborted 1. If a component is called out, make sure it is connected and/or enabled. See Chapter 6, “Using the Setup Utility,” on page 51 2. Flash the system and re-test. See “Flash update procedures” on page 207 3. Go to “Undetermined problems” on page 81 018-199-XXX PCI Card test failed, cause unknown 1. Go to “Undetermined problems” on page 81 2. Flash the system and re-test. See “Flash update procedures” on page 207 3. Replace component under function test 018-250-XXX PCI Card Services error 1. PCI card 2. Riser card, if installed 3. System board 020-000-XXX PCI Interface Test Passed No action 020-0XX-XXX PCI Interface error 1. PCI card 2. Riser card, if installed 3. System board 020-195-XXX PCI Test aborted by user Information only Re-start the test, if necessary 020-196-XXX PCI test halt, error threshold exceeded 1. Press F3 to review the log file 2. Re-start the test to reset the log file 020-197-XXX PCI test warning 1. Make sure the component that is called out is connected and/or enabled. See Chapter 6, “Using the Setup Utility,” on page 51 2. Re-run test 3. Replace the component that is called out in warning statement 4. Replace the component under test 66 Lenovo 3000 J Series
Diagnostic Error Code FRU/Action 020-198-XXX PCI test aborted 1. If a component is called out, make sure it is connected and/or enabled. See Chapter 6, “Using the Setup Utility,” on page 51 2. Flash the system and re-test. See “Flash update procedures” on page 207 3. Go to “Undetermined problems” on page 81 020-199-XXX PCI test failed, cause unknown 1. Go to “Undetermined problems” on page 81 2. Flash the system and re-test. See “Flash update procedures” on page 207 3. Replace component under function test 020-262-XXX PCI system error 1. PCI card 2. Riser card, if installed 3. System board 025-000-XXX IDE interface Test Passed No action 025-00X-XXX 025-01X-XXX IDE interface failure 1. IDE signal cable 2. Check power supply voltages 3. Reseat IDE signal cable 4. IDE device 5. System board 025-027-XXX IDE interface Configuration/Setup error 1. IDE signal cable 2. Flash the system. See “Flash update procedures” on page 207 3. Reseat IDE signal cable 4. IDE device 5. System board 025-02X-XXX 025-03X-XXX 025-04X-XXX IDE Interface failure 1. IDE signal cable 2. Check power supply 3. Reseat IDE signal cable 4. IDE device 5. System board 025-195-XXX IDE interface Test aborted by user Information only Re-start the test, if necessary 025-196-XXX IDE interface test halt, error threshold exceeded 1. Press F3 to review the log file 2. Re-start the test to reset the log file 025-197-XXX IDE interface test warning 1. Make sure the component that is called out is connected and/or enabled. See Chapter 6, “Using the Setup Utility,” on page 51 2. Re-run test 3. Replace the component that is called out in warning statement 4. Replace the component under test Chapter 7. Symptom-to-FRU Index 67
Diagnostic Error Code FRU/Action 025-198-XXX IDE interface test aborted 1. If a component is called out, make sure it is connected and/or enabled. See Chapter 6, “Using the Setup Utility,” on page 51 2. Flash the system and re-test. See “Flash update procedures” on page 207 3. Go to “Undetermined problems” on page 81 025-199-XXX IDE interface test failed, cause unknown 1. Go to “Undetermined problems” on page 81 2. Flash the system and re-test. See “Flash update procedures” on page 207 3. Replace component under function test 030-000-XXX SCSI interface Test Passed No action 030-00X-XXX 030-01X-XXX SCSI interface failure 1. SCSI signal cable 2. Check power supply 3. SCSI device 4. SCSI adapter card, if installed 5. System board 030-027-XXX SCSI interface Configuration/Setup error 1. SCSI signal cable 2. Flash the system. See “Flash update procedures” on page 207 3. SCSI device 4. SCSI adapter card, if installed 5. System board 030-03X-XXX 030-04X-XXX SCSI interface error 1. SCSI signal cable 2. Check power supply 3. SCSI device 4. SCSI adapter card, if installed 5. System board 030-195-XXX SCSI interface Test aborted by user Information only Re-start the test, if necessary 030-196-XXX SCSI interface test halt, error threshold exceeded 1. Press F3 to review the log file 2. Re-start the test to reset the log file 030-197-XXX SCSI interface test warning 1. Make sure the component that is called out is connected and/or enabled. See Chapter 6, “Using the Setup Utility,” on page 51 2. Re-run test 3. Replace the component that is called out in warning statement 4. Replace the component under test 68 Lenovo 3000 J Series
Diagnostic Error Code FRU/Action 030-198-XXX SCSI interface test aborted 1. If a component is called out, make sure it is connected and/or enabled. See Chapter 6, “Using the Setup Utility,” on page 51 2. Flash the system and re-test. See “Flash update procedures” on page 207 3. Go to “Undetermined problems” on page 81 030-199-XXX SCSI interface test failed, cause unknown 1. Go to “Undetermined problems” on page 81 2. Flash the system and re-test. See “Flash update procedures” on page 207 3. Replace component under function test 035-000-XXX RAID interface Test Passed No action 035-0XX-XXX RAID interface Failure 1. RAID signal cable 2. RAID device 3. RAID adapter card, if installed 4. System board 035-195-XXX RAID interface Test aborted by user Information only Re-start the test, if necessary 035-196-XXX RAID interface test halt, error threshold exceeded 1. Press F3 to review the log file 2. Re-start the test to reset the log file 035-197-XXX RAID interface test warning 1. Make sure the component that is called out is connected and/or enabled. See Chapter 6, “Using the Setup Utility,” on page 51 2. Re-run test 3. Replace the component that is called out in warning statement 4. Replace the component under test 035-198-XXX RAID interface test aborted 1. If a component is called out, make sure it is connected and/or enabled. See Chapter 6, “Using the Setup Utility,” on page 51 2. Flash the system and re-test. See “Flash update procedures” on page 207 3. Go to “Undetermined problems” on page 81 035-199-XXX RAID interface test failed, cause unknown 1. See “Undetermined problems” on page 81 2. Flash the system and re-test. See “Flash update procedures” on page 207 3. Replace component under function test 071-000-XXX Audio port Interface Test Passed No action Chapter 7. Symptom-to-FRU Index 69
Diagnostic Error Code FRU/Action 071-00X-XXX 071-01X-XXX 071-02X-XXX Audio port error 1. Run Setup 2. Flash the system. See “Flash update procedures” on page 207 3. System board 071-03X-XXX Audio port failure 1. Speakers 2. Microphone 3. Audio card, if installed 4. System board 071-04X-XXX Audio port failure 1. Run Setup 2. Audio card, if installed 3. System board 071-195-XXX Audio port Test aborted by user Information only Re-start the test, if necessary 071-196-XXX Audio port test halt, error threshold exceeded 1. Press F3 to review the log file 2. Re-start the test to reset the log file 071-197-XXX Audio port test warning 1. Make sure the component that is called out is connected and/or enabled. See Chapter 6, “Using the Setup Utility,” on page 51 2. Re-run test 3. Replace the component that is called out in warning statement 4. Replace the component under test 071-198-XXX Audio port test aborted 1. If a component is called out, make sure it is connected and/or enabled. See Chapter 6, “Using the Setup Utility,” on page 51 2. Flash the system and re-test. See “Flash update procedures” on page 207 3. Go to “Undetermined problems” on page 81 071-199-XXX Audio port test failed, cause unknown 1. See “Undetermined problems” on page 81 2. Flash the system and re-test. See “Flash update procedures” on page 207 3. Replace component under function test 071-25X-XXX Audio port failure 1. Speakers 2. Audio card, if installed 3. System board 080-000-XXX Game Port interface Test Passed No action 080-XXX-XXX Game Port interface Error 1. Remove the game port device and re-test the system 080-195-XXX Game Port interface Test aborted by user Information only Re-start the test, if necessary 70 Lenovo 3000 J Series
Diagnostic Error Code FRU/Action 080-196-XXX Game Port interface test halt, error threshold exceeded 1. Press F3 to review the log file 2. Re-start the test to reset the log file 080-197-XXX Game Port interface test warning 1. Make sure the component that is called out is connected and/or enabled. See Chapter 6, “Using the Setup Utility,” on page 51 2. Re-run test 3. Replace the component that is called out in warning statement 4. Replace the component under test 080-198-XXX Game Port interface test aborted 1. If a component is called out, make sure it is connected and/or enabled. See Chapter 6, “Using the Setup Utility,” on page 51 2. Flash the system and re-test. See “Flash update procedures” on page 207 3. Go to “Undetermined problems” on page 81 080-199-XXX Game Port interface test failed, cause unknown 1. See “Undetermined problems” on page 81 2. Flash the system and re-test. See “Flash update procedures” on page 207 3. Replace component under function test 086-000-XXX Mouse Port interface Test Passed No action 086-001-XXX Mouse Port interface Presence 1. Mouse 2. System board 086-032-XXX Mouse Port interface Device controller failure 1. Mouse 2. System board 086-035-XXX Mouse Port interface Reset 1. Mouse 2. System board 086-040-XXX Mouse Port interface IRQ failure 1. Run Setup 2. Mouse 3. System board 086-195-XXX Mouse Port interface Test aborted by user Information only Re-start the test, if necessary 086-196-XXX Mouse Port interface test halt, error threshold exceeded 1. Press F3 to review the log file 2. Re-start the test to reset the log file Chapter 7. Symptom-to-FRU Index 71
Diagnostic Error Code FRU/Action 086-197-XXX Mouse Port interface test warning 1. Make sure the component that is called out is connected and/or enabled. See Chapter 6, “Using the Setup Utility,” on page 51 2. Re-run test 3. Replace the component that is called out in warning statement 4. Replace the component under test 086-198-XXX Mouse Port interface test aborted 1. If a component is called out, make sure it is connected and/or enabled. See Chapter 6, “Using the Setup Utility,” on page 51 2. Flash the system and re-test. See “Flash update procedures” on page 207 3. Go to “Undetermined problems” on page 81 086-199-XXX Mouse Port interface test failed, cause unknown 1. See “Undetermined problems” on page 81 2. Flash the system and re-test. See “Flash update procedures” on page 207 3. Replace component under function test 089-000-XXX Microprocessor Test Passed No action 089-XXX-XXX Microprocessor failure 1. Microprocessor(s) 2. System board 089-195-XXX Microprocessor Test aborted by user Information only Re-start the test, if necessary 089-196-XXX Microprocessor test halt, error threshold exceeded 1. Press F3 to review the log file 2. Re-start the test to reset the log file 089-197-XXX Microprocessor test warning 1. Make sure the component that is called out is connected and/or enabled. See Chapter 6, “Using the Setup Utility,” on page 51 2. Re-run test 3. Replace the component that is called out in warning statement 4. Replace the component under test 089-198-XXX Microprocessor test aborted 1. Flash the system. See “Flash update procedures” on page 207 2. Go to “Undetermined problems” on page 81 089-199-XXX Microprocessor test failed, cause unknown 1. See “Undetermined problems” on page 81 2. Flash the system and re-test. See “Flash update procedures” on page 207 3. Replace component under function test 170-000-XXX Voltage Sensor(s) Test Passed No action 72 Lenovo 3000 J Series
Diagnostic Error Code FRU/Action 170-0XX-XXX Voltage Sensor(s) failure 1. Flash system 2. System board 170-195-XXX Voltage Sensor(s) Test aborted by user Information only Re-start the test, if necessary 170-196-XXX Voltage Sensor(s) test halt, error threshold exceeded 1. Press F3 to review the log file 2. Re-start the test to reset the log file 170-197-XXX Voltage Sensor(s) test warning 1. Make sure the component that is called out is connected and/or enabled. See Chapter 6, “Using the Setup Utility,” on page 51 2. Re-run test 3. Replace the component that is called out in warning statement 4. Replace the component under test 170-198-XXX Voltage Sensor(s) test aborted 1. If a component is called out, make sure it is connected and/or enabled. See Chapter 6, “Using the Setup Utility,” on page 51 2. Flash the system and re-test. See “Flash update procedures” on page 207 3. Go to “Undetermined problems” on page 81 170-199-XXX Voltage Sensor(s) test failed, cause unknown 1. See “Undetermined problems” on page 81 2. Flash the system and re-test. See “Flash update procedures” on page 207 3. Replace component under function test 170-250-XXX 170-251-XXX Voltage Sensor(s) Voltage limit error 1. Power supply 2. System board 170-254-XXX Voltage Sensor(s) Voltage Regulator Module error 1. Voltage Regulator Module (VRM) 2. Microprocessor 3. System board 175-000-XXX Thermal Sensor(s) Test Passed No action 175-0XX-XXX Thermal Sensor(s) failure 1. Flash system 2. System board 175-195-XXX Thermal Sensor(s) Test aborted by user Information only Re-start the test, if necessary 175-196-XXX Thermal Sensor(s) test halt, error threshold exceeded 1. Press F3 to review the log file 2. Re-start the test to reset the log file Chapter 7. Symptom-to-FRU Index 73
Diagnostic Error Code FRU/Action 175-197-XXX Thermal Sensor(s) test warning 1. Make sure the component that is called out is connected and/or enabled. See Chapter 6, “Using the Setup Utility,” on page 51 2. Re-run test 3. Replace the component that is called out in warning statement 4. Replace the component under test 175-198-XXX Thermal Sensor(s) test aborted 1. If a component is called out, make sure it is connected and/or enabled 2. Flash the system and re-test. See “Flash update procedures” on page 207 3. Go to “Undetermined problems” on page 81 175-199-XXX Thermal Sensor(s) test failed, cause unknown 1. See “Undetermined problems” on page 81 2. Flash the system and re-test. See “Flash update procedures” on page 207 3. Replace component under function test 175-250-XXX 175-251-XXX Thermal Sensor(s) limit error 1. Check fans 2. Check Power supply voltages 3. Microprocessor 4. System board 185-000-XXX Asset Security Test Passed No action 185-XXX-XXX Asset Security failure 1. Flash system 2. System board 185-278-XXX Asset Security Chassis Intrusion 1. Assure Asset Security Enabled 2. C2 Cover Switch 3. System board 201-000-XXX System Memory Test Passed No action 201-XXX-XXX System Memory error 1. Replace the memory module called out by the test 2. System board 202-000-XXX System Cache Test Passed No action 202-XXX-XXX System Cache error 1. Cache, if removable 2. System board 3. Microprocessor 206-000-XXX Diskette Drive Test Passed No action 206-XXX-XXX Diskette Drive error 1. Diskette Drive Cable 2. Check power supply voltages 3. Diskette drive 4. System board 74 Lenovo 3000 J Series