    							Diagnostic Error Code FRU/Action 
    015-036-XXX 
    USB port Register error 
    System board 
    015-040-XXX 
    USB port IRQ failure 1.   
     Run setup and check for conflicts 
    2. 
     
     Flash the system. See “Flash update 
    procedures” on page 207 
    3. 
     
     System board 
    015-195-XXX 
    USB port Test aborted by user 
    Information only 
    Re-start the test, if necessary 
    015-196-XXX 
    USB port test halt, error threshold exceeded 1. 
     
     Press F3 to review the log file 
    2. 
     
     Re-start the test to reset the log file 
    015-197-XXX 
    USB port test warning 1. 
     
     Make sure the component that is called 
    out is connected and/or enabled. See 
    Chapter 6, “Using the Setup Utility,” on 
    page 51 
    2. 
     
     Re-run test 
    3. 
     
     Replace the component that is called out 
    in warning statement 
    4. 
     
     Replace the component under test 
    015-198-XXX 
    USB port test aborted 1. 
     
     If a component is called out, make sure 
    it is connected and/or enabled. See 
    Chapter 6, “Using the Setup Utility,” on 
    page 51 
    2. 
     
     Flash the system and re-test. See “Flash 
    update procedures” on page 207 
    3. 
     
     Go to “Undetermined problems” on page 
    81 
    015-199-XXX 
    USB port test failed, cause unknown 1. 
     
     Go to “Undetermined problems” on page 
    81 
    2. 
     
     Flash the system and re-test. See “Flash 
    update procedures” on page 207 
    3. 
     
     Replace component under function test 
    018-000-XXX 
    PCI Card Test Passed 
    No action 
    018-0XX-XXX 
    PCI Card Failure 1. 
     
     Riser card, if installed 
    2. 
     
     System board 
    018-195-XXX 
    PCI Card Test aborted by user 1. 
     
     PCI card 
    2. 
     
     Information only 
    Re-start the test, if necessary 
    018-196-XXX 
    PCI Card test halt, error threshold exceeded 1. 
     
     Press F3 to review the log file 
    2. 
     
     Re-start the test to reset the log file 
     
    Chapter 7. Symptom-to-FRU Index 65 
    						
    							Diagnostic Error Code FRU/Action 
    018-197-XXX 
    PCI Card test warning 1.   
     Make sure the component that is called 
    out is connected and/or enabled. See 
    Chapter 6, “Using the Setup Utility,” on 
    page 51 
    2. 
     
     Re-run test 
    3. 
     
     Replace the component that is called out 
    in warning statement 
    4. 
     
     Replace the component under test 
    018-198-XXX 
    PCI Card test aborted 1. 
     
     If a component is called out, make sure 
    it is connected and/or enabled. See 
    Chapter 6, “Using the Setup Utility,” on 
    page 51 
    2. 
     
     Flash the system and re-test. See “Flash 
    update procedures” on page 207 
    3. 
     
     Go to “Undetermined problems” on page 
    81 
    018-199-XXX 
    PCI Card test failed, cause unknown 1. 
     
     Go to “Undetermined problems” on page 
    81 
    2. 
     
     Flash the system and re-test. See “Flash 
    update procedures” on page 207 
    3. 
     
     Replace component under function test 
    018-250-XXX 
    PCI Card Services error 1. 
     
     PCI card 
    2. 
     
     Riser card, if installed 
    3. 
     
     System board 
    020-000-XXX 
    PCI Interface Test Passed 
    No action 
    020-0XX-XXX 
    PCI Interface error 1. 
     
     PCI card 
    2. 
     
     Riser card, if installed 
    3. 
     
     System board 
    020-195-XXX 
    PCI Test aborted by user 
    Information only 
    Re-start the test, if necessary 
    020-196-XXX 
    PCI test halt, error threshold exceeded 1. 
     
     Press F3 to review the log file 
    2. 
     
     Re-start the test to reset the log file 
    020-197-XXX 
    PCI test warning 1. 
     
     Make sure the component that is called 
    out is connected and/or enabled. See 
    Chapter 6, “Using the Setup Utility,” on 
    page 51 
    2. 
     
     Re-run test 
    3. 
     
     Replace the component that is called out 
    in warning statement 
    4. 
     
     Replace the component under test 
     
    66 Lenovo 3000 J Series 
    						
    							Diagnostic Error Code FRU/Action 
    020-198-XXX 
    PCI test aborted 1.   
     If a component is called out, make sure 
    it is connected and/or enabled. See 
    Chapter 6, “Using the Setup Utility,” on 
    page 51 
    2. 
     
     Flash the system and re-test. See “Flash 
    update procedures” on page 207 
    3. 
     
     Go to “Undetermined problems” on page 
    81 
    020-199-XXX 
    PCI test failed, cause unknown 1. 
     
     Go to “Undetermined problems” on page 
    81 
    2. 
     
     Flash the system and re-test. See “Flash 
    update procedures” on page 207 
    3. 
     
     Replace component under function test 
    020-262-XXX
    PCI
     system error 1.   
     PCI card 
    2. 
     
     Riser card, if installed 
    3. 
     
     System board 
    025-000-XXX
    IDE
     interface Test Passed 
    No action 
    025-00X-XXX 
    025-01X-XXX 
    IDE interface failure 
    1.   
     IDE signal cable 
    2. 
     
     Check power supply voltages 
    3. 
     
     Reseat IDE signal cable 
    4. 
     
     IDE device 
    5. 
     
     System board 
    025-027-XXX 
    IDE interface Configuration/Setup error 1. 
     
     IDE signal cable 
    2. 
     
     Flash the system. See “Flash update 
    procedures” on page 207 
    3. 
     
     Reseat IDE signal cable 
    4. 
     
     IDE device 
    5. 
     
     System board 
    025-02X-XXX 
    025-03X-XXX 
    025-04X-XXX 
    IDE Interface failure 
    1. 
     
     IDE signal cable 
    2. 
     
     Check power supply 
    3. 
     
     Reseat IDE signal cable 
    4. 
     
     IDE device 
    5. 
     
     System board 
    025-195-XXX 
    IDE interface Test aborted by user 
    Information only 
    Re-start the test, if necessary 
    025-196-XXX 
    IDE interface test halt, error threshold 
    exceeded 
    1. 
     
     Press F3 to review the log file 
    2. 
     
     Re-start the test to reset the log file 
    025-197-XXX 
    IDE interface test warning 1. 
     
     Make sure the component that is called 
    out is connected and/or enabled. See 
    Chapter 6, “Using the Setup Utility,” on 
    page 51 
    2. 
     
     Re-run test 
    3. 
     
     Replace the component that is called out 
    in warning statement 
    4. 
     
     Replace the component under test 
     
    Chapter 7. Symptom-to-FRU Index 67 
    						
    							Diagnostic Error Code FRU/Action 
    025-198-XXX 
    IDE interface test aborted 1.   
     If a component is called out, make sure 
    it is connected and/or enabled. See 
    Chapter 6, “Using the Setup Utility,” on 
    page 51 
    2. 
     
     Flash the system and re-test. See “Flash 
    update procedures” on page 207 
    3. 
     
     Go to “Undetermined problems” on page 
    81 
    025-199-XXX 
    IDE interface test failed, cause unknown 1. 
     
     Go to “Undetermined problems” on page 
    81 
    2. 
     
     Flash the system and re-test. See “Flash 
    update procedures” on page 207 
    3. 
     
     Replace component under function test 
    030-000-XXX 
    SCSI interface Test Passed 
    No action 
    030-00X-XXX 
    030-01X-XXX 
    SCSI interface failure 
    1. 
     
     SCSI signal cable 
    2. 
     
     Check power supply 
    3. 
     
     SCSI device 
    4. 
     
     SCSI adapter card, if installed 
    5. 
     
     System board 
    030-027-XXX 
    SCSI interface Configuration/Setup error 1. 
     
     SCSI signal cable 
    2. 
     
     Flash the system. See “Flash update 
    procedures” on page 207 
    3. 
     
     SCSI device 
    4. 
     
     SCSI adapter card, if installed 
    5. 
     
     System board 
    030-03X-XXX 
    030-04X-XXX 
    SCSI interface error 
    1. 
     
     SCSI signal cable 
    2. 
     
     Check power supply 
    3. 
     
     SCSI device 
    4. 
     
     SCSI adapter card, if installed 
    5. 
     
     System board 
    030-195-XXX 
    SCSI interface Test aborted by user 
    Information only 
    Re-start the test, if necessary 
    030-196-XXX 
    SCSI interface test halt, error threshold 
    exceeded 
    1. 
     
     Press F3 to review the log file 
    2. 
     
     Re-start the test to reset the log file 
    030-197-XXX 
    SCSI interface test warning 1. 
     
     Make sure the component that is called 
    out is connected and/or enabled. See 
    Chapter 6, “Using the Setup Utility,” on 
    page 51 
    2. 
     
     Re-run test 
    3. 
     
     Replace the component that is called out 
    in warning statement 
    4. 
     
     Replace the component under test 
     
    68 Lenovo 3000 J Series 
    						
    							Diagnostic Error Code FRU/Action 
    030-198-XXX 
    SCSI interface test aborted 1.   
     If a component is called out, make sure 
    it is connected and/or enabled. See 
    Chapter 6, “Using the Setup Utility,” on 
    page 51 
    2. 
     
     Flash the system and re-test. See “Flash 
    update procedures” on page 207 
    3. 
     
     Go to “Undetermined problems” on page 
    81 
    030-199-XXX 
    SCSI interface test failed, cause unknown 1. 
     
     Go to “Undetermined problems” on page 
    81 
    2. 
     
     Flash the system and re-test. See “Flash 
    update procedures” on page 207 
    3. 
     
     Replace component under function test 
    035-000-XXX 
    RAID interface Test Passed 
    No action 
    035-0XX-XXX 
    RAID interface Failure 1. 
     
     RAID signal cable 
    2. 
     
     RAID device 
    3. 
     
     RAID adapter card, if installed 
    4. 
     
     System board 
    035-195-XXX 
    RAID interface Test aborted by user 
    Information only 
    Re-start the test, if necessary 
    035-196-XXX 
    RAID interface test halt, error threshold 
    exceeded 
    1. 
     
     Press F3 to review the log file 
    2. 
     
     Re-start the test to reset the log file 
    035-197-XXX 
    RAID interface test warning 1. 
     
     Make sure the component that is called 
    out is connected and/or enabled. See 
    Chapter 6, “Using the Setup Utility,” on 
    page 51 
    2. 
     
     Re-run test 
    3. 
     
     Replace the component that is called out 
    in warning statement 
    4. 
     
     Replace the component under test 
    035-198-XXX 
    RAID interface test aborted 1. 
     
     If a component is called out, make sure 
    it is connected and/or enabled. See 
    Chapter 6, “Using the Setup Utility,” on 
    page 51 
    2. 
     
     Flash the system and re-test. See “Flash 
    update procedures” on page 207 
    3. 
     
     Go to “Undetermined problems” on page 
    81 
    035-199-XXX 
    RAID interface test failed, cause unknown 1. 
     
     See “Undetermined problems” on page 
    81 
    2. 
     
     Flash the system and re-test. See “Flash 
    update procedures” on page 207 
    3. 
     
     Replace component under function test 
    071-000-XXX 
    Audio port Interface Test Passed 
    No action 
     
    Chapter 7. Symptom-to-FRU Index 69 
    						
    							Diagnostic Error Code FRU/Action 
    071-00X-XXX 
    071-01X-XXX 
    071-02X-XXX
    Audio
     port error 
    1.   
     Run Setup 
    2. 
     
     Flash the system. See “Flash update 
    procedures” on page 207 
    3. 
     
     System board 
    071-03X-XXX 
    Audio port failure 1. 
     
     Speakers 
    2. 
     
     Microphone 
    3. 
     
     Audio card, if installed 
    4. 
     
     System board 
    071-04X-XXX 
    Audio port failure 1. 
     
     Run Setup 
    2. 
     
     Audio card, if installed 
    3. 
     
     System board 
    071-195-XXX 
    Audio port Test aborted by user 
    Information only 
    Re-start the test, if necessary 
    071-196-XXX 
    Audio port test halt, error threshold 
    exceeded 
    1. 
     
     Press F3 to review the log file 
    2. 
     
     Re-start the test to reset the log file 
    071-197-XXX 
    Audio port test warning 1. 
     
     Make sure the component that is called 
    out is connected and/or enabled. See 
    Chapter 6, “Using the Setup Utility,” on 
    page 51 
    2. 
     
     Re-run test 
    3. 
     
     Replace the component that is called out 
    in warning statement 
    4. 
     
     Replace the component under test 
    071-198-XXX 
    Audio port test aborted 1. 
     
     If a component is called out, make sure 
    it is connected and/or enabled. See 
    Chapter 6, “Using the Setup Utility,” on 
    page 51 
    2. 
     
     Flash the system and re-test. See “Flash 
    update procedures” on page 207 
    3. 
     
     Go to “Undetermined problems” on page 
    81 
    071-199-XXX 
    Audio port test failed, cause unknown 1. 
     
     See “Undetermined problems” on page 
    81 
    2. 
     
     Flash the system and re-test. See “Flash 
    update procedures” on page 207 
    3. 
     
     Replace component under function test 
    071-25X-XXX 
    Audio port failure 1. 
     
     Speakers 
    2. 
     
     Audio card, if installed 
    3. 
     
     System board 
    080-000-XXX 
    Game Port interface Test Passed 
    No action 
    080-XXX-XXX 
    Game Port interface Error 1. 
     
     Remove the game port device and 
    re-test the system 
    080-195-XXX 
    Game Port interface Test aborted by user 
    Information only 
    Re-start the test, if necessary 
     
    70 Lenovo 3000 J Series 
    						
    							Diagnostic Error Code FRU/Action 
    080-196-XXX 
    Game Port interface test halt, error threshold 
    exceeded 
    1.   
     Press F3 to review the log file 
    2. 
     
     Re-start the test to reset the log file 
    080-197-XXX 
    Game Port interface test warning 1. 
     
     Make sure the component that is called 
    out is connected and/or enabled. See 
    Chapter 6, “Using the Setup Utility,” on 
    page 51 
    2. 
     
     Re-run test 
    3. 
     
     Replace the component that is called out 
    in warning statement 
    4. 
     
     Replace the component under test 
    080-198-XXX 
    Game Port interface test aborted 1. 
     
     If a component is called out, make sure 
    it is connected and/or enabled. See 
    Chapter 6, “Using the Setup Utility,” on 
    page 51 
    2. 
     
     Flash the system and re-test. See “Flash 
    update procedures” on page 207 
    3. 
     
     Go to “Undetermined problems” on page 
    81 
    080-199-XXX 
    Game Port interface test failed, cause 
    unknown 
    1. 
     
     See “Undetermined problems” on page 
    81 
    2. 
     
     Flash the system and re-test. See “Flash 
    update procedures” on page 207 
    3. 
     
     Replace component under function test 
    086-000-XXX 
    Mouse Port interface Test Passed 
    No action 
    086-001-XXX 
    Mouse Port interface Presence 1. 
     
     Mouse 
    2. 
     
     System board 
    086-032-XXX 
    Mouse Port interface Device controller 
    failure 
    1. 
     
     Mouse 
    2. 
     
     System board 
    086-035-XXX 
    Mouse Port interface Reset 1. 
     
     Mouse 
    2. 
     
     System board 
    086-040-XXX 
    Mouse Port interface IRQ failure 1. 
     
     Run Setup 
    2. 
     
     Mouse 
    3. 
     
     System board 
    086-195-XXX 
    Mouse Port interface Test aborted by user 
    Information only 
    Re-start the test, if necessary 
    086-196-XXX 
    Mouse Port interface test halt, error 
    threshold exceeded 
    1. 
     
     Press F3 to review the log file 
    2. 
     
     Re-start the test to reset the log file 
     
    Chapter 7. Symptom-to-FRU Index 71 
    						
    							Diagnostic Error Code FRU/Action 
    086-197-XXX 
    Mouse Port interface test warning 1.   
     Make sure the component that is called 
    out is connected and/or enabled. See 
    Chapter 6, “Using the Setup Utility,” on 
    page 51 
    2. 
     
     Re-run test 
    3. 
     
     Replace the component that is called out 
    in warning statement 
    4. 
     
     Replace the component under test 
    086-198-XXX 
    Mouse Port interface test aborted 1. 
     
     If a component is called out, make sure 
    it is connected and/or enabled. See 
    Chapter 6, “Using the Setup Utility,” on 
    page 51 
    2. 
     
     Flash the system and re-test. See “Flash 
    update procedures” on page 207 
    3. 
     
     Go to “Undetermined problems” on page 
    81 
    086-199-XXX 
    Mouse Port interface test failed, cause 
    unknown 
    1. 
     
     See “Undetermined problems” on page 
    81 
    2. 
     
     Flash the system and re-test. See “Flash 
    update procedures” on page 207 
    3. 
     
     Replace component under function test 
    089-000-XXX 
    Microprocessor Test Passed 
    No action 
    089-XXX-XXX 
    Microprocessor failure 1. 
     
     Microprocessor(s) 
    2. 
     
     System board 
    089-195-XXX 
    Microprocessor Test aborted by user 
    Information only 
    Re-start the test, if necessary 
    089-196-XXX 
    Microprocessor test halt, error threshold 
    exceeded 
    1. 
     
     Press F3 to review the log file 
    2. 
     
     Re-start the test to reset the log file 
    089-197-XXX 
    Microprocessor test warning 1. 
     
     Make sure the component that is called 
    out is connected and/or enabled. See 
    Chapter 6, “Using the Setup Utility,” on 
    page 51 
    2. 
     
     Re-run test 
    3. 
     
     Replace the component that is called out 
    in warning statement 
    4. 
     
     Replace the component under test 
    089-198-XXX 
    Microprocessor test aborted 1. 
     
     Flash the system. See “Flash update 
    procedures” on page 207 
    2. 
     
     Go to “Undetermined problems” on page 
    81 
    089-199-XXX 
    Microprocessor test failed, cause unknown 1. 
     
     See “Undetermined problems” on page 
    81 
    2. 
     
     Flash the system and re-test. See “Flash 
    update procedures” on page 207 
    3. 
     
     Replace component under function test 
    170-000-XXX 
    Voltage Sensor(s) Test Passed 
    No action 
     
    72 Lenovo 3000 J Series 
    						
    							Diagnostic Error Code FRU/Action 
    170-0XX-XXX 
    Voltage Sensor(s) failure 1.   
     Flash system 
    2. 
     
     System board 
    170-195-XXX 
    Voltage Sensor(s) Test aborted by user 
    Information only 
    Re-start the test, if necessary 
    170-196-XXX 
    Voltage Sensor(s) test halt, error threshold 
    exceeded 
    1. 
     
     Press F3 to review the log file 
    2. 
     
     Re-start the test to reset the log file 
    170-197-XXX 
    Voltage Sensor(s) test warning 1. 
     
     Make sure the component that is called 
    out is connected and/or enabled. See 
    Chapter 6, “Using the Setup Utility,” on 
    page 51 
    2. 
     
     Re-run test 
    3. 
     
     Replace the component that is called out 
    in warning statement 
    4. 
     
     Replace the component under test 
    170-198-XXX 
    Voltage Sensor(s) test aborted 1. 
     
     If a component is called out, make sure 
    it is connected and/or enabled. See 
    Chapter 6, “Using the Setup Utility,” on 
    page 51 
    2. 
     
     Flash the system and re-test. See “Flash 
    update procedures” on page 207 
    3. 
     
     Go to “Undetermined problems” on page 
    81 
    170-199-XXX 
    Voltage Sensor(s) test failed, cause unknown 1. 
     
     See “Undetermined problems” on page 
    81 
    2. 
     
     Flash the system and re-test. See “Flash 
    update procedures” on page 207 
    3. 
     
     Replace component under function test 
    170-250-XXX 
    170-251-XXX 
    Voltage Sensor(s) Voltage limit error 
    1. 
     
     Power supply 
    2. 
     
     System board 
    170-254-XXX 
    Voltage Sensor(s) Voltage Regulator Module 
    error 
    1. 
     
     Voltage Regulator Module (VRM) 
    2. 
     
     Microprocessor 
    3. 
     
     System board 
    175-000-XXX 
    Thermal Sensor(s) Test Passed 
    No action 
    175-0XX-XXX 
    Thermal Sensor(s) failure 1. 
     
     Flash system 
    2. 
     
     System board 
    175-195-XXX 
    Thermal Sensor(s) Test aborted by user 
    Information only 
    Re-start the test, if necessary 
    175-196-XXX 
    Thermal Sensor(s) test halt, error threshold 
    exceeded 
    1. 
     
     Press F3 to review the log file 
    2. 
     
     Re-start the test to reset the log file 
     
    Chapter 7. Symptom-to-FRU Index 73 
    						
    							Diagnostic Error Code FRU/Action 
    175-197-XXX 
    Thermal Sensor(s) test warning 1.   
     Make sure the component that is called 
    out is connected and/or enabled. See 
    Chapter 6, “Using the Setup Utility,” on 
    page 51 
    2. 
     
     Re-run test 
    3. 
     
     Replace the component that is called out 
    in warning statement 
    4. 
     
     Replace the component under test 
    175-198-XXX 
    Thermal Sensor(s) test aborted 1. 
     
     If a component is called out, make sure 
    it is connected and/or enabled 
    2. 
     
     Flash the system and re-test. See “Flash 
    update procedures” on page 207 
    3. 
     
     Go to “Undetermined problems” on page 
    81 
    175-199-XXX 
    Thermal Sensor(s) test failed, cause 
    unknown 
    1. 
     
     See “Undetermined problems” on page 
    81 
    2. 
     
     Flash the system and re-test. See “Flash 
    update procedures” on page 207 
    3. 
     
     Replace component under function test 
    175-250-XXX 
    175-251-XXX 
    Thermal Sensor(s) limit error 
    1. 
     
     Check fans 
    2. 
     
     Check Power supply voltages 
    3. 
     
     Microprocessor 
    4. 
     
     System board 
    185-000-XXX 
    Asset Security Test Passed 
    No action 
    185-XXX-XXX 
    Asset Security failure 1. 
     
     Flash system 
    2. 
     
     System board 
    185-278-XXX 
    Asset Security Chassis Intrusion 1. 
     
     Assure Asset Security Enabled 
    2. 
     
     C2 Cover Switch 
    3. 
     
     System board 
    201-000-XXX 
    System Memory Test Passed 
    No action 
    201-XXX-XXX 
    System Memory error 1. 
     
     Replace the memory module called out 
    by the test 
    2. 
     
     System board 
    202-000-XXX 
    System Cache Test Passed 
    No action 
    202-XXX-XXX 
    System Cache error 1. 
     
     Cache, if removable 
    2. 
     
     System board 
    3. 
     
     Microprocessor 
    206-000-XXX 
    Diskette Drive Test Passed 
    No action 
    206-XXX-XXX 
    Diskette Drive error 1. 
     
     Diskette Drive Cable 
    2. 
     
     Check power supply voltages 
    3. 
     
     Diskette drive 
    4. 
     
     System board 
     
    74 Lenovo 3000 J Series 
    						