Page 331

4Specifying Settings Using PageScope Web Connection
4-60 bizhub 500/420
Specifying Settings Using PageScope Web Connection
Chapter 4
4.16 Administrator Password
The administrator password can be changed.
!
Detail 
The use of an application registered is available only when the following 
two conditions are met.
To change the administrator password
1On the System tab, click [Administrator Password].
2Type in the new administrator password, and then click the [Apply].
Downloaded From ManualsPrinter.com...

Page 332

Specifying Settings Using PageScope Web Connection4
bizhub 500/420 4-61
Specifying Settings Using PageScope Web Connection
Chapter 4
4.17 Application Registration
When using an application, such as Right Fax Server that is registered on an 
external server, you can register the settings and server address of the ap-
plication. By registering an application and server, you can automatically 
connect to and use the server of the application that was selected.
2
Note 
The use of an application registered is...

Page 333

4Specifying Settings Using PageScope Web Connection
4-62 bizhub 500/420
Specifying Settings Using PageScope Web Connection
Chapter 4
For Fax with Account
For Secure Docs
For Certified Delivery
No.Button nameFunction nameKeyboard 
typeDefault 
valueOption 
setting
1 Sender Name (CS) Name ASCII - -
2 User ID ID ASCII Walkup -
3 Password Password ASCII - -
4 Password Auth# Authentication - - None
5 Subject Subject ASCII - -
6 Billing Code 1 BillingCode1 ASCII - -
7 Billing Code 2 BillingCode2 ASCII - -
8...

Page 334

Specifying Settings Using PageScope Web Connection4
bizhub 500/420 4-63
Specifying Settings Using PageScope Web Connection
Chapter 4
New Registration Items of an Application
When registering an application, the items that can be input are described 
below.
In addition, enter the settings described below to specify custom items.
8 Document PW DocumentPassword ASCII - -
9 Delivery Method Delivery - - Certified
No.Button nameFunction nameKeyboard 
typeDefault 
valueOption 
setting
No. Displays the...

Page 335

4Specifying Settings Using PageScope Web Connection
4-64 bizhub 500/420
Specifying Settings Using PageScope Web Connection
Chapter 4
You can specify the details of each function button as described below.
2
Note 
The number of characters that can be input in the default value may vary 
depending on the function that was selected.
No. Displays the number of the item that was selected.
Button Name Enter the button name (up to 16 characters).
Function Name Select ID, Name, GeneralFaxNumber,...

Page 336

Specifying Settings Using PageScope Web Connection4
bizhub 500/420 4-65
Specifying Settings Using PageScope Web Connection
Chapter 4
To register an application
1Select the application to be registered and click the [Registration/Edit] 
button.
– “Not Registered” is displayed for applications that are not regis-
tered.
2Select the template type, and then click the [Next] button.
Downloaded From ManualsPrinter.com Manuals 

Page 337

4Specifying Settings Using PageScope Web Connection
4-66 bizhub 500/420
Specifying Settings Using PageScope Web Connection
Chapter 4
3Specify the application settings, and then click the [Next] button.
4Specify the settings of the button custom items.
Downloaded From ManualsPrinter.com Manuals 

Page 338

Specifying Settings Using PageScope Web Connection4
bizhub 500/420 4-67
Specifying Settings Using PageScope Web Connection
Chapter 4
5Click   to specify the details of each function. When the settings are 
specified, click the [Apply] button.
6Click the [Apply] button.
7Click the [OK] button.
Downloaded From ManualsPrinter.com Manuals 

Page 339

4Specifying Settings Using PageScope Web Connection
4-68 bizhub 500/420
Specifying Settings Using PageScope Web Connection
Chapter 4
Items that can Be Specified in Edit Application
You can specify the settings for each item described below in Edit Applica-
tion.
Application Setting
No. Displays the application registration number that was 
selected.
Application Name Enter the application name (up to 16 characters).
Downloaded From ManualsPrinter.com Manuals 

Page 340

Specifying Settings Using PageScope Web Connection4
bizhub 500/420 4-69
Specifying Settings Using PageScope Web Connection
Chapter 4
Sever Setting
Host Address Enter the host address of the server that is registered to the 
application (up to 15 characters).
File Path Enter the application file path (up to 96 characters).
User ID Enter the user ID for logging in to the server (up to 47 
characters).
Password Enter the password for logging in to the server (up to 31 
characters).
anonymous Select whether...