Page 111
INTER-TEL4PRACTIcEs IMX/GMX 416/832 INSTALLATION & MAINTENANCE INSTALLATION Issue 1. November 1994 FIGURE 3-17. SLC BLOCK CABLE TERMINATIONS MODULAR ASSEMBLY LINE CARD L SI m V/U Sff MODULAR JACK SEMBLY TO SINGLE- LINE SET OR PLAYBACK I ; DEVICE AMPHENOL- TYPE CONNECTOR CONNECTOR 66Ml-50.TYPE 66Ml-50.TYPE BLOCK BLOCK (PART OF MDF) (PART OF MDF) NOTE: For simplicity, this figure shows single-line sets and playback devices being installed using one-pair cable and four-conductor...
Page 112
INS’lALLATION Issue 1, November 1994 INTER-TELPRACTICES IMX/GMX 416/832 INSTALLATION & MAINTENANCE’ FIGURE 3-18. IDC BLOCK CABLE TERMINATIONS INWARD DIALING CARD np- wleL np JACK 1.1 1,- RING - ASSEMBLY I np- - npA MODULAR TO OFF-PREM- ISES STATION, SINGLE-LINE SE& OR PLAY- BACK DEVICE MODULAR J. - -- -- ACENABLE- 1.1 1,- AMPHENOL- I’ -48v- TYPE -- cyIouNl - CONNECTOR -- - - I$ 8 L TOOFF-PREM- ANY OF THE EIGHT IDC ClRCUlTS CAN BE STRAPPED FOR AC-RINGING ElTHER HERE ON THE...
Page 113
INTER-TELPRACTICES lNSlXLLATION IMX/GMX 416/832 INSTALLATION & MAINTENANCE Issue 1, November 1994 FIGURE 3-19. STATION CABLE TERMINATIONS ON THE STATION BLOCK 26 W - BL CIcrlTrP CKT 1+3oVDC CKTlTlP CKrlTIP 1 BL - W CKTlRING CKTlGND CKTlRING CKl-1RING 27 w-o CKT2TIe CKT 1 PRIMARY PATH CKr2l-v CKT2TIP 2 0 - w CKT2RING CKT 1 PRIMARY Pm CKT2RING CKT2RING 28 W-G cKT3lI.P CKT 1 SECONDARY PATH cKT3TIP cKr3TIP 3 G - W CKT3RING CKr 1 SECONDARY PATH CKT3RING CKT3RlNG 29 w-BR cKT4TIP CKT2+3ovDC...
Page 114
INS’lALLATION Issue 1. November 1994 INTER-TELPRACTICES IMX/GMX 416/832 INSTALLATION & MAINTENANCE D. STATION LOOP RESISTANCE TEST 5.18 Perform the loop resistance test for each station cable individually. (1) Ensure that bridging clips have not been installed on the station blocks and that the station instrument is not connected to the modular jack assembly. (2) Place a short across the RED and GREEN wires on the modular jack assembly. (3) At the MDF, measure the resistance across the...
Page 115
INTEFbTELPRACTICES Ih4WGM.X 416/832 INSTALLATION & MAINTENANCE INSTALLATION Issue 1. November 1994 E. CONNECTING OPTIONAL OFF-PREMISES EXTENSIONS (OPXs) 5.19 Off-premises extensions are remote ESLSs, SLIs, or single-line DTMF sets that are connected to the 416/832 System through telephone company OPX cir- cuits (or customer-provided circuits). At the MDF, the circuits are connected to Inward Dialing Cards (IDCs). NOTE: IDCs do not support message waiting applica- tions. If single-line sets...
Page 116
INSTALLATION Issue 1, November 1994 INTER-TELPRACTICES IMX/GMX 416/832 INSTALJATION & MAINTENANCE FIGURE 3-20. MATFUX CARD (MXC) CABLE TERMINATIONS 7 MATRIX CARD 41 r MXC (PART OF MDF) AMPHENOL- TYPE CONNECTOR - - - 3 BGNI (NOTIJBEO) -23 BOND (NOTUBEO) Jr -4 RlA-NC(UsEDlNTERN4LLYFORP!TREL4YJ Jr -33 OGNO (UBEC INTERNALLY FOR PFr RELAY) L -6 CAYCTHRU (U6EC INTERNALLY FOR PFTRELAYI z - 31 BWD (NOTUSED) A -6 RlB-NC Jr RELAY1 -32 RIB-C 1’ wLz?E -7 RlB-NO TRANsm L -33 BON)...
Page 117
INTER-TELPRACTICES IMX/GMX 416/832 INSTALLATION & MAINTENANCE INSTALCATON Issue 1, November 1994 FIGURE 3-20. MATRIX CARD (MXC) CABLE TERMINATIONS (CONT’D) MXC (CONTINUED FROM THE PREVIOUS PAGE) - MATRIX CARD 16 ,, . 26 & +-l -- BW (NOTUBED) -- BON) (NOTUBED) -- BON) (NOTUSED) I AMPHENOL- TYPE CONNECTOR B&V-------:--4 BOND (NQTUS~) ---- -- v/s - -60 BINGLE-LINE PORT-TIP ---- -- Bh’ SINGLE-LINE FOFIT RING MODEM - I -26 - CARD -- - -- -- -- BOM (NUTUSED) -- BciM...
Page 118
INSTALLATION Issue 1, November 1994 INTER-TELPRAcTIcE!3 IMX/GMX 416/832 INSTALLATION & MAINTENANCE G. CONNECTING THE EXP~SION (EXP) CARDTOTHEMDF 5.26 The EXP Card is terminated at the MDF so that it can be connected to a variety of optional equipment, in- cluding signaling devices, night transfer equipment, etc. Connect the EXP Card to the MDF as follows: (1) Using enough 2!5-pair cable to run from the EXP terminal block to the EXP Card in the expansion cabinet, make a termination cable....
Page 119
INTER-TELPRACTICES IMX/GMX 416/832 INSTALLATION 81 MAINTENANCE INSTALLATION Issue 1. November 1994 FIGURE 3-21. EXFWNSION (EXP) CARD CABLE TERMINATIONS L 2f CZLD 41 r AMPHENOL- TYPE CONNECTOR (PARTF MDF) REUY 1 -7 RlB-MO - I -33 BON) (NOTUSED) -tW FES-C - - 11 R20-No - - 37 BoM (NoTu=s - - - - - A - 12 Ri44c Jr- . -38 WA-C r - 13 RM-No Jr -32 BQN) (NoT=w Jr- - 14 luB-NC Jr -40 R3B-c ? RELAYS ---- ---- SBK - SBK - 16 16 Fm-No Fm-No YBL - YBL - - 41 - 41...
Page 120
INSTALLATION Issue 1, November 1994 wrER-TELPRAcTrcES IMIVGMX 416/832 INSTALLATION 8z MAINTENANCE FIGURE 3-21. EXPANSION (EXP) CARD CABLE TERMINATIONS (CONT’D) L 1t 2E r (CONTINUED FROM THE PREVIOUS PAGE)