Page 51
INSTALLATION Issue 2, May 1990 INTER-TEL PRACTICES GMX-48 INSTALLATION & MAINTENANCE FIGURE 3-5. STANDARD STATION CABLE TERMINATIONS ON THE STATION BLOCK AMPHENOL CABI F PAIR KCB & EXP* iv!M 26 1 27 2 28 3 CKT 1 + 30VDC CKTlTIP CKT 1 GND CKT 1 RING CKT 1 PRIMARY PATH CKT 1 GND” CKT 1 PRIMARY PATH CKT 1 GND” CKT 1 AUXILIARY PATH CKT 1 GND” CKT 1 AUXILIARY PATH CKT 1 GND” 29 4 30 5 31 6 W - BL BL - W w-o 0 - w W-G G - w W - BR BR- W w - S s-w R - BL BL - R CKT 2 +...
Page 52
INTER-TEL PRACTICES GMX-48 INSTALLATION & MAINTENANCE INSTALLATION Issue 2, May 1990 FIGURE 3-6. STANDARD TERMINATION OF UNUSED KEYSET CIRCUITS KCB OR EXP 1.1 1 I I I-- 1.1 I + 30VDCfi , .2 -- BRIDGING CLIPS Strap ground to pri- mary pair for unused keyset circuits 66Ml-50-TYPE BLOCK (PART OF MDF) NOTE: To later install a station instrument on an unused keyset circuit that has been termi- nated as shown above, first remove the termination strap. Page 3-13
Page 53
INSTALLATION INTER-TEL PRACTICES Issue 2, May 1990 GMX-48 INSTALLATION & MAINTENANCE D. SECONDARY VOICE PATH INSTALLATION 4.13 If desired, the system can be configured to al- low 24-line keyset users to receive off-hook voice an- nounce (OHVA) calls and/or to use the simultaneous voice/data communication feature. To accomplish this, the keyset is installed on an odd-numbered sta- tion circuit (e.g., 1.1, 1.3, 1.5, etc.). Then, the follow- ing even-numbered circuit (1.2, 1.4, 1.6, etc.) is...
Page 54
INTER-TEL PRACTICES GMX-48 INSTALLATION & MAINTENANCE INSTALLATION Issue 2, May 1990 FIGURE 3-7. STATION CABLE TERMINATIONS FOR SECONDARY VOICE PATH KEYSETS BRIDGING CLIPS TO BE INSTALLED MDF STATION BLOCK / STATION AMPHENOL CONNECTOR I STRAP UNUSED AUX PAIR TO GROUND NOTE: For proper keyset operation, all three pairs (power/ground, primary, and secondary) are required. Page 3-15
Page 55
INSTALLATION INTER-TEL PRACTICES Issue 2, May 1990 GMX.48 INSTALLATION & MAINTENANCE FIGURE 3-8. STN BLOCK TERMINATIONS FOR SECONDARY VOICE PATH KEYSETS AMPHENOL CABLE PAIR KCB OR EXP 26 W - BL CKT 1 + 3oVDc 1 BL - W CKT 1 GND 27 w-o CKT 1 PRIMARY PATH 2 0 - w ‘XT 1 PRIMARY PATH 28 W - G NOT USED 3 G - W NOT USED 29 W - BR NOT USED 4 BR- W NOT USED 30 w-s CKT 1 SECONDARY PATH 5 S-W CKT 1 SECONDARY PATH 31 R - BL NOT USED 6 BL - R NOT USED 32 R - 0 CKT 3 + 3oVDc 7 0 - R...
Page 56
INTER-TEL PRACTICES GMX-48 INSTALLATION & MAINTENANCE INSTALLATION Issue 2, May 1990 E. STATION LOOP RESISTANCE TEST 4.19 Perform the loop resistance test for each sta- tion cable individually. (1) (2) (3) Ensure that bridging clips have not been in- stalled on the STN blocks and that the station instrument is not connected to the modular jack assembly. Repeat this test for each station cable. Place a short across the RED and GREEN wires on the modular jack assembly. (4) (9 (6) Remove...
Page 57
INSTALLATION Issue 2, May 1990 ‘. INTER-TEL PRACTICES GMX-48 INSTALLATION & MAINTENANCE F. CONNECTING OPTIONAL OFF-PREMISES Information on operating and adjusting the repeater STATIONS unit is included with the product. 4.20 To connect off-premises single-line stations to the system, use AC ringer-equipped SLIs or single- line DTMF sets. 4.26 Install the off-premises stations as follows (re- fer to Figure 3-9 on page 3-20): 4.21 Off-premises stations require an external High Voltage Ringing...
Page 58
INTER-TEL PRACTICES GMX-48 INSTALLATION & MAINTENANCE INSTALLATION Issue 2, May 1990 a. b. Terminate one end of the cross-connect cable on the right side of the APM block on the pins associated with the off-premises station’s circuit. Terminate the other end of the cross-con- nect cable on the right side of the HVRA block on the W/BL or R/BL pairs (depend- ing on the HVRA circuit being used). NOTE: Be sure tip and ring connections are made as shown in Figure 3-9. Revers- ing tip and ring on...
Page 59
INSTALLATION Issue 2, May 1990 ‘. INTER-TEL PRACTICES GMX-48 INSTALLATION & MAINTENANCE FIGURE 3-9. HVRA CONNECTION TO THE MDF HVRA TERMINAL BLOCK OPX (7) LINE FROM APM TERMINAL BLOCK ---- _--- ---- UNIT -1 HVRA u _--- ---- ---- ---- ---- ---- ---- ---- ---- ---- Page 3-20
Page 60
INTER-TEL PRACTICES GMX-48 INSTALLATION & MAINTENANCE ‘.. INSTALLATION Issue 2, May 1990 5. 5.1 TERMINATING C.O. LINES AT THE MDF The installation procedure used to terminate C.O. lines at the MDF is dependent on the type of termination used by the telephone company and how close it is to the MDF. The C.O. lines may be termi- nated on RJ-type jacks or on an RJ-type block. 5.2 Follow one of the three C.O. termination meth- ods (A, B, or C) outlined on the following pages. IMPORTANT NOTES:...