Page 51
INTER-TEL PRACTICES GLX-PLUS INSTALLATION & MAINTENANCE INSTALLATION Issue 2, June 1993 FIGURE 3-15. GLX-PLUS KEYSET LCD INSTALLATION FACEPLATE ASSEMBLY (INSIDE VIEW) DISPLAY WINDOW LCD CONNECTOR RIBBON CABLE LCD UNIT CONTROL BOARD Page 3-23
Page 52
INSTALLATION Issue 2, June 1993 INTER-TEL PRACTICES GLX-PLUS INSTALLATION & MAINTENANCE Keyset Installation 7.3 Ensure that the station loop resistance test has been performed before installing the keysets. 7.4 Install all keysets as follows: (1) (2) Before mounting the modular jack assembly and connecting the keyset, measure the voltage on the BLACK (+28) terminal of the modular jack assembly with respect to the YELLOW (GND) terminal. (The “common” probe of the voltmeter is placed on the...
Page 53
INTER-TEL PRACTICES GLX-PLUS INSTALLATION & MAINTENANCE INSTALLATION Issue 2, June 1993 n. Press and release the hookswitch. The speak- erphone microphone is connected to the handset receiver. (Display keyseta show SPKRPHN MIC TEST.) o. While speaking into the speakerphone microphone (or rubbing a finger over the opening to the microphone), determine that the sound is being broadcast over the handset receiver. p. Place the handset back in its cradle. The key- set rings momentarily and it...
Page 54
INSTALIATION INTER-TEL PRACTICES Issue 2, June 1993 GLX-PLUS INSTALLATION & MAINTENANCE Wall Mounting Keysets 7.8 To mount the keyset on a wall (refer to Figure 3-16 below): (4) (1) Remove the keyset baseplate and set the keyset aside. (2) Rotate the baseplate so that the mounting holes (5) are at the top. Position the plate in the desired location on the wall. (6) (3) Mark the location of the keyset mounting holes on the wall. Set the baseplate aside. Drive a #8 pan-head screw (or proper...
Page 55
INTER-TEL PRACTICES GLX-PLUS INSTALLATION & MAINTENANCE INSTALLATION Issue 2, June 1993 Optional Data Port Module For GLX-Plus Keysets 7.9 GLX-Plus Keysets may be equipped with optional Data Port Modules (part number 828.1094). The Data Port Module contains a four-conductor modular jack that can be used to connect either a data device (such as a personal computer with a direct-connect modem) or an LRA and an external signaling device (such as a loud bell, horn, flashing light, etc.) to the...
Page 56
INSTALLATION Issue 2, June 1993 INTER-TEL PRACTICES GLX-PLUS INSTALLATION & MAINTENANCE FIGURE 3-17. GLX-PLUS KEYSET DATA PORT MODULE INSTALLATION SE-ITING FOR SElTlNG DATA DEVICE FOR LRA JUMPER STRAPS MODULAR JACK YAIA run 1 MODULE TO SHORTING PLUG LOCATION (on keyset control board) Page 3-28
Page 57
INTER-TEL PRACTICES GLX-PLUS INSTALLYIION & MAINTENANCE INSTALLATION Issue 2, June 1993 7.14 To connect a Loud Ringing Adapter (LRA): The optional Data Port Module on GLX-Plus Keysets and the ancillary jack (labeled DATA) on Executive Keysets can be used to connect external signaling equip- ment such as loud bells, horns, flashing lights, etc. to a keyset. This application is useful in areas where the nor- mal ring tone of the keyset cannot be heard, such as warehouses and loading docks. The...
Page 58
INSTALLATION Issue 2, June 1993 INTER-TEL PRACTICES GLX-PLUS INSTACLATION & MAINTENANCE GLX-Plus Keyset Battery Back-Up 7.17 GLX-Plus Keysets can be equipped with option- al date, time, and volume setting battery back-up using a battery connection kit (828.1239) and a customer-pro- vided 9V battery. (Refer to page 2-11 for more informa- tion.) (5) (1) Unpack the battery connection kit. There should (6) be a battery clip, a two-wire battery strap, and two small pieces of double-sided foam tape...
Page 59
INTER-TEL PRACTICES GLX-PLUS INSTALLATION & MAINTENANCE INSTALLATION Issue 2, June 1993 B. SINGLE-LINE SET INSTALLATION 7.18 Up to two industry-standard, AC-ringing, DTMF single-line sets may be connected to the KSU if the op- tional Accessory Port Module is installed. 7.19 To install a single-line set: (1) Before connecting a single-line set to the system, measure the voltage on the RED terminal of the modular jack assembly with respect to the GREEN terminal. (The common probe of the...
Page 60
INSTALLATION Issue 2, June 1993 INTER-TEL PRACTICES GLX-PLUS INSTALLATION & MAINTENANCE FIGURE 3-20. CONNECT THE EXTERNAL, EQUIPMENT rKSU E-PAGE, l/8 IN. PAGING AMPLIFIER mm MINI-PHONE PLUG am- ,. ’ 11 1 1% PHONd PLUG MUSIC RCA-TYPE v L MUSIC SOURCE Page 3-32