Home > Honeywell > Control panel > Honeywell Galaxy 2 User Manual

Honeywell Galaxy 2 User Manual

Here you can view all the pages of manual Honeywell Galaxy 2 User Manual. The Honeywell manuals for Control panel are available online for free. You can easily download all the documents as PDF.

Page 61

53
Galaxy 2 Series Installation Manual
Option 23 - System Version
This option shows the panel type and software version.
Option 24 - Print
NOTE:A serial printer must be connected to the program header on the Galaxy 2 Series PCB.
This option allows the user to print out the event log.
NOTE:The system programming can only be printed by an engineer in menu option 57.
  A master code can also print out the users. There are four sub-menus:
1 = Codes
Only Master codes and engineers can print the information...

Page 62

54
Galaxy 2 Series Installation Manual
Menu 30 - Test Options
Option 31 - Walk Test
Menu option 31 allows a selection of zones or a single zone to be put on walk test.
NOTE:Zones programmed with the following functions remain active during the walk test:
24 hours, PA, PA silent, Fire, Tamper, Batt Fail, AC Fail, Assistance, Bell Fail.
Menu Option 31 has two settings:
1 = Test All Zones
This option initiates a walk test that includes all zones that have the omit attribute enabled (refer to option 52 =...

Page 63

55
Galaxy 2 Series Installation Manual
Table 17. User Attributes
1 = Pin
The PIN identifies each user to the Galaxy 2 Series panel and permits the user to operate the system. This
option allows a PIN to be assigned to a user or an existing PIN to be modified. The PIN must be a four, five
or six digit number that is unique to the system. If a duplicate PIN is assigned, the message DUPLICATE
ENTRY is displayed; the PIN is not assigned to the user. As each digit is entered it appears on the lower line
of...

Page 64

56
Galaxy 2 Series Installation Manual
* 0 = No Access
1  = Access sub-menu 1 only
2  = Access sub-menu 1 & 2
Yes* Only if set by engineer
The engineer always has access to all menu options. However, in the codes menu the engineer can only edit
the engineer’s PIN code.Table 18. User Types
Modify Options (cont’d)
2 = Type
This attribute shows the type of user and the level of access for each. There are four sub-options:
0 = Cleaner (L2)
1 = Users (L2)
2 = Manager (L2)
3 = Master (L3)
User Types
A user...

Page 65

57
Galaxy 2 Series Installation Manual
3 = Groups
This attribute determines the system groups that the user has access to and operational control over. This
attribute is only available when the groups option is enabled, see Option 63.1.
Access to the common group is not required as this arms and disarms automatically.
A modifier can be assigned to the groups. If the * is selected and displayed , then the user will have a choice
at the point of setting and unsetting, of which groups of their assigned...

Page 66

58
Galaxy 2 Series Installation Manual
Adding Keytags or Cards - Mk7 485 Keyprox only
1. Enter menu 42.1 = Users.Users.
2. Select a user.
3. Select option 6 = Prox Tags.
4. Press A & 1 together to self-learn keytag/card on to system.
NOTE: When pressing A & 1, make sure keytag or card is kept away from prox symbol or else the number
will be misread.
5. Hold card/keytag in front of prox symbol to add it in.
6. The number should be displayed.
7. Wait for double beep then remove keytag/card.
8. Press enter...

Page 67

59
Galaxy 2 Series Installation Manual
Option 44 - Mobile Nos
The Galaxy 2 Series can send SMS messages to users on up to three separate phone numbers to alert them of
system events.
This option allows users to set up or alter the mobile phone numbers and the types of messages sent. There
are three sub-options, one for each phone:
1 = Call 1
2 = Call 2
3 = Call 3
Each of these options has a further sub-menu as follows:
1 = Mobile Number
The mobile number can be up to 20 digits long.
2 = Message Type
This...

Page 68

60
Galaxy 2 Series Installation Manual
Option 47 - Remote Access
1 = Service
This option allows a user to initiate a call to the remote service centre or authorise a call in from the remote
servicing centre. On entering the menu, the user can select which communication device is used.
1 = Telecoms
5 = GSM (2–44+ only)
Upon selecting the device, the user can select which communication mode is used.
0 = Direct Access
This enables a five minute window where the panel will accept an incoming call for the...

Page 69

61
Galaxy 2 Series Installation Manual
Menu 50 - Engineer 1 Options
Option 51 - Parameters
This option allows the engineer to modify the settings for the system functions. Options can be selected using
the A or B keys or by entering the two digit parameter number and pressing the ent key.  The selected options
can then be programmed by typing the new value directly or by using the A key to increase or the B key to
decrease the values assigned to the parameter; pressing the ent key accepts the new value...

Page 70

62
Galaxy 2 Series Installation Manual
Table 19. System Parameters
51 - Parameters (cont’d)
Parameter Values Defaults
01=Bell Time 01-30 minutes15 minutes
02=Bell Delay 0=Off.  1=On - 10 min. 0 = Off
04=Exit Time 00 - 99 Seconds. 00=Infinite time/final contact. 30
05=Entry Time 00 - 99 seconds.30
06=Part set exit 0=Silent  1=Keypad only  2=Keypad & Speaker 1 = Keypad
07=Intruder Resets 0=User 1=Remote1 = Remote
08=Exit Terminate 0=No 1=Full set only  2=Full and part set only  3=All set modes 0 = No...