Galaxy 2 Series Installation Manual
SECTION 12:  PRINTER CONNECTION
The Galaxy 2 Series can print system detail directly to a serial printer. In order to do this a printer lead is
required (part number A225) to connect between the program header on the Galaxy 2 Series PCB and the
printer.
The printer must have the following settings:
• Baud Rate:1200
• Parity:None
• Stop Bits: 2
• Data Bits: 8
• Start Bits: 1
When this has been set up, system information can be printed as per menu options 24 and 57....

Page 112

104
Galaxy 2 Series Installation Manual
SECTION 13:  BELL-BOX CONNECTIONS
The terminal connections for various bell-box models are shown below:
Lyntech Ltd. - 120 LED/120 lexon
Elmdene Rapier 3000, 4000, 5000, 6000; Prima 100, 200,300,400,500 600; Starlight 020
CQR Security - Sigma, Cequera, Plus and Ultima
Ventcroft Security - Vision, Classic, and Spirit
Flashguard - Xtra
Intellisense AG3
NOTE:Where 2 connections are specified for the bell box connection a 0 ohm link must be made between
the 2 terminals...

Page 113

105
Galaxy 2 Series Installation Manual
SECTION 14:  EVENT LOG LIST
EVENTDESCRIPTION
+ AC AC zone activated
- AC AC zone closed
+ AC> AC zone signalled
-  AC> AC zone closed signalled
+  CU AC Panel Mains fault
-  CU AC Panel Mains reinstated
+  CU AC> Mains loss signalled
-  CU AC> Mains restored signalled
+ PSU ACRemote PSU Mains fault
- PSU ACRemote PSU mains reinstated
+PSU AC>Remote PSU Mains fault signalled
- PSU AC>Remote PSU Mains reinstated
+ ASSISTAssistance zone activation
- ASSISTAssistance...

Page 114

106
Galaxy 2 Series Installation ManualEvent Log List (cont’d)
EVENTDESCRIPTION
+  PA Panic zone activated
-  PA Panic zone closed
+  PA> Panic zone signalled
-  PA> Panic zone closed signalled
PA RESET PA Reset
+  PA  SIL Silent Panic zone activated
-  PA  SIL Silent Panic zone closed
+ PASIL>Silent Panic zone activation signalled
- PASIL>Silent Panic zone closed signalled
+ RF BATT Wireless detector battery low
- RF BATT Wireless detector battery low cleared
+ RF BATT> Wireless detector battery fault...

Page 115

107
Galaxy 2 Series Installation Manual
EVENTDESCRIPTION
RESETSystem reset
SOAK TSTZone soak test activation
+ OVERRDE Override of system faults
TIM/DATE Time/Date adjusted
- OMITZone unomitted
UNSET System unset
WALKTST- Walk test ended
WALKTST+ Walk test started
WDOG RST System reboot
+ OMITZone omitted
ZONE TST Zone tested
POWER ONPanel Power On
RESTARTPanel restarted
REARMRearm of system has occured
+ 24 HR 24 HR zone activated
-  24  HR 24 HR zone closed
+ INT>Intruder signalled
- INT>Intruder...

Page 116

108
Galaxy 2 Series Installation ManualSpecifications
SECTION 15:  SPECIFICATIONS
Table 29. Panel Specifications
Panel Specifications2-44+ 2-20
Physical
Plastic Box-3 mm polycarb
( w it h ma ins  t r a ns fo r me r  a nd  P C B ins t a lle d )Width: 300 mm
Height: 250 mm
Depth: 100 mm
We ight : 1 . 7  k gWidth: 300 mm
Height: 250 mm
Depth: 100 mm
Weight: 1.7 kg
Metal Box-1.2 mm steel
( w it h ma ins  t r a ns fo r me r  a nd  P C B ins t a lle d )Width: 370 mm
Height: 320 mm
Depth: 85 mm
We ight : 4 . 5...

Page 117

109
Galaxy 2 Series Installation ManualSpecifications (cont’d)
Table 30. Peripheral Current Consumption
PERIPHERAL QUIESCENT
CURRENT (mA)MAXIMUM ALARM
CURRENT (mA)
Mk 7 Keyprox 90 130
RIO 40
P ower RIO/P ower Uni t 100
RF P ortal 55
6160 Keyprox 40 200
5800 RF Receiver 60
ECP Expander 25
GSM Module 10 

Page 118

110
Galaxy 2 Series Installation Manual
SECTION 16:  COMPLIANCE AND APPROVALS
The Galaxy 2 Series is compliant with the relevant parts of the following standards:
• 99/05/ECR&TTE Directive
• EN50130-5:1998Alarm systems. Environmental test methods
It is a condition of the product’s approval that the installation complies with the following:
EN50131 Compliance
This product is suitable for use in systems designed to comply with PD6662:2004 and EN50131-1:2004.
Security  Grade - 2
Environmental Class - II...

Page 119

111
Galaxy 2 Series Installation Manual
HONEYWELL SECURITY LIMITED WARRANTY
Honeywell Security, and its divisions, subsidiaries and affiliates (“Seller”), 165 Eileen Way, Syosset, New
York, 11791, warrants its products to be in conformance with its own plans and specifications and to be free
from defects in materials and workmanship under normal use and service for 24 months from the date stamp
control on the product.  Seller’s obligation shall be limited to repairing or replacing, at its option, free of...

Page 120

112
Galaxy 2 Series Installation Manual 
Start reading Honeywell Galaxy 2 User Manual

Related Manuals for Honeywell Galaxy 2 User Manual

All Honeywell manuals