Page 111
103 Galaxy 2 Series Installation Manual SECTION 12: PRINTER CONNECTION The Galaxy 2 Series can print system detail directly to a serial printer. In order to do this a printer lead is required (part number A225) to connect between the program header on the Galaxy 2 Series PCB and the printer. The printer must have the following settings: • Baud Rate:1200 • Parity:None • Stop Bits: 2 • Data Bits: 8 • Start Bits: 1 When this has been set up, system information can be printed as per menu options 24 and 57....
Page 112
104 Galaxy 2 Series Installation Manual SECTION 13: BELL-BOX CONNECTIONS The terminal connections for various bell-box models are shown below: Lyntech Ltd. - 120 LED/120 lexon Elmdene Rapier 3000, 4000, 5000, 6000; Prima 100, 200,300,400,500 600; Starlight 020 CQR Security - Sigma, Cequera, Plus and Ultima Ventcroft Security - Vision, Classic, and Spirit Flashguard - Xtra Intellisense AG3 NOTE:Where 2 connections are specified for the bell box connection a 0 ohm link must be made between the 2 terminals...
Page 113
105 Galaxy 2 Series Installation Manual SECTION 14: EVENT LOG LIST EVENTDESCRIPTION + AC AC zone activated - AC AC zone closed + AC> AC zone signalled - AC> AC zone closed signalled + CU AC Panel Mains fault - CU AC Panel Mains reinstated + CU AC> Mains loss signalled - CU AC> Mains restored signalled + PSU ACRemote PSU Mains fault - PSU ACRemote PSU mains reinstated +PSU AC>Remote PSU Mains fault signalled - PSU AC>Remote PSU Mains reinstated + ASSISTAssistance zone activation - ASSISTAssistance...
Page 114
106 Galaxy 2 Series Installation ManualEvent Log List (cont’d) EVENTDESCRIPTION + PA Panic zone activated - PA Panic zone closed + PA> Panic zone signalled - PA> Panic zone closed signalled PA RESET PA Reset + PA SIL Silent Panic zone activated - PA SIL Silent Panic zone closed + PASIL>Silent Panic zone activation signalled - PASIL>Silent Panic zone closed signalled + RF BATT Wireless detector battery low - RF BATT Wireless detector battery low cleared + RF BATT> Wireless detector battery fault...
Page 115
107 Galaxy 2 Series Installation Manual EVENTDESCRIPTION RESETSystem reset SOAK TSTZone soak test activation + OVERRDE Override of system faults TIM/DATE Time/Date adjusted - OMITZone unomitted UNSET System unset WALKTST- Walk test ended WALKTST+ Walk test started WDOG RST System reboot + OMITZone omitted ZONE TST Zone tested POWER ONPanel Power On RESTARTPanel restarted REARMRearm of system has occured + 24 HR 24 HR zone activated - 24 HR 24 HR zone closed + INT>Intruder signalled - INT>Intruder...
Page 116
108 Galaxy 2 Series Installation ManualSpecifications SECTION 15: SPECIFICATIONS Table 29. Panel Specifications Panel Specifications2-44+ 2-20 Physical Plastic Box-3 mm polycarb ( w it h ma ins t r a ns fo r me r a nd P C B ins t a lle d )Width: 300 mm Height: 250 mm Depth: 100 mm We ight : 1 . 7 k gWidth: 300 mm Height: 250 mm Depth: 100 mm Weight: 1.7 kg Metal Box-1.2 mm steel ( w it h ma ins t r a ns fo r me r a nd P C B ins t a lle d )Width: 370 mm Height: 320 mm Depth: 85 mm We ight : 4 . 5...
Page 117
109 Galaxy 2 Series Installation ManualSpecifications (cont’d) Table 30. Peripheral Current Consumption PERIPHERAL QUIESCENT CURRENT (mA)MAXIMUM ALARM CURRENT (mA) Mk 7 Keyprox 90 130 RIO 40 P ower RIO/P ower Uni t 100 RF P ortal 55 6160 Keyprox 40 200 5800 RF Receiver 60 ECP Expander 25 GSM Module 10
Page 118
110 Galaxy 2 Series Installation Manual SECTION 16: COMPLIANCE AND APPROVALS The Galaxy 2 Series is compliant with the relevant parts of the following standards: • 99/05/ECR&TTE Directive • EN50130-5:1998Alarm systems. Environmental test methods It is a condition of the product’s approval that the installation complies with the following: EN50131 Compliance This product is suitable for use in systems designed to comply with PD6662:2004 and EN50131-1:2004. Security Grade - 2 Environmental Class - II...
Page 119
111 Galaxy 2 Series Installation Manual HONEYWELL SECURITY LIMITED WARRANTY Honeywell Security, and its divisions, subsidiaries and affiliates (“Seller”), 165 Eileen Way, Syosset, New York, 11791, warrants its products to be in conformance with its own plans and specifications and to be free from defects in materials and workmanship under normal use and service for 24 months from the date stamp control on the product. Seller’s obligation shall be limited to repairing or replacing, at its option, free of...