Page 71
63 Galaxy 2 Series Installation Manual 01 = Bell Time This is the amount of time that the sounders/bells activate after an alarm condition has occured. The duration of the output is programmable within the range 01-30 minutes; the default is 15. 02 = Bell Delay This parameter, when set to On, delays the operation of the bell for 10 minutes following an intruder alarm. 04 = Exit time This is the amount of time that the user has to exit the premises after initiating a Full Set procedure. The Exit Time is...
Page 72
64 Galaxy 2 Series Installation Manual 07 = Intruder Resets This parameter dictates what type of reset is required for a signalled intruder alarm. There are two settings: 0. User This setting allows any user programmed with the following user types: user, manager, master, to reset a full intruder alarm. 1. Remote (default) This setting requires an engineer or remote reset for a signalled intruder alarm. If this option is selected on a system where confirmed alarms are used, then the reset level required...
Page 73
65 Galaxy 2 Series Installation Manual 12 = Banner This parameter has three settings: 1. Top Line 2. Bottom Line 3. Show on Set 0 = Off (Blank display when Set) 1 = On (Display normal banner when set) The Day Mode Banner display on keypads can be altered. The top and bottom row can be edited separately with descriptors of up to 16 characters. Each number key on the keypad is assigned several characters that are accessed by pressing the key repeatedly until the desired character appears on the screen....
Page 74
66 Galaxy 2 Series Installation Manual Keypad tamper lockout is indicated on the keypad display. After 20 attempts, a tamper is logged and an event is signalled. When option 2 or 3 are selected the same rules apply to wireless fobs and prox tags. 15 = SPK Mode This function selects whether the LS (loudspeaker) terminal acts as a speaker driver or a normal switched output. There are two settings. 0. Switch DC 1. SPK Driver NOTE:Never connect a speaker to this terminal when the mode is set to Switch DC. 16...
Page 75
67 Galaxy 2 Series Installation Manual 3. RF Jam This option selects whether or not the system can be set while there is an RF Jam (interference condition) present. 4. TEL Line Fault When set to on a line fault can be detected by the panel. A line fail prevents setting. 19 = Part Bells This option determines whether the External Bell and Strobe outputs activate during an alarm condition when the system is Part Set. 0.No 1. Yes (default) NOTE:Internal sounders always sound. 20 = Night Bells This option...
Page 76
68 Galaxy 2 Series Installation Manual 24 = Entry Deviation This parameter has two settings: 0.No 1. Yes (default) If set to 0 (Entry Deviation not permitted), deviation from an entry route during entry or supplementary entry periods will result in a Full Alarm Condition. An entry route is defined as zones programmed as 01 (final) and 02 (exit). Entry Deviation permitted (1) means that external bells/communications/triggers will be withheld until the entry time expires. Entering a valid code before a...
Page 77
69 Galaxy 2 Series Installation Manual 2. EOL Resistor This selects the resistor value for the end of line (EOL) resistor used in EOL double balance zone configura- tions. Normally this should be 1000 ohms. The value entered is in hundreds of ohms, 01 = 100 ohms, 99 = 9900 ohms. 3. Contact Res As for EOL Resistor but for Contact resistor. 47 = Set confirm This parameter gives an external indication when the system has set. There are three options: 0. Off 1. Strobe (flashes for two seconds) 2. Strobe &...
Page 78
70 Galaxy 2 Series Installation Manual 6.RF Check The RF Check is a means of warning the user that the system is unable to determine the status of the detector. There are two options: 0 = No This option disables the checking of the RF Stop Set (see Section 8, RF Stop Set). 1 = Yes This option enables the checking of the RF stop set. 55 = DD243 The options of this parameter allow the confirmed alarm reporting operation to be modified to tailor the system to requirements of DD243: 2002, depending on the...
Page 79
71 Galaxy 2 Series Installation Manual 2 = Never Unset The keypad can never unset the system. Unsetting can only be performed by a keyfob, proximity tag or card. NOTE:If the panel becomes locked by accidental selection of this option, the panel can be force unset by the following procedure: (a) Remove all power from the system. (b) Open the panel lid tamper. (c) Re-apply power. The system will power up unset in a tamper condition. 4. Restart time This option has two settings: 0 = No (default) 1 = If 1 st...
Page 80
72 Galaxy 2 Series Installation Manual 8. Exit ZN conf. 0 = Before Entry (default) 1 = Except Entry 9. Entry clears conf. This options selects whether a single (unconfirmed) alarm activation is remembered for the purposes of confir- mation, after an entry door is open. This option has two settings: 0 = Reset Count In this case, the confirmed alarm counter is reset to 0 as soon as an entry door is opened. 1 = Keep Count (default) In this case, the confirmed alarm counter is maintained. If there is one...