103 Galaxy 2 Series Installation Manual SECTION 12: PRINTER CONNECTION The Galaxy 2 Series can print system detail directly to a serial printer. In order to do this a printer lead is required (part number A225) to connect between the program header on the Galaxy 2 Series PCB and the printer. The printer must have the following settings: • Baud Rate:1200 • Parity:None • Stop Bits: 2 • Data Bits: 8 • Start Bits: 1 When this has been set up, system information can be printed as per menu options 24 and 57. Printer Connection
104 Galaxy 2 Series Installation Manual SECTION 13: BELL-BOX CONNECTIONS The terminal connections for various bell-box models are shown below: Lyntech Ltd. - 120 LED/120 lexon Elmdene Rapier 3000, 4000, 5000, 6000; Prima 100, 200,300,400,500 600; Starlight 020 CQR Security - Sigma, Cequera, Plus and Ultima Ventcroft Security - Vision, Classic, and Spirit Flashguard - Xtra Intellisense AG3 NOTE:Where 2 connections are specified for the bell box connection a 0 ohm link must be made between the 2 terminals on the bell box PCB. Bell-Box Connections 2 Series Terminals BELL + 12V 0V T Bell box Terminals +H -R -H RTN -ST 2 Series Terminals BELL + 12V 0V T Bell box TerminalsHOLD OFF +VESIREN TRIGHOLD OFF -VEA/T RET SIGSTROBE TRIG 2 Series Terminals BELL + 12V 0V T Bell box TerminalsHOLD OFF +VE, STB +VETRIG -HOLD OFF -VERTN S TB - 2 Series Terminals BELL + 12V 0V T Bell box TerminalsSUPPLY + STROBE +TRIGGER TA MP OUT S UP PLY - STROB - 2 Series Terminals BELL + 12V 0V T Bell box Terminals V + S - V - TR ST - 2 Series Terminals BELL + 12V 0V T Bell box Terminals HOLD + TRG HOLD- TAMP R STRB
105 Galaxy 2 Series Installation Manual SECTION 14: EVENT LOG LIST EVENTDESCRIPTION + AC AC zone activated - AC AC zone closed + AC> AC zone signalled - AC> AC zone closed signalled + CU AC Panel Mains fault - CU AC Panel Mains reinstated + CU AC> Mains loss signalled - CU AC> Mains restored signalled + PSU ACRemote PSU Mains fault - PSU ACRemote PSU mains reinstated +PSU AC>Remote PSU Mains fault signalled - PSU AC>Remote PSU Mains reinstated + ASSISTAssistance zone activation - ASSISTAssistance zone closed + AUXFUSEAux fuse blown - AUXFUSEPanel Aux fuse fault cleared + BAT MIS Panel Battery disconnected - BAT MIS Panel Battery reconnected + BATTERYRemote PSU battery low (zone) - BATTERYRemote PSU battery low cleared (zone) + CU BATT Control Unit battery fail - CU BATT Control Unit battery fault restored + BELFUSEBell fuse Blown - BELFUSEBell fuse fault cleared + BELLFLT Bell fault zone activated - BELLFLTBell fault cleared + DURESSDuress Condition activated - DURESSDuress condition cleared +ENG CDE Engineer Mode accessed non EN50 + FIREFire zone activated - FIREFire zone closed + FIRE>Fire zone signalled - FIRE>Fire zone closed signalled + FOB BAT Fob battery low - FOB BATFob battery fault cleared + INTRUIntruder zone activated - INTRUIntruder zone closed + JAM Jam condition detected - JAM Jam condition cleared + JAM>Jam condition signalled + LINKLink zone activated - LINKLink zone closed + PSU BATSmart PSU battery low - PSU BAT Smart PSU battery Low cleared + PSU FUSESmart PSU fuse blown - PSU FUSESmart PSU fuse fault cleared Event Log List
106 Galaxy 2 Series Installation ManualEvent Log List (cont’d) EVENTDESCRIPTION + PA Panic zone activated - PA Panic zone closed + PA> Panic zone signalled - PA> Panic zone closed signalled PA RESET PA Reset + PA SIL Silent Panic zone activated - PA SIL Silent Panic zone closed + PASIL>Silent Panic zone activation signalled - PASIL>Silent Panic zone closed signalled + RF BATT Wireless detector battery low - RF BATT Wireless detector battery low cleared + RF BATT> Wireless detector battery fault signalled + RFCHOV RF check override - RFCHOV RF check override restore + RF OVRR RF low battery override - RF OVRR RF low battery override restore + STU FLTExternal Comms Fault - STU FLTExternal Comms Fault cleared + SUPERVDetector supervision fault - SUPERVDetector Supervision cleared + SV OVER RF Supervision fail override - SV OVER RF Supervision fail override restore + TAMPER Tamper condition activated - TAMPER Tamper condition cleared +USR TMP Tamper due to wrong code -USR TMP Tamper due to wrong code cleared CANCELAlarm cancelled by user AUTO TSTAutomatic comms test CODE CHG User codes edited COM FAILSignalling failed COM RSTSignalling restored CONFIRMConfirmed alarm activation DEFAULTS Panel defaults loaded COMM TSTEngineer signalling test + REMOTERemote servicing started -REMOTE Remote servicing ended EASY SETEasy set by user FBAT ACK Fob low battery acknowledged FULL SET System full set FULL TSTFull test activated LOCKOUT Lockout due to wrong codes LINE FLTPhone line fault LINE RST Phone line restored + MISSINGSystem module missing - MISSINGSystem module reinstated NGHT SET System Night set - OVERRDEFault override cancelled PART SET System Part set + PROGRAMProgram mode enterd - PROGRAMProgram mode exited
107 Galaxy 2 Series Installation Manual EVENTDESCRIPTION RESETSystem reset SOAK TSTZone soak test activation + OVERRDE Override of system faults TIM/DATE Time/Date adjusted - OMITZone unomitted UNSET System unset WALKTST- Walk test ended WALKTST+ Walk test started WDOG RST System reboot + OMITZone omitted ZONE TST Zone tested POWER ONPanel Power On RESTARTPanel restarted REARMRearm of system has occured + 24 HR 24 HR zone activated - 24 HR 24 HR zone closed + INT>Intruder signalled - INT>Intruder restore signalled + ENT T/OEntry Timeout alarm - ENT T/OEntry Timeout alarm cancelled + ENT T/O>Entry Timeout alarm signalled - ENT T/O>Entry Timeout alarm cancel signalled TEST END Event Log List (cont’d)
108 Galaxy 2 Series Installation ManualSpecifications SECTION 15: SPECIFICATIONS Table 29. Panel Specifications Panel Specifications2-44+ 2-20 Physical Plastic Box-3 mm polycarb ( w it h ma ins t r a ns fo r me r a nd P C B ins t a lle d )Width: 300 mm Height: 250 mm Depth: 100 mm We ight : 1 . 7 k gWidth: 300 mm Height: 250 mm Depth: 100 mm Weight: 1.7 kg Metal Box-1.2 mm steel ( w it h ma ins t r a ns fo r me r a nd P C B ins t a lle d )Width: 370 mm Height: 320 mm Depth: 85 mm We ight : 4 . 5 k gWidth: 400 mm Height: 255 mm Depth: 115 mm Weight: 4.2 kg Electrical P a ne l C urre nt C o nsump tio n PSU Type Mains Input Back-up Battery P S U M a x t o t a l lo a d Grade 2 Rating Ma x c o ntinuo us rip p le vo lta ge Individual 12 V outputs: Be ll+ 1 2 V Both Aux+combined Trigger Header+12V S witc he d Outputs : Trigger Header Outputs Be ll Tr igge r 1 0 0 3 Strobe Trigger 1004 Trig Output 1001 Spe ake r Output: Speaker output 1002 Fus e s : Mains Battery (F1) Aux (F 2 ) Be ll ( F 3 )120 mA (max) A 230 V ac (+10% -15%) Up to 7.2Ahr 12 V Sealed Lead-Acid (plastic encl.) Up to 17Ahr 12 V Sealed Lead-Acid (metal encl.) 1.4 A (nominal temp. and mains supply) 1 A 0.5 V at max. load 500 mA max 500 mA max 100 mA max Can sink 30 mA each Can sink 500 mA max Can sink 500 mA max Can sink 300 mA each 8 to 32 ohms or 100 mA in switched DC mode 500 mA, 20 mm anti-surge (IEC 127) 1 A, 20 mm anti-surge 500 mA, 20 mm anti-surge 500 mA, 20 mm anti-surge120 mA (max) A 230 V ac (+10% -15%) Up to 7.2Ahr 12 V Sealed Lead-Acid (plastic encl.) Up to 12Ahr 12 V Sealed Lead-Acid (metal encl.) 1.0 A (nominal temp. and mains supply) 600 mA 0.5 V at max. load 500 mA max 500 mA max 1 0 0 mA ma x C a n sink 3 0 mA e a c h C a n sink 5 0 0 mA ma x C a n sink 5 0 0 mA ma x Can sink 300 mA each 8 to 32 ohms or 100 mA in switched DC mode 200 mA-20 mm anti-surge (IEC 127) 1 A, 2 0 mm a nti- surge 500 mA, 20 mm anti-surge 500 mA, 20 mm anti-surge
109 Galaxy 2 Series Installation ManualSpecifications (cont’d) Table 30. Peripheral Current Consumption PERIPHERAL QUIESCENT CURRENT (mA)MAXIMUM ALARM CURRENT (mA) Mk 7 Keyprox 90 130 RIO 40 P ower RIO/P ower Uni t 100 RF P ortal 55 6160 Keyprox 40 200 5800 RF Receiver 60 ECP Expander 25 GSM Module 10
110 Galaxy 2 Series Installation Manual SECTION 16: COMPLIANCE AND APPROVALS The Galaxy 2 Series is compliant with the relevant parts of the following standards: • 99/05/ECR&TTE Directive • EN50130-5:1998Alarm systems. Environmental test methods It is a condition of the product’s approval that the installation complies with the following: EN50131 Compliance This product is suitable for use in systems designed to comply with PD6662:2004 and EN50131-1:2004. Security Grade - 2 Environmental Class - II Alarm Transmission System - 2 (options A, B, C & X) Power Supply Type - A This product is also suitable for use in alarm systems designed to comply with EN50131-1:1997. Security Grade - 2 Environmental Class - II Alarm Transmission System - D2, T2, A2, I0, S0 Power Supply Type - A Public Switched Telephone Network (PSTN) Approval The equipment has been approved to Council Decision 98/482/EC for Pan -European single terminal connec- tion to the Public Switched Telephone Network (PSTN). However due to differences between the individual PSTNs provided in different countries the approval does not, of itself, give an unconditional assurance of successful operation on every PSTN network termination point. In the event of problems contact the equipment supplier in the first instance. The Galaxy 2 Series is designed to interwork with the following networks: AustriaFranceItalyNorwayUnited Kingdom BelgiumGreeceLiechtensteinPortugal Denmark IcelandLuxembourgSpain FinlandIrelandThe Netherlands Sweden NOTE:Contact the equipment supplier before using the Galaxy 2 Series on any network not listed. Approvals
111 Galaxy 2 Series Installation Manual HONEYWELL SECURITY LIMITED WARRANTY Honeywell Security, and its divisions, subsidiaries and affiliates (“Seller”), 165 Eileen Way, Syosset, New York, 11791, warrants its products to be in conformance with its own plans and specifications and to be free from defects in materials and workmanship under normal use and service for 24 months from the date stamp control on the product. Seller’s obligation shall be limited to repairing or replacing, at its option, free of charge for materials or labour, any product that is proved not in compliance with Seller’s specifications or proves defective in materials or workmanship under normal use and service. Seller shall have no obligation under this Limited Warranty or otherwise if the product is altered or improperly repaired or serviced by anyone other than Honeywell factory service. For warranty service, return product transportation prepaid to: Honeywell Security, 6 Aston Fields Road, Whitehouse Industrial Estate, Runcorn, Cheshire WA7 3DL THERE ARE NO WARRANTIES, EXPRESS OR IMPLIED, OF MERCHANTABILITY, OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE, WHICH EXTEND BEYOND THE DESCRIP- TION ON THE FACE HERE OF. IN NO CASE SHALL SELLER BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY, EXPRESS OR IMPLIED, OR UPON ANY OTHER BASIS OF LIABILITY WHATSO- EVER, EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER’S OWN NEGLIGENCE OR FAULT. Seller does not represent that the products it sells may not be compromised or circumvented; that the prod- ucts will prevent any personal injury or property loss by burglary, robbery, fire or otherwise; or that the prod- ucts will in all cases provide adequate warning or protection. Customer understands that a properly installed and maintained alarm may only reduce the risk of a burglary, robbery, fire or other events occurring without providing an alarm, but it is not insurance or a guarantee that such will not occur or that there will be no per- sonal injury or property loss as a result. CONSEQUENTLY, SELLER SHALL HAVE NO LIABILITY FOR ANY PERSONAL INJURY, PROP- ERTY DAMAGE OR OTHER LOSS BASED ON A CLAIM THE PRODUCT FAILED TO GIVE WARNING. HOWEVER, IF SELLER IS HELD LIABLE, WHETHER DIRECTLY OR INDIRECTLY, FOR ANY LOSS OR DAMAGE ARISING UNDER THIS LIMITED WARRANTY OR OTHERWISE, REGARDLESS OF CAUSE OR ORIGIN, SELLER’S MAXIMUM LIABILITY SHALL NOT IN ANY CASE EXCEED THE PURCHASE PRICE OF THE PRODUCT, WHICH SHALL BE THE COMPLETE AND EXCLUSIVE REMEDY AGAINST SELLER. This warranty replaces any previous warranties and is the only warranty made by Seller on this product. No increase or alteration, written or verbal, of the obligations of this Limited Warranty is authorized. Honeywell Security 2 Redwood Crescent Peel Park Campus East Kilbride G74 5PA UK Warranty