    Galaxy 2 Series Installation Manual
    SECTION 12:  PRINTER CONNECTION
    The Galaxy 2 Series can print system detail directly to a serial printer. In order to do this a printer lead is
    required (part number A225) to connect between the program header on the Galaxy 2 Series PCB and the
    printer.
    The printer must have the following settings:
    • Baud Rate:1200
    • Parity:None
    • Stop Bits: 2
    • Data Bits: 8
    • Start Bits: 1
    When this has been set up, system information can be printed as per menu options 24 and 57.
    Printer Connection 
    						
    							104
    Galaxy 2 Series Installation Manual
    SECTION 13:  BELL-BOX CONNECTIONS
    The terminal connections for various bell-box models are shown below:
    Lyntech Ltd. - 120 LED/120 lexon
    Elmdene Rapier 3000, 4000, 5000, 6000; Prima 100, 200,300,400,500 600; Starlight 020
    CQR Security - Sigma, Cequera, Plus and Ultima
    Ventcroft Security - Vision, Classic, and Spirit
    Flashguard - Xtra
    Intellisense AG3
    NOTE:Where 2 connections are specified for the bell box connection a 0 ohm link must be made between
    the 2 terminals on the bell box PCB.
    Bell-Box Connections
    2 Series Terminals BELL + 12V 0V T
    Bell box Terminals +H -R -H RTN -ST
    2 Series Terminals BELL +  12V 0V T
    Bell box TerminalsHOLD  OFF
    +VESIREN
    TRIGHOLD  OFF
    -VEA/T RET
    SIGSTROBE
    TRIG
    2 Series Terminals BELL +  12V 0V T
    Bell box TerminalsHOLD  OFF
    +VE,
    STB +VETRIG -HOLD  OFF
    -VERTN S TB  -
    2 Series Terminals BELL + 12V 0V T
    Bell box TerminalsSUPPLY +
    STROBE +TRIGGER TA MP OUT S UP PLY - STROB -
    2 Series Terminals BELL + 12V 0V T
    Bell box Terminals V + S - V - TR ST -
    2 Series Terminals BELL + 12V 0V T
    Bell box Terminals HOLD + TRG HOLD- TAMP R STRB 
    						
    							105
    Galaxy 2 Series Installation Manual
    SECTION 14:  EVENT LOG LIST
    EVENTDESCRIPTION
    + AC AC zone activated
    - AC AC zone closed
    + AC> AC zone signalled
    -  AC> AC zone closed signalled
    +  CU AC Panel Mains fault
    -  CU AC Panel Mains reinstated
    +  CU AC> Mains loss signalled
    -  CU AC> Mains restored signalled
    + PSU ACRemote PSU Mains fault
    - PSU ACRemote PSU mains reinstated
    +PSU AC>Remote PSU Mains fault signalled
    - PSU AC>Remote PSU Mains reinstated
    + ASSISTAssistance zone activation
    - ASSISTAssistance zone closed
    + AUXFUSEAux fuse blown
    - AUXFUSEPanel Aux fuse fault cleared
    + BAT MIS Panel Battery disconnected
    - BAT MIS Panel Battery reconnected
    + BATTERYRemote PSU battery low (zone)
    - BATTERYRemote PSU battery low cleared (zone)
    + CU BATT Control Unit battery fail
    - CU BATT Control Unit battery fault restored
    + BELFUSEBell fuse Blown
    - BELFUSEBell fuse fault cleared
    + BELLFLT Bell fault zone activated
    - BELLFLTBell fault cleared
    + DURESSDuress Condition activated
    - DURESSDuress condition cleared
    +ENG CDE Engineer Mode accessed non EN50
    + FIREFire zone activated
    - FIREFire zone closed
    + FIRE>Fire zone signalled
    - FIRE>Fire zone closed signalled
    + FOB BAT Fob battery low
    - FOB BATFob battery fault cleared
    + INTRUIntruder zone activated
    - INTRUIntruder zone closed
    + JAM Jam condition detected
    -  JAM Jam condition cleared
    + JAM>Jam condition signalled
    + LINKLink zone activated
    - LINKLink zone closed
    + PSU BATSmart PSU battery low
    - PSU BAT Smart PSU battery Low cleared
    + PSU FUSESmart PSU fuse blown
    - PSU FUSESmart PSU fuse fault cleared
    Event Log List 
    						
    							106
    Galaxy 2 Series Installation ManualEvent Log List (cont’d)
    EVENTDESCRIPTION
    +  PA Panic zone activated
    -  PA Panic zone closed
    +  PA> Panic zone signalled
    -  PA> Panic zone closed signalled
    PA RESET PA Reset
    +  PA  SIL Silent Panic zone activated
    -  PA  SIL Silent Panic zone closed
    + PASIL>Silent Panic zone activation signalled
    - PASIL>Silent Panic zone closed signalled
    + RF BATT Wireless detector battery low
    - RF BATT Wireless detector battery low cleared
    + RF BATT> Wireless detector battery fault signalled
    + RFCHOV RF check override
    - RFCHOV RF check override restore
    + RF OVRR RF low battery override
    - RF OVRR RF low battery override restore
    + STU FLTExternal Comms Fault
    - STU FLTExternal Comms Fault cleared
    + SUPERVDetector supervision fault
    - SUPERVDetector Supervision cleared
    + SV OVER RF Supervision fail override
    - SV OVER RF Supervision fail override restore
    + TAMPER Tamper condition activated
    - TAMPER Tamper condition cleared
    +USR TMP Tamper due to wrong code
    -USR TMP Tamper due to wrong code cleared
    CANCELAlarm cancelled by user
    AUTO TSTAutomatic comms test
    CODE CHG User codes edited
    COM FAILSignalling failed
    COM RSTSignalling restored
    CONFIRMConfirmed alarm activation
    DEFAULTS Panel defaults loaded
    COMM TSTEngineer signalling test
    + REMOTERemote servicing started
    -REMOTE Remote servicing ended
    EASY SETEasy set by user
    FBAT ACK Fob low battery acknowledged
    FULL SET System full set
    FULL TSTFull test activated
    LOCKOUT Lockout due to wrong codes
    LINE FLTPhone line fault
    LINE RST Phone line restored
    + MISSINGSystem module missing
    - MISSINGSystem module reinstated
    NGHT SET System Night set
    - OVERRDEFault override cancelled
    PART SET System Part set
    + PROGRAMProgram mode enterd
    - PROGRAMProgram mode exited 
    						
    							107
    Galaxy 2 Series Installation Manual
    EVENTDESCRIPTION
    RESETSystem reset
    SOAK TSTZone soak test activation
    + OVERRDE Override of system faults
    TIM/DATE Time/Date adjusted
    - OMITZone unomitted
    UNSET System unset
    WALKTST- Walk test ended
    WALKTST+ Walk test started
    WDOG RST System reboot
    + OMITZone omitted
    ZONE TST Zone tested
    POWER ONPanel Power On
    RESTARTPanel restarted
    REARMRearm of system has occured
    + 24 HR 24 HR zone activated
    -  24  HR 24 HR zone closed
    + INT>Intruder signalled
    - INT>Intruder restore signalled
    + ENT T/OEntry Timeout alarm
    - ENT T/OEntry Timeout alarm cancelled
    + ENT T/O>Entry Timeout alarm signalled
    - ENT T/O>Entry Timeout alarm cancel signalled
    TEST END
    Event Log List (cont’d) 
    						
    							108
    Galaxy 2 Series Installation ManualSpecifications
    SECTION 15:  SPECIFICATIONS
    Table 29. Panel Specifications
    Panel Specifications2-44+ 2-20
    Physical
    Plastic Box-3 mm polycarb
    ( w it h ma ins  t r a ns fo r me r  a nd  P C B ins t a lle d )Width: 300 mm
    Height: 250 mm
    Depth: 100 mm
    We ight : 1 . 7  k gWidth: 300 mm
    Height: 250 mm
    Depth: 100 mm
    Weight: 1.7 kg
    Metal Box-1.2 mm steel
    ( w it h ma ins  t r a ns fo r me r  a nd  P C B ins t a lle d )Width: 370 mm
    Height: 320 mm
    Depth: 85 mm
    We ight : 4 . 5  k gWidth: 400 mm
    Height: 255 mm
    Depth: 115 mm
    Weight: 4.2 kg
    Electrical
    P a ne l C urre nt C o nsump tio n
    PSU Type
    Mains Input
    Back-up Battery
    P S U  M a x t o t a l lo a d
    Grade 2 Rating
    Ma x c o ntinuo us rip p le  vo lta ge
    Individual 12 V outputs:
    Be ll+ 1 2 V
    Both Aux+combined
    Trigger Header+12V
    S witc he d Outputs :
    Trigger Header Outputs
    Be ll Tr igge r  1 0 0 3
    Strobe Trigger 1004
    Trig Output 1001
    Spe ake r Output:
    Speaker output 1002
    Fus e s :
    Mains
    Battery (F1)
    Aux (F 2 )
    Be ll ( F 3 )120 mA (max)
    A
    230 V ac (+10% -15%)
    Up to 7.2Ahr 12 V Sealed
    Lead-Acid (plastic encl.)
    Up to 17Ahr 12 V Sealed
    Lead-Acid (metal encl.)
    1.4 A (nominal temp. and
    mains supply)
    1 A
    0.5 V at max. load
    500 mA max
    500 mA max
    100 mA max
    Can sink 30 mA each
    Can sink 500 mA max
    Can sink 500 mA max
    Can sink 300 mA each
    8 to 32 ohms or 100 mA in
    switched DC mode
    500 mA, 20 mm anti-surge
    (IEC 127)
    1 A, 20 mm anti-surge
    500 mA, 20 mm anti-surge
    500 mA, 20 mm anti-surge120 mA (max)
    A
    230 V ac (+10% -15%)
    Up to 7.2Ahr 12 V Sealed
    Lead-Acid (plastic encl.)
    Up to 12Ahr 12 V Sealed
    Lead-Acid (metal encl.)
    1.0 A (nominal temp. and
    mains supply)
    600 mA
    0.5 V at max. load
    500 mA max
    500 mA max
    1 0 0  mA ma x
    C a n sink  3 0  mA e a c h
    C a n sink  5 0 0  mA ma x
    C a n sink  5 0 0  mA ma x
    Can sink 300 mA each
    8 to 32 ohms or 100 mA in
    switched DC mode
    200 mA-20 mm anti-surge
    (IEC 127)
    1  A,  2 0  mm a nti- surge
    500 mA, 20 mm anti-surge
    500 mA, 20 mm anti-surge 
    						
    							109
    Galaxy 2 Series Installation ManualSpecifications (cont’d)
    Table 30. Peripheral Current Consumption
    PERIPHERAL QUIESCENT
    CURRENT (mA)MAXIMUM ALARM
    CURRENT (mA)
    Mk 7 Keyprox 90 130
    RIO 40
    P ower RIO/P ower Uni t 100
    RF P ortal 55
    6160 Keyprox 40 200
    5800 RF Receiver 60
    ECP Expander 25
    GSM Module 10 
    						
    							110
    Galaxy 2 Series Installation Manual
    SECTION 16:  COMPLIANCE AND APPROVALS
    The Galaxy 2 Series is compliant with the relevant parts of the following standards:
    • 99/05/ECR&TTE Directive
    • EN50130-5:1998Alarm systems. Environmental test methods
    It is a condition of the product’s approval that the installation complies with the following:
    EN50131 Compliance
    This product is suitable for use in systems designed to comply with PD6662:2004 and EN50131-1:2004.
    Security  Grade - 2
    Environmental Class - II
    Alarm Transmission System - 2 (options A, B, C & X)
    Power Supply Type - A
    This product is also suitable for use in alarm systems designed to comply with EN50131-1:1997.
    Security  Grade - 2
    Environmental Class - II
    Alarm Transmission System - D2, T2, A2, I0, S0
    Power Supply Type - A
    Public Switched Telephone Network (PSTN) Approval
    The equipment has been approved to Council Decision 98/482/EC for Pan -European single terminal connec-
    tion to the Public Switched Telephone Network (PSTN). However due to differences between the individual
    PSTNs provided in different countries the approval does not, of itself, give an unconditional assurance of
    successful operation on every PSTN network termination point.
    In the event of problems contact the equipment supplier in the first instance.
    The Galaxy 2 Series is designed to interwork with the following networks:
    AustriaFranceItalyNorwayUnited Kingdom
    BelgiumGreeceLiechtensteinPortugal
    Denmark IcelandLuxembourgSpain
    FinlandIrelandThe Netherlands Sweden
    NOTE:Contact the equipment supplier before using the Galaxy 2 Series on any network not listed.
    Approvals 
    						
    							111
    Galaxy 2 Series Installation Manual
    HONEYWELL SECURITY LIMITED WARRANTY
    Honeywell Security, and its divisions, subsidiaries and affiliates (“Seller”), 165 Eileen Way, Syosset, New
    York, 11791, warrants its products to be in conformance with its own plans and specifications and to be free
    from defects in materials and workmanship under normal use and service for 24 months from the date stamp
    control on the product.  Seller’s obligation shall be limited to repairing or replacing, at its option, free of charge
    for materials or labour, any product that is proved not in compliance with Seller’s specifications or proves
    defective in materials or workmanship under normal use and service. Seller shall have no obligation under this
    Limited Warranty or otherwise if the product is altered or improperly repaired or serviced by anyone other
    than Honeywell factory service. For warranty service, return product transportation prepaid to:
    Honeywell Security, 6 Aston Fields Road, Whitehouse Industrial Estate, Runcorn, Cheshire WA7
    3DL
    THERE ARE NO WARRANTIES, EXPRESS OR IMPLIED, OF MERCHANTABILITY, OR FITNESS
    FOR A PARTICULAR PURPOSE OR OTHERWISE, WHICH EXTEND BEYOND THE DESCRIP-
    TION ON THE FACE HERE OF.  IN NO CASE SHALL SELLER BE LIABLE TO ANYONE FOR
    ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER
    WARRANTY, EXPRESS OR IMPLIED, OR UPON ANY OTHER BASIS OF LIABILITY WHATSO-
    EVER, EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER’S OWN NEGLIGENCE
    OR FAULT.
    Seller does not represent that the products it sells may not be compromised or circumvented; that the prod-
    ucts will prevent any personal injury or property loss by burglary, robbery, fire or otherwise; or that the prod-
    ucts will in all cases provide adequate warning or protection.  Customer understands that a properly installed
    and maintained alarm may only reduce the risk of a burglary, robbery, fire or other events occurring without
    providing an alarm, but it is not insurance or a guarantee that such will not occur or that there will be no per-
    sonal injury or property loss as a result.
    CONSEQUENTLY, SELLER SHALL HAVE NO LIABILITY FOR ANY PERSONAL INJURY, PROP-
    ERTY DAMAGE OR OTHER LOSS BASED ON A CLAIM THE PRODUCT FAILED TO GIVE
    WARNING.  HOWEVER, IF SELLER IS HELD LIABLE, WHETHER DIRECTLY OR INDIRECTLY,
    FOR ANY LOSS OR DAMAGE ARISING UNDER THIS LIMITED WARRANTY OR OTHERWISE,
    REGARDLESS OF CAUSE OR ORIGIN, SELLER’S MAXIMUM LIABILITY SHALL NOT IN ANY
    CASE EXCEED THE PURCHASE PRICE OF THE PRODUCT, WHICH SHALL BE THE COMPLETE
    AND EXCLUSIVE REMEDY AGAINST SELLER.
    This warranty replaces any previous warranties and is the only warranty made by Seller on this product.  No
    increase or alteration, written or verbal, of the obligations of this Limited Warranty is authorized.
    Honeywell Security
    2 Redwood Crescent
    Peel Park Campus
    East Kilbride
    G74 5PA
    UK
    Warranty 
    						
    							112
    Galaxy 2 Series Installation Manual 
    						
    All Honeywell manuals Comments (0)