Home > Honeywell > Control panel > Honeywell Galaxy 2 User Manual

Honeywell Galaxy 2 User Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Honeywell Galaxy 2 User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 178 Honeywell manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							Galaxy 2 Series Installation Manual
    A-1
    Appendix A:  Point ID Comms Triggers
    Comms Triggers
    Menu  Trigger Name  Events Controlled  CID Code  SIA Code   01  Panic  Silent Panic Zone - Hotkey 
    Audible Panic Zone - Hotkey 
    Duress Code 122 
    123 
    121 HA, HR 
    PA, PR 
    HA, HR  
    02 Intruder  Intruder Zone 
    Exit Zone 
    Entry Timeout 
    Confirm 130 
    130 
    134 
    139 *BA, BR 
    BA, BR 
    BA, BR 
    BV  
    03  24 Hour  24 hour Zone 
    Link Zone 135 
    150 BA, BR 
    RO, RC  
    06 Fire  Fire Zone 
    Fire Hotkey 110 
    110 FA, FR 
    FA, FR  
    08 Omit  Zone manual omit 
    Zone force omit 573 
    573 BB 
    BB  
    09 Tamper  Zone tamper set 
    Zone tamper unset 
    Panel lid tamper (0003) 
    Module lid tamper  
    Bell tamper (0004) 
    Aux tamper 
    Missing Module 
    Keypad (Code) tamper 137 
    137 
    145 
    145 
    137 
    137 
    145 
    461 TA, TR 
    TA, TR 
    TA, TR 
    TA, TR 
    TA, TR 
    TA, TR 
    TA, TR 
    JA, TR  
    10  Set/Unset  Full Set (Areas Off) 
    Part Set 
    Night Set 
    Rearm 
    Full Unset 
    Part or night unset R401 
    R441 
    R441 
    463 
    E401 
    E441 CL 
    CG 
    CG 
    CP 
    OP 
    OG  
    11 Reset/Cancel Abort (unset from Alarm) 
    Reset  
    Reset (PA) 406 
    313 
    465 BC 
    OR 
    OR   
    13  Elec Status  Low Battery (0001) 
    Battery fail (0001) 
    Battery missing (0001) 
    Mains loss (0002) 
    Fuse fail (Any) 302 
    302 
    302 
    301 
    300 YT, YR 
    YT, YR 
    YT, YR 
    AT, AR 
    YP, YQ  
    14  System Status  Downloader Access exit 
    Manual Comms Test 
    Periodic Comms Test 
    Walk Test Active 
    Engineer Exit 412 
    601 
    602 
    607 
    628 RS 
    RX 
    RP 
    TS, TE 
    LX  
    15  System Faults  Line Fault 
    Comms Fail 
     
    Bell Fail (Zone) 351 
    350 
     
    320 LT, LR 
    YC, no restore 
    YA,YH 
      
    19  RF Faults  RF Jam 
    RF Low Battery 
    RF Supervision** 344 
    384 
    381 XQ, XH 
    XT, XR 
    See note  
    20  Assistance  Assistance Hotkey  101  QA, QR     Always on  Listen-in to follow   606  *   
     * Note : For listen-in events after alarms a SIA listen-in block is sent. There is no SIA mnemonic for listen-in.  
    **Note :   There is no specific code for RF supervision failure. The Trouble codes that are associated with  
    the usage of the transmitter should be used: 
     
    Trouble Code Transmitter Usage BT  Burglary zone trouble FT  Fire zone trouble PT  Panic zone trouble MT  Medical zone trouble QT Emergency zone trouble UT  Trouble on zone of unknown type 
     
      
    						
    							Galaxy 2 Series Installation Manual
    A-2 Honeywell Security
    2 Redwood Crescent
    Peel Park Campus
    East Kilbride
    G74 5PA
    UK
    © Copyright Honeywell Security II1-0032  Rev 1.1 
    						