83 Galaxy 2 Series Installation Manual 01 Format The communicator provides three signalling formats: • DTMF • SIA • Contact ID Once the format has been selected, the alarm and event triggers that the panel will transmit to the ARCs, may be programmed. 1 = DTMF (Dual tone Multiple Frequency) DTMF is the fast format. When DTMF format is selected, the operation of the dialler is similar to that of a hardwired 8-channel communicator. Programming Channels On selecting DTMF, the keypad displays 1 = Channels 1...
Page 92
84 Galaxy 2 Series Installation Manual 4 = Groups NOTE:The Groups attribute is only available if groups have been enabled on the system (refer to Option 63 = OPTIONS) and is also dependent upon the programmed output function for the channel. The Group attribute allows the channel to be assigned to the groups on the system; a channel can be assigned to more than one group. The channel will only trigger when an event occurs on one of the groups assigned to the channel. All channels default to all groups on...
Page 93
85 Galaxy 2 Series Installation Manual 2 = SIA (Security Industry Association) The SIA format provides a highly detailed protocol that transmits detailed information including zone descrip- tions to a PC loaded with suitable software or to a SIA compatible receiver. The SIA format is capable of transmitting over 70 different Galaxy 2 Series events (refer to Appendix A for further details). On selecting the SIA format, the keypad prompts for the required SIA level to be entered, there are 4 SIA levels...
Page 94
86 Galaxy 2 Series Installation Manual 02 Telephone No.1 Telephone number 1 must be entered. This is the main telephone number that the alarms are signalled to. Up to 20 digits may be entered, including control modifiers. Note on dial Attempts After a dialling sequence the panel waits 25 seconds from the last digit dialled, for a kiss-on tone. If nothing is received in that time, the call will be considered a fault call and that attempt terminated. Between redial at- tempts, the panel will go back on...
Page 95
87 Galaxy 2 Series Installation Manual Table 26. Panel Operation s g n i r f o o Nno i t a r e p O l e n a P 0 0sl l a c g n i m o c n i s r e w s n a r e v e n l e n a P 4 1 - 1 0sr e w s n a l e n a p e h t e r o f e b s g n i r f o r e b m u n e h t s l a u q e y r t n E 5 1ed o m t a e f e d e n i h c a m r e w s n A 09 No. of Rings This option determines the number of rings before the dialler modem answers an incoming call; the program- mable range is 00 – 15. The following table shows the panel...
Page 96
88 Galaxy 2 Series Installation Manual 10 = Line Fail This option has two settings: 0 = No When set to No there is no internal alarm or indication in the event of a telephone line fail condition. 1 = Yes If this option is set to Ye s, a line fail condition will cause a fault condition. An alert indication is given in the unset state. A Line Fail condition does not exist until 30 seconds after loss of line voltage. A line fault indication will then be given within 10 seconds if the debounce time is set to...
Page 97
89 Galaxy 2 Series Installation Manual 2 = Access Mode This option determines what authorisation is required for remote service connection. There are two options: 1 = Direct Access This permits access anytime. The remote centre can dial directly to the panel and gain access. If a call-back number is programmed in option 3, then connection must be made by the call back procedure. 2 = Manager Authorise This requires the user to authorise the remote servicing call via menu 47. The panel will not answer an...
Page 98
90 Galaxy 2 Series Installation Manual 1 = Mobile Nos 1 = Mobile 1 This selects the first mobile user. 1 = Mobile Number This is a 20 digit telephone number and is the mobile phone number of the recipient of the message. 2 = Event Type Refer to Table 27. Event types. 3 = Group Map This option selects the system group or area from which messages will be sent. 2 = Mobile 2 As per mobile 1. 3 = Mobile 3 As per mobile 1. 2 = Centre No This is a 20 digit telephone number and is the phone number of the SMS...
Page 99
91 Galaxy 2 Series Installation Manual 5 = UCP Operation This option specifies the coding of UCP SMS operation both from the panel and the replies from the SMS message centre. 1 = Call Input This option sets part of the SMS operation message from the panel to the SMS message centre to be 01 (default value). 2 = Call Input sup This option sets part of the SMS operation message from the panel to the SMS message centre to be 03. 3 = SMS Message This option sets part of the SMS operation message from the...
Page 100
92 Galaxy 2 Series Installation Manual 03 = Fire Delay This parameter determines the delay between the activation of a fire alarm and the signalling to an ARC. The Fire Delay is programmable within the range 00-60 seconds. The default is 00 seconds. 04 = Power Delay This parameter determines the delay between the activation of AC Fail outputs following a mains failure to allow the power to return before signalling the fault. The Power Delay is programmable within the range 00-60 minutes. The default is...