43
Galaxy 2 Series Installation Manual
SECTION 6:  GENERAL OPERATION
Galaxy 2 Series Users
Users are split into two main access levels under EN50131.
Level 2:Normal users who operate the system
Level 3:Engineers and master users who can alter PIN codes and system settings.
NOTE:Engineers can only alter their own PIN code
NOTE:Level 1 is considered to be the system in standby mode, where no users are currently accessing the
system.
Users
For a user to gain access, a valid PIN must be entered first. After...

Page 52

44
Galaxy 2 Series Installation Manual
To navigate around the menu and enter data, the keys are used as follows:
0-9:numeric data entry.
ent:accepts current display or enters selected option.
esc:escapes out of selected option.
A>  B

Page 53

45
Galaxy 2 Series Installation Manual
Night Setting
Enter: User code and press B.
Press 2 = Night Set
This is identical to the Part Setting procedure, except the keypad display indicates that the system is being
Night Set.  Only the zones which have the Night attribute enabled (refer to option 52.1.3 =
ZONES.Function.Night Set), are included. By default, the exit time will be silent.
Cancelling the Setting
The Full, Part and Night setting routines can be cancelled, before the system sets, by pressing...

Page 54

46
Galaxy 2 Series Installation Manual
When systems have been set up for Technistore reset, a Technistore anti-code must be entered at the keypad
to complete the restore process. If a Technistore reset is required, the restore banners shown above will be
replaced by the following:
Call ARC Call ARCCall ARC Call ARC
Call ARC
Quote XXXXX Quote XXXXXQuote XXXXX Quote XXXXX
Quote XXXXX
Where XXXXX is the quote code generated by the internal Technistore algorithm. While this is on display, the
system accepts...

Page 55

47
Galaxy 2 Series Installation Manual
Setting and Unsetting with Keyfobs
The following information applies when a radio receiver is connected to the system.
To Full Set the system (5804 Keyfob):
Press the ON button on the keyfob (Full
setting will commence as per keypad
procedure).
NOTE:To cancel the setting during the
exit time, press the OFF button.
To Unset the system:
Press the OFF button on the keyfob. (The
system unsets with a double beep).
Setting with Keyfobs
Begin Full
Set Procedure...

Page 56

48
Galaxy 2 Series Installation Manual
To Full Set the system (Mk 7 keyprox):
Hold keytag or card in front of prox symbol
for three seconds. (Full setting will com-
mence as per keypad procedure).
NOTE:To cancel the setting during the exit
time, hold keytag briefly in front of
prox symbol.
To Unset the system (Mk 7 keyprox):
Hold keytag briefly in front of prox symbol.
(The system unsets with a double beep).
1
2
3A
4
5
6B
789ent
*0#esc
Setting and Unsetting with Keytags or Cards
The following information...

Page 57

49
Galaxy 2 Series Installation Manual
Text Programming
Certain functions on the Galaxy 2 Series can be set up with text descriptors or names. When one of these is
edited the keypad will initially show the name that is currently programmed.  The A and B keys can be used to
move the edit cursor right and left in the name.  Pressing the * key will delete the character to the left of the
cursor and move the cursor one position to the left (Left Delete).  Pressing the # key will delete the character
at the...

Page 58

50
Galaxy 2 Series Installation Manual
Additional Functions
Code Tampers
When enabled (see Option 51, Parameter 14 = Lockouts), when 10 wrong codes are entered in succes-
sion, the keypad is locked. The lockout lasts for two minutes. After a further 10 wrong code entries, a tamper
is logged and a signal is given. The keypad is again locked out for two minutes.
NOTE:  RF fobs can still operate.
Conversely, if a wrong tag is presented to a keyprox or an invalid RF fob is activated for a similar number of...

Page 59

51
Galaxy 2 Series Installation Manual
SECTION 7:  MENU OPTIONS
Menu 10 - Setting Options
Option 11 - Omit Zones
This option allows zones to be temporarily removed (omitted) from the system. Once a zone has been omitted
it does not generate an alarm condition. The omit status of the zone can be toggled on and off using the # key.
The omitted zones are reinstated automatically when the system is unset or manually when the zone omit
option is disabled.
Option 12 - Timed Set
This option, when entered,...

Page 60

52
Galaxy 2 Series Installation Manual
09:04  SAT 01 JAN 09:04  SAT 01 JAN09:04  SAT 01 JAN 09:04  SAT 01 JAN
09:04  SAT 01 JAN
Full Set usr 04 Full Set usr 04Full Set usr 04 Full Set usr 04
Full Set usr 04
09:51  SAT 01 JAN 09:51  SAT 01 JAN09:51  SAT 01 JAN 09:51  SAT 01 JAN
09:51  SAT 01 JAN
LOUNGE LOUNGELOUNGE LOUNGE
LOUNGE
09:04:06   2005 09:04:06   200509:04:06   2005 09:04:06   2005
09:04:06   2005
Full Set  G12-- Full Set  G12--Full Set  G12-- Full Set  G12--
Full Set  G12--
Additional Info with...