Home > Honeywell > Scanner > Honeywell 1250g2 Manual

Honeywell 1250g2 Manual

Here you can view all the pages of manual Honeywell 1250g2 Manual. The Honeywell manuals for Scanner are available online for free. You can easily download all the documents as PDF.

Page 151

6 - 51
Addenda Timeout
You can set a time during which the scanner looks for an addenda.  If an 
addenda is not found within this time period, the data can be either trans-
mitted or discarded, based on the setting you are using for EAN/JAN-13 
Addenda Required.  Set the length (in milliseconds) for this timeout by 
scanning the bar code below, then setting the timeout (from 0-65535 milli-
seconds) by scanning digits from the Programming Chart, then scanning 
Save.  Default = 100.
Note: The Addenda...

Page 152

6 - 52
ISBN Translate
ISBNs are printed on books using the EAN-13 bar code symbology. To 
translate EAN-13 Bookland symbols into their equivalent ISBN number for-
mat, scan the On bar code below. Default = Off.
Convert ISBN to 13-Digit
When translating EAN-13 codes to the ISBN format, you can convert 
the bar code to a 13 digit format by scanning the Convert to 13-Digit 
On bar code below.  Default = Convert to 13-Digit Off.
ISBN Reformat
In normal use, the first two or three digits of an EAN-13 bar code...

Page 153

6 - 53
ISSN Translate
When On is scanned, EAN-13 977 Bookland symbols are translated into 
their equivalent 8-digit ISSN number format.  For example, 9770123456787 
will be transmitted as 01234560.  Default = Off.
ISSN Reformat
When Reformat On is scanned, EAN-13 977 Bookland symbols are 
translated into their equivalent 8-digit ISSN number format, with 
hyphens added to the output.  For example, 9770123456787 will be 
transmitted as 0123-456-0.  (You must first scan ISSN On (page 6-53) 
before scanning...

Page 154

6 - 54
EAN/JAN-8

EAN/JAN-8 On/Off
EAN/JAN-8 Check Digit
This selection allows you to specify whether the check digit should be 
transmitted at the end of the scanned data or not.  Default = On.
*  On
Off
Off *  On 

Page 155

6 - 55
EAN/JAN-8 Addenda
This selection adds 2 or 5 digits to the end of all scanned EAN/JAN-8 data.
Default = Off for both 2 Digit and 5 Digit Addenda.
EAN/JAN-8 Addenda Required
When Required is scanned, the scanner will only read EAN/JAN-8 bar 
codes that have addenda.  Default = Not Required.
Addenda Timeout
You can set a time during which the scanner looks for an addenda.  If an 
addenda is not found within this time period, the data can be either trans-
mitted or discarded, based on the setting you...

Page 156

6 - 56
scanning the bar code below, then setting the timeout (from 0-65535 milli-
seconds) by scanning digits from the Programming Chart, then scanning 
Save.  Default = 100.
Note: The Addenda Timeout setting is applied to all addenda and coupon 
code searches.
EAN/JAN-8 Addenda Separator
When this feature is On, there is a space between the data from the bar 
code and the data from the addenda.  When turned Off, there is no space.  
Default = Off.
EAN/JAN-8 Redundancy
If you are encountering errors when...

Page 157

6 - 57
MSI

MSI On/Off
MSI Check Character
Different types of check characters are used with MSI bar codes.  You can 
program the scanner to read  MSI bar codes with Type 10 check charac-
ters.  Default = Validate Type 10, but Don’t Transmit.
When Check Character is set to Validate Type 10/11 and Transmit, the 
scanner will only read MSI bar codes printed with the specified type check 
character(s), and will transmit the character(s) at the end of the scanned 
data.
On
* Off 

Page 158

6 - 58
When Check Character is set to Validate Type 10/11, but Don’t Transmit, 
the unit will only read MSI bar codes printed with the specified type check 
character(s), but will not transmit the check character(s) with the scanned 
data.
MSI Redundancy
If you are encountering errors when reading MSI bar codes, you may want 
to adjust the redundancy count.  Redundancy adjusts the number of times 
a bar code is decoded before transmission, which may reduce the number 
of errors.  Note that the higher the...

Page 159

6 - 59
MSI Message Length
Scan the bar codes below to change the message length.  Refer to 
Message Length Description (page 6-2) for additional information.  Mini-
mum and Maximum lengths = 1-80.   Minimum Default = 3, Maximum 
Default = 80.
Plessey Code
< Default All Plessey Code Settings >
Plessey Code On/Off
Plessey Check Character
No Check Character indicates that the scanner reads and transmits bar 
code data with or without a check character.
When Check Character is set to Validate, but Don’t...

Page 160

6 - 60
When Check Character is set to Validate and Transmit, the scanner only 
reads Plessey bar codes printed with a check character, and will transmit 
this character at the end of the scanned data.  Default = No Check Charac-
ter.
Plessey Redundancy
If you are encountering errors when reading Plessey bar codes, you may 
want to adjust the redundancy count.  Redundancy adjusts the number of 
times a bar code is decoded before transmission, which may reduce the 
number of errors.  Note that the higher...
Start reading Honeywell 1250g2 Manual

Related Manuals for Honeywell 1250g2 Manual

All Honeywell manuals