Home > Honeywell > Scanner > Honeywell 1250g2 Manual

Honeywell 1250g2 Manual

Here you can view all the pages of manual Honeywell 1250g2 Manual. The Honeywell manuals for Scanner are available online for free. You can easily download all the documents as PDF.

Page 201

9 - 27
Codabar Check 
Char.*No Check Char. CBRCK206-4
Validate Modulo 16, 
But Don’t TransmitCBRCK216-4
Validate Modulo 16, 
and TransmitCBRCK226-4
Validate Modulo 7 
CD, But Don’t 
Tr a n s m i tCBRCK236-4
Validate Modulo 7 
CD, and TransmitCBRCK246-4
Validate CLSI, But 
Don’t TransmitCBRCK256-4
Validate CLSI, and 
Tr a n s m i tCBRCK266-4
Codabar 
Concatenation*Off CBRCCT06-5
On CBRCCT16-5
Require CBRCCT26-5
Concatenation 
TimeoutDLYCCT6-5
Codabar 
RedundancyRange (0 - 10) *0 CBRVOT##6-5
Codabar...

Page 202

9 - 28
Code 39 Check Char.*No Check Char. C39CK206-8
Validate, But Don’t 
Tr a n s m i tC39CK216-8
Validate, 
and TransmitC39CK226-8
Code 39 
RedundancyRange (0 - 10) *0 C39VOT##6-8
Code 39 Message 
LengthMinimum (1 - 80)  *3 C39MIN##6-8
Maximum (1 - 80)  
*80C39MAX##6-8
Code 32 
Pharmaceutical 
(PARAF)*Off C39B3206-9
On C39B3216-9
Code 39 Full ASCII *Off C39ASC06-10
On C39ASC16-10
Interleaved 2 of 5 Default All 
Interleaved
2 of 5 SettingsI25DFT6-10
Off I25ENA06-10
*On I25ENA16-10
NULL Characters *Off...

Page 203

9 - 29
NEC 2 of 5 Default All NEC
2 of 5 SettingsN25DFT6-12
*Off N25ENA06-12
On N25ENA16-12
NEC 2 of 5 Check 
Digit*No Check Char. N25CK206-13
Validate, But Don’t 
Tr a n s m i tN25CK216-13
Validate, and 
Tr a n s m i tN25CK226-13
NEC 2 of 5 
RedundancyRange (0 - 10) *0 N25VOT##6-13
NEC 2 of 5 Message 
LengthMinimum (1 - 80)  *3 N25MIN##6-13
Maximum (1 - 80)  
*80N25MAX##6-13
Code 93 Default All Code 93 
SettingsC93DFT6-14
Off C93ENA06-14
*On C93ENA16-15
Code 93 
RedundancyRange (0 - 10) *0 C93VOT##6-14...

Page 204

9 - 30
Straight  2 of 5 IATA Default All Straight 2 
of 5 IATA
SettingsA25DFT6-17
Straight  2 of 5 IATA *Off A25ENA06-17
On A25ENA16-17
Straight  2 of 5 IATA 
RedundancyRange (0 - 10) *0 A25VOT##6-17
Straight  2 of 5 IATA 
Message LengthMinimum (1 - 80)  
*13A25MIN##6-18
Maximum (1 - 80)  
*15A25MAX##6-18
Matrix 2 of 5 Default All Matrix 2 
of 5
SettingsX25DFT6-18
*Off X25ENA06-18
On X25ENA16-18
Matrix 2 of 5 
RedundancyRange (0 - 10) *0 X25VOT##6-19
Matrix 2 of 5 
Message LengthMinimum (1 - 80)  *3...

Page 205

9 - 31
Code 11 Check 
Digits Required1 Check Digit 
RequiredC11CK206-20
*2 Check Digits 
RequiredC11CK216-20
Auto Select Check 
Digits RequiredC11CK226-20
Check Digit 
ValidationValidate and 
Transmit One Check 
DigitC11CK236-21
Validate and 
Tr a n s m i t  Tw o  C h e c k  
DigitsC11CK246-21
Validate and 
Tr a n s m i t  A u t o  S e l e c t  
Check DigitsC11CK256-21
Code 11 
RedundancyRange (0 - 10) *0 C11VOT##6-21
Code 11 Message 
LengthMinimum (1 - 80)  *3 C11MIN##6-22
Maximum (1 - 80)...

Page 206

9 - 32
ISBT128 Predefined 
Concatenation 
Sequences* Donation ID 
Number (001)
and ABO/RhD Blood 
Groups (002)ISBPCS06-25
Donation ID Number 
(001) and
Donor ID Number 
(019)ISBPCS16-25
Donation ID Number 
(001) and 
Confidential Unit 
Exclusion StatusISBPCS26-25
Product Code (003) 
and Expiration Date 
(Form 1)ISBPCS36-25
Product Code (003) 
and Expiration Date 
(Form 2)ISBPCS46-25
Product Code (003) 
and Expiration Date 
(Form 3)ISBPCS56-25
Product Code (003) 
and Expiration Date 
(Form 4)ISBPCS66-25...

Page 207

9 - 33
ISBT 128 User-
Defined 
Concatenation 
Sequences1st Left Identifier (0-
255) *0ISBUL1##6-27
2nd Left Identifier (0-
255) *0ISBUL2##6-27
1st Right Identifier 
(0-255) *0ISBUR1##6-27
2nd Right Identifier 
(0-255) *0ISBUR2##6-27
ISBT 128 User-
Defined 
Concatenation 
Sequences On/Off*Off ISBUCE06-28
Allow User-Defined 
SequenceISBUCE16-28
Require User-
Defined SequenceISBUCE26-28
Content Verification *Off ISBXM006-28
On ISBXM016-28
Transmit Identifiers Off ISBXM106-29
*On ISBXM116-29
Flag Conversion...

Page 208

9 - 34
Telepen Default All Telepen
SettingsTELDFT6-32
*Off TELENA06-32
On TELENA16-32
Telepen Output *AIM Telepen Output TELOLD06-32
Original Telepen 
OutputTELOLD16-32
Telepen Redundancy Range (0 - 10) *0 TELVOT##6-33
Telepen Message 
LengthMinimum (1 - 80)  *3 TELMIN##6-33
Maximum (1 - 80)  
*80TELMAX##6-33
UPC-A Default All 
UPC-A SettingsUPADFT6-33
Off UPBENA06-34
*On UPBENA16-34
UPC-A Number 
SystemOff UPANSX06-34
*On UPANSX16-34
UPC-A Check Digit Off UPACKX06-33
*On UPACKX16-34
UPC-A 2 Digit...

Page 209

9 - 35
UPC-A/EAN-13 with 
Extended Coupon 
Code*Off CPNENA06-37
Allow Concatenation CPNENA16-37
Require 
ConcatenationCPNENA26-37
UPC-A Number 
System 4 Addenda 
Required* Don’t Require 
Coupon CodeARQSY406-37
Require Coupon 
CodeARQSY416-37
UPC-A Number 
System 5 Addenda 
Required* Don’t Require 
Coupon Code/
AddendaARQSY506-38
Require 2 Digit 
AddendaARQSY516-38
Require 5 Digit 
AddendaARQSY526-38
Require 2 or 5 Digit 
AddendaARQSY536-38
Require Coupon 
CodeARQSY546-38
Require Coupon 
Code or 2 Digit...

Page 210

9 - 36
UPC-E0 Expand *Off UPEEXP06-40
On UPEEXP16-40
UPC-E0 Number 
System*On UPEEXN16-40
Off UPEEXN06-40
UPC-E0 Check Digit *Off UPECKX06-41
On UPECKX16-41
UPC-E0 Leading 
Zero*Off UPENSX06-41
On UPENSX16-41
UPC-E0 Addenda 2 Digit Addenda On UPEAD216-42
*2 Digit Addenda Off UPEAD206-42
5 Digit Addenda On UPEAD516-42
*5 Digit Addenda Off UPEAD506-42
UPC-E0 Addenda 
RequiredRequired UPEARQ16-42
*Not Required UPEARQ06-42
Addenda Timeout Range (0 - 65535) 
*100DLYADD#####6-43
UPC-E0 Addenda 
SeparatorOn...
Start reading Honeywell 1250g2 Manual

Related Manuals for Honeywell 1250g2 Manual

All Honeywell manuals