Home > Honeywell > Scanner > Honeywell 1250g2 Manual

Honeywell 1250g2 Manual

Here you can view all the pages of manual Honeywell 1250g2 Manual. The Honeywell manuals for Scanner are available online for free. You can easily download all the documents as PDF.

Page 141

6 - 41
UPC-E0 Number System and Check Digit
UPC-E0 Check Digit
Check Digit specifies whether the check digit should be transmitted at 
the end of the scanned data or not.  Default = Off.
UPC-E0 Leading Zero
This feature allows the transmission of a leading zero (0) at the beginning 
of scanned data.  To prevent transmission, scan Off.  Default = Off.
Check 
Digit Number
System
UPC-E0 sample showing the number system and check digit:
* Off  On
* Off On 

Page 142

6 - 42
UPC-E0 Addenda
This selection adds 2 or 5 digits to the end of all scanned UPC-E data.
Default = Off for both 2 Digit and 5 Digit Addenda.
UPC-E0 Addenda Required
When Required is scanned, the scanner will only read UPC-E bar codes 
that have addenda.  Default = Not Required.
Addenda Timeout
You can set a time during which the scanner looks for an addenda.  If an 
addenda is not found within this time period, the data can be either trans-
mitted or discarded, based on the setting you are using for...

Page 143

6 - 43
timeout by scanning the bar code below, then setting the timeout (from 0-
65535 milliseconds) by scanning digits from the Programming Chart, then 
scanning Save.  Default = 100.
Note: The Addenda Timeout setting is applied to all addenda and coupon 
code searches.
UPC-E0 Addenda Separator
When this feature is On, there is a space between the data from the bar 
code and the data from the addenda.  When turned Off, there is no space.  
Default = Off.
UPC-E0 Redundancy
If you are encountering errors...

Page 144

6 - 44
EAN/JAN-13

EAN/JAN-13 On/Off
Convert UPC-A to EAN-13
When UPC-A Converted to EAN-13 is selected, UPC-A bar codes are 
converted to 13 digit EAN-13 codes by adding a zero to the front.  When 
Do not Convert UPC-A is selected, UPC-A codes are read as UPC-A.
*  On
Off
* Do Not Convert  UPC-A UPC-A Converted to EAN-13 

Page 145

6 - 45
EAN/JAN-13 Check Digit
This selection allows you to specify whether the check digit should be 
transmitted at the end of the scanned data or not.  Default = On.
EAN/JAN-13 Addenda
This selection adds 2 or 5 digits to the end of all scanned EAN/JAN-13 
data.  Default = Off for both 2 Digit and 5 Digit Addenda.
EAN/JAN-13 Addenda Required
When Required is scanned, the scanner will only read EAN/JAN-13 bar 
codes that have addenda.  Default = Not Required.
Off *  On
* 5 Digit Addenda Off 5 Digit...

Page 146

6 - 46
EAN-13 Beginning with 2 Addenda Required
This setting programs the scanner to require a 2 digit addenda only on 
EAN-13 bar codes that begin with a “2.”  The following settings can be pro-
grammed:
Require 2 Digit Addenda:  All EAN-13 bar codes that begin with a “2” 
must have a 2 digit addendum.  The EAN-13 bar code with the 2 digit 
addendum is then transmitted as a single, concatenated bar code.  If a 2 
digit addendum is not found within the Addenda Timeout period, the EAN-
13 bar code is...

Page 147

6 - 47
Default = Don’t Require 5 Digit Addenda.
EAN-13 Beginning with 378/379 
Addenda Required 
This setting programs the scanner to require any combination of a 2 digit 
addenda or a 5 digit addenda on EAN-13 bar codes that begin with a “378” 
or “379.”  The following settings can be programmed:
Require Addenda:  All EAN-13 bar codes that begin with a “378” or “379” 
must have a 2 digit addenda, a 5 digit addenda, or a combination of these 
addenda.  The EAN-13 bar code with the addenda is then...

Page 148

6 - 48
EAN-13 Beginning with 414/419 
Addenda Required 
This setting programs the scanner to require any combination of a 2 digit 
addenda or a 5 digit addenda on EAN-13 bar codes that begin with a “414” 
or “419.”  The following settings can be programmed:
Require Addenda:  All EAN-13 bar codes that begin with a “414” or “419” 
must have a 2 digit addenda, a 5 digit addenda, or a combination of these 
addenda.  The EAN-13 bar code with the addenda is then transmitted as a 
single, concatenated bar code....

Page 149

6 - 49
Default = Don’t Require Addenda.
EAN-13 Beginning with 977 Addenda Required
This setting programs the scanner to require a 2 digit addenda only on 
EAN-13 bar codes that begin with “977.”  The following settings can be pro-
grammed:
Require 2 Digit Addenda:  All EAN-13 bar codes that begin with “977” 
must have a 2 digit addendum.  The EAN-13 bar code with the 2 digit 
addendum is then transmitted as a single, concatenated bar code.  If a 2 
digit addendum is not found within the Addenda Timeout...

Page 150

6 - 50
Require 5 Digit Addenda:  All EAN-13 bar codes that begin with “978” 
must have a 5 digit addendum.  The EAN-13 bar code with the 5 digit 
addendum is then transmitted as a single, concatenated bar code.  If a 5 
digit addendum is not found within the Addenda Timeout period, the EAN-
13 bar code is discarded.
Don’t Require 5 Digit Addenda:  If you have selected Require 5 Digit 
Addenda, and you want to disable this feature, scan Don’t Require 5 Digit 
Addenda.  EAN-13 bar codes are transmitted,...