6 - 11
Check Digit
No Check Digit indicates that the scanner reads and transmits bar code 
data with or without a check digit.
When Check Digit is set to Validate, but Don’t Transmit, the unit only 
reads Interleaved 2 of 5 bar codes printed with a check digit, but will not 
transmit the check digit with the scanned data.  
When Check Digit is set to Validate and Transmit, the scanner only reads 
Interleaved 2 of 5 bar codes printed with a check digit, and will transmit this 
digit at the end of the...

Page 112

6 - 12
Interleaved 2 of 5 Message Length
Scan the bar codes below to change the message length.  Refer to 
Message Length Description (page 6-2) for additional information.  Mini-
mum and Maximum lengths = 1-80.  Minimum Default = 6, Maximum 
Default = 80.
NEC 2 of 5
< Default All NEC 2 of 5 Settings >
NEC 2 of 5 On/Off
Check Digit
No Check Digit indicates that the scanner reads and transmits bar code 
data with or without a check digit.
When Check Digit is set to Validate, but Don’t Transmit, the unit...

Page 113

6 - 13
When Check Digit is set to Validate and Transmit, the scanner only reads 
NEC 2 of 5 bar codes printed with a check digit, and will transmit this digit 
at the end of the scanned data.  Default = No Check Digit.
NEC 2 of 5 Redundancy
If you are encountering errors when reading NEC 2 of 5 bar codes, you 
may want to adjust the redundancy count.  Redundancy adjusts the num-
ber of times a bar code is decoded before transmission, which may reduce 
the number of errors.  Note that the higher the...

Page 114

6 - 14
Code 93
< Default All Code 93 Settings >
Code 93 On/Off
Code 93 Redundancy
If you are encountering errors when reading Code 93 bar codes, you may 
want to adjust the redundancy count.  Redundancy adjusts the number of 
times a bar code is decoded before transmission, which may reduce the 
number of errors.  Note that the higher the redundancy count, the longer it 
will take to decode the bar code.  To adjust the redundancy, scan the Code 
93 Redundancy bar code below, then scan a redundancy count...

Page 115

6 - 15
Code 93 Message Length
Scan the bar codes below to change the message length.  Refer to 
Message Length Description (page 6-2) for additional information.  Mini-
mum and Maximum lengths = 1-80.  Minimum Default = 3, Maximum 
Default = 80.
Straight 2 of 5 Industrial (three-bar start/stop)

Straight 2 of 5 Industrial On/Off
Straight 2 of 5 Industrial Redundancy
If you are encountering errors when reading Straight 2 of 5 Industrial bar 
codes, you may want to adjust the redundancy count.  Redundancy...

Page 116

6 - 16
scan a redundancy count between 0 and 10 on the Programming Chart 
inside the back cover of this manual.  Then scan the Save bar code.  
Default = 0.
Straight 2 of 5 Industrial Message Length
Scan the bar codes below to change the message length.  Refer to 
Message Length Description (page 6-2) for additional information.  Mini-
mum and Maximum lengths = 1-80.  Minimum Default = 3, Maximum 
Default = 80.
Straight 2 of 5 Industrial 
Redundancy
Minimum Message Length
Maximum Message Length 

Page 117

6 - 17
Straight 2 of 5 IATA (two-bar start/stop)
Note: This symbology is also known as Airline Code 5.

Straight 2 of 5 IATA On/Off
Straight 2 of 5 IATA Redundancy
If you are encountering errors when reading Straight 2 of 5 IATA bar codes, 
you may want to adjust the redundancy count.  Redundancy adjusts the 
number of times a bar code is decoded before transmission, which may 
reduce the number of errors.  Note that the higher the redundancy count, 
the longer it will take to decode the bar code.  To...

Page 118

6 - 18
Straight 2 of 5 IATA Message Length
Scan the bar codes below to change the message length.  Refer to 
Message Length Description (page 6-2) for additional information.  Mini-
mum and Maximum lengths = 1-80.  Minimum Default = 13, Maximum 
Default = 15.
Matrix 2 of 5

Matrix 2 of 5 On/Off
Matrix 2 of 5 Check Character
No Check Character indicates that the scanner reads and transmits bar 
code data with or without a check character.
When Check Character is set to Validate, but Don’t Transmit, the...

Page 119

6 - 19
When Check Character is set to Validate and Transmit, the scanner only 
reads Matrix 2 of 5 bar codes printed with a check character, and will trans-
mit this character at the end of the scanned data.  Default = No Check 
Character.
Matrix 2 of 5 Redundancy
If you are encountering errors when reading Matrix 2 of 5 bar codes, you 
may want to adjust the redundancy count.  Redundancy adjusts the num-
ber of times a bar code is decoded before transmission, which may reduce 
the number of errors....

Page 120

6 - 20
Code 11

Code 11 On/Off
Check Digits Required
These options set whether 1 or 2 check digits are required with Code 11 
bar codes.  Auto Select Check Digits determines the number of check 
digits based on the length of the bar code.  If the bar code is 10 digits or 
more, 2 check digits are required.  If it is 9 digits or less, 1 check digit is 
required.  The check digit data is only transmitted if you program that fea-
ture (see Check Digit Validation on page 6-21).  Default = Two Check Digits...