Page 131

6 - 31
128 Redundancy bar code below, then scan a redundancy count between 
0 and 10 on the Programming Chart inside the back cover of this manual.  
Then scan the Save bar code.  Default = 0.
GS1-128 Message Length
Scan the bar codes below to change the message length.  Refer to 
Message Length Description (page 6-2) for additional information.  Mini-
mum and Maximum lengths = 1-80.   Minimum Default = 3, Maximum 
Default = 80.
GS1-128 Redundancy
Minimum Message Length
Maximum Message Length 

Page 132

6 - 32
Te l e p e n

Telepen On/Off
Telepen Output
Using AIM Telepen Output, the scanner reads symbols with start/stop pat-
tern 1 and decodes them as standard full ASCII (start/stop pattern 1).  
When Original Telepen Output is selected, the scanner reads symbols with 
start/stop pattern 1 and decodes them as compressed numeric with 
optional full ASCII (start/stop pattern 2).  Default = AIM Telepen Output.
Telepen Redundancy
If you are encountering errors when reading Telepen bar codes, you may 
want...

Page 133

6 - 33
Telepen Redundancy bar code below, then scan a redundancy count 
between 0 and 10 on the Programming Chart inside the back cover of this 
manual.  Then scan the Save bar code.  Default = 0.
Telepen Message Length
Scan the bar codes below to change the message length.  Refer to 
Message Length Description (page 6-2) for additional information.  Mini-
mum and Maximum lengths = 1-80.   Minimum Default = 3, Maximum 
Default = 80.
UPC-A

UPC-A On/Off
Note: To convert UPC-A bar codes to EAN-13, see...

Page 134

6 - 34
UPC-A Number System and Check Digit
UPC-A Number System
The numeric system digit of a U.P.C. symbol is normally transmitted at 
the beginning of the scanned data, but the  can be programmed so it 
will not transmit it.   Default = On.
UPC-A Check Digit
This selection allows you to specify whether the check digit should be 
transmitted at the end of the scanned data or not.  Default = On.
Check 
Digit Number
System
UPC-A sample showing the number system and check digit:
Off *  On
*  On
Off 

Page 135

6 - 35
UPC-A Addenda
This selection adds 2 or 5 digits to the end of all scanned UPC-A data.
Default = Off for both 2 Digit and 5 Digit Addenda.
UPC-A Addenda Required
When Required is scanned, the scanner will only read UPC-A bar codes 
that have addenda.  You must then turn on  a 2 or 5 digit addenda listed on 
page 6-35.  Default = Not Required.
Addenda Timeout
You can set a time during which the scanner looks for an addenda.  If an 
addenda is not found within this time period, the data can be either...

Page 136

6 - 36
timeout by scanning the bar code below, then setting the timeout (from 0-
65535 milliseconds) by scanning digits from the Programming Chart, then 
scanning Save.  Default = 100.
Note: The Addenda Timeout setting is applied to all addenda and coupon 
code searches.
UPC-A Addenda Separator  
When this feature is on, there is a space between the data from the bar 
code and the data from the addenda.  When turned off, there is no space.  
Default = Off.
UPC-A Redundancy
If you are encountering errors...

Page 137

6 - 37
If you scan the Allow Concatenation code, when the scanner sees the coupon 
code and the extended coupon code in a single scan, it transmits both as sepa-
rate symbologies.  Otherwise, it transmits the first coupon code it reads.  
If you scan the Require Concatenation code, the scanner must see and read 
the coupon code and extended coupon code in a single read to transmit the 
data.  No data is output unless both codes are read. 
Default = Off.
UPC-A Number System 4 Addenda Required 
This...

Page 138

6 - 38
UPC-A Number System 5 Addenda Required 
This setting programs the scanner to require any combination of a coupon 
code, a 2 digit addenda, or a 5 digit addenda on UPC-A bar codes that 
begin with a “5.”  The following settings can be programmed:
Require Coupon Code/Addenda:  All UPC-A bar codes that begin with a 
“5” must have a coupon code, a 2 digit addenda, a 5 digit addenda, or a 
combination of these addenda.  The UPC-A bar code with the coupon code 
and/or addenda is then transmitted as a...

Page 139

6 - 39
Addenda Timeout
You can set a time during which the scanner looks for a coupon code.  If a 
coupon code is not found within this time period, the data can be either 
transmitted or discarded, based on the setting you are using for UPC-A/
EAN-13 with Extended Coupon Code or UPC-A Number System 4 
Addenda Required.  Set the length (in milliseconds) for this timeout by 
scanning the bar code below, then setting the timeout (from 0-65535 milli-
seconds) by scanning digits from the Programming Chart,...

Page 140

6 - 40
UPC-E0 Expand
UPC-E Expand expands the UPC-E code to the 12 digit, UPC-A format.  
Default = Off.
UPC-E0 Number System
The numeric system digit of a UPC-A symbol is normally transmitted at the 
beginning of scanned data.  When using UPC-E Expand, the unit can be 
programmed so it will not transmit it.  Default = On.
On
*  Off
Off *  On 