6 - 41 UPC-E0 Number System and Check Digit UPC-E0 Check Digit Check Digit specifies whether the check digit should be transmitted at the end of the scanned data or not. Default = Off. UPC-E0 Leading Zero This feature allows the transmission of a leading zero (0) at the beginning of scanned data. To prevent transmission, scan Off. Default = Off. Check Digit Number System UPC-E0 sample showing the number system and check digit: * Off On * Off On
6 - 42 UPC-E0 Addenda This selection adds 2 or 5 digits to the end of all scanned UPC-E data. Default = Off for both 2 Digit and 5 Digit Addenda. UPC-E0 Addenda Required When Required is scanned, the scanner will only read UPC-E bar codes that have addenda. Default = Not Required. Addenda Timeout You can set a time during which the scanner looks for an addenda. If an addenda is not found within this time period, the data can be either trans- mitted or discarded, based on the setting you are using for UPC-E0 Addenda Required (page 6-42). Set the length (in milliseconds) for this * 5 Digit Addenda Off 5 Digit Addenda On* 2 Digit Addenda Off 2 Digit Addenda On * Not Required Required
6 - 43 timeout by scanning the bar code below, then setting the timeout (from 0- 65535 milliseconds) by scanning digits from the Programming Chart, then scanning Save. Default = 100. Note: The Addenda Timeout setting is applied to all addenda and coupon code searches. UPC-E0 Addenda Separator When this feature is On, there is a space between the data from the bar code and the data from the addenda. When turned Off, there is no space. Default = Off. UPC-E0 Redundancy If you are encountering errors when reading UPC-E0 bar codes, you may want to adjust the redundancy count. Redundancy adjusts the number of times a bar code is decoded before transmission, which may reduce the number of errors. Note that the higher the redundancy count, the longer it will take to decode the bar code. To adjust the redundancy, scan the UPC- E0 Redundancy bar code below, then scan a redundancy count between 0 and 10 on the Programming Chart inside the back cover of this manual. Then scan the Save bar code. Default = 1. Addenda Timeout * Off On UPC-E0 Redundancy
6 - 44 EAN/JAN-13 EAN/JAN-13 On/Off Convert UPC-A to EAN-13 When UPC-A Converted to EAN-13 is selected, UPC-A bar codes are converted to 13 digit EAN-13 codes by adding a zero to the front. When Do not Convert UPC-A is selected, UPC-A codes are read as UPC-A. * On Off * Do Not Convert UPC-A UPC-A Converted to EAN-13
6 - 45 EAN/JAN-13 Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not. Default = On. EAN/JAN-13 Addenda This selection adds 2 or 5 digits to the end of all scanned EAN/JAN-13 data. Default = Off for both 2 Digit and 5 Digit Addenda. EAN/JAN-13 Addenda Required When Required is scanned, the scanner will only read EAN/JAN-13 bar codes that have addenda. Default = Not Required. Off * On * 5 Digit Addenda Off 5 Digit Addenda On* 2 Digit Addenda Off 2 Digit Addenda On * Not Required Required
6 - 46 EAN-13 Beginning with 2 Addenda Required This setting programs the scanner to require a 2 digit addenda only on EAN-13 bar codes that begin with a “2.” The following settings can be pro- grammed: Require 2 Digit Addenda: All EAN-13 bar codes that begin with a “2” must have a 2 digit addendum. The EAN-13 bar code with the 2 digit addendum is then transmitted as a single, concatenated bar code. If a 2 digit addendum is not found within the Addenda Timeout period, the EAN- 13 bar code is discarded. Note: if you are using EAN-13 Beginning with 290 Addenda Required (page 6-46), that setting will take precedence over this one. Don’t Require 2 Digit Addenda: If you have selected Require 2 Digit Addenda, and you want to disable this feature, scan Don’t Require 2 Digit Addenda. EAN-13 bar codes are transmitted, depending on the setting you are using for EAN/JAN-13 Addenda Required. Default = Don’t Require 2 Digit Addenda. EAN-13 Beginning with 290 Addenda Required This setting programs the scanner to require a 5 digit addenda only on EAN-13 bar codes that begin with “290.” The following settings can be pro- grammed: Require 5 Digit Addenda: All EAN-13 bar codes that begin with “290” must have a 5 digit addendum. The EAN-13 bar code with the 5 digit addendum is then transmitted as a single, concatenated bar code. If a 5 digit addendum is not found within the Addenda Timeout period, the EAN- 13 bar code is discarded. Note: if you are using EAN-13 Beginning with 2 Addenda Required (page 6-46), this setting will take precedence. Don’t Require 5 Digit Addenda: If you have selected Require 5 Digit Addenda, and you want to disable this feature, scan Don’t Require 5 Digit Addenda. EAN-13 bar codes are transmitted, depending on the setting you are using for EAN/JAN-13 Addenda Required. Require 2 Digit Addenda * Don’t Require 2 Digit Addenda
6 - 47 Default = Don’t Require 5 Digit Addenda. EAN-13 Beginning with 378/379 Addenda Required This setting programs the scanner to require any combination of a 2 digit addenda or a 5 digit addenda on EAN-13 bar codes that begin with a “378” or “379.” The following settings can be programmed: Require Addenda: All EAN-13 bar codes that begin with a “378” or “379” must have a 2 digit addenda, a 5 digit addenda, or a combination of these addenda. The EAN-13 bar code with the addenda is then transmitted as a single, concatenated bar code. If the required addenda is not found within the Addenda Timeout period, the EAN-13 bar code is discarded. Don’t Require Addenda: If you have selected Require Addenda, and you want to disable this feature, scan Don’t Require Addenda. EAN-13 bar codes are transmitted, depending on the setting you are using for EAN/ JAN-13 Addenda Required. Default = Don’t Require Addenda. Require 5 Digit Addenda * Don’t Require 5 Digit Addenda Require 2 Digit Addenda * Don’t Require Addenda Require 5 Digit Addenda Require 2 or 5 Digit Addenda
6 - 48 EAN-13 Beginning with 414/419 Addenda Required This setting programs the scanner to require any combination of a 2 digit addenda or a 5 digit addenda on EAN-13 bar codes that begin with a “414” or “419.” The following settings can be programmed: Require Addenda: All EAN-13 bar codes that begin with a “414” or “419” must have a 2 digit addenda, a 5 digit addenda, or a combination of these addenda. The EAN-13 bar code with the addenda is then transmitted as a single, concatenated bar code. If the required addenda is not found within the Addenda Timeout period, the EAN-13 bar code is discarded. Don’t Require Addenda: If you have selected Require Addenda, and you want to disable this feature, scan Don’t Require Addenda. EAN-13 bar codes are transmitted, depending on the setting you are using for EAN/ JAN-13 Addenda Required. Default = Don’t Require Addenda. EAN-13 Beginning with 434/439 Addenda Required This setting programs the scanner to require any combination of a 2 digit addenda or a 5 digit addenda on EAN-13 bar codes that begin with a “434” or “439.” The following settings can be programmed: Require Addenda: All EAN-13 bar codes that begin with a “434” or “439” must have a 2 digit addenda, a 5 digit addenda, or a combination of these addenda. The EAN-13 bar code with the addenda is then transmitted as a single, concatenated bar code. If the required addenda is not found within the Addenda Timeout period, the EAN-13 bar code is discarded. Don’t Require Addenda: If you have selected Require Addenda, and you want to disable this feature, scan Don’t Require Addenda. EAN-13 bar codes are transmitted, depending on the setting you are using for EAN/ JAN-13 Addenda Required. Require 2 Digit Addenda * Don’t Require Addenda Require 5 Digit Addenda Require 2 or 5 Digit Addenda
6 - 49 Default = Don’t Require Addenda. EAN-13 Beginning with 977 Addenda Required This setting programs the scanner to require a 2 digit addenda only on EAN-13 bar codes that begin with “977.” The following settings can be pro- grammed: Require 2 Digit Addenda: All EAN-13 bar codes that begin with “977” must have a 2 digit addendum. The EAN-13 bar code with the 2 digit addendum is then transmitted as a single, concatenated bar code. If a 2 digit addendum is not found within the Addenda Timeout period, the EAN- 13 bar code is discarded. Don’t Require 2 Digit Addenda: If you have selected Require 2 Digit Addenda, and you want to disable this feature, scan Don’t Require 2 Digit Addenda. EAN-13 bar codes are transmitted, depending on the setting you are using for EAN/JAN-13 Addenda Required. Default = Don’t Require 2 Digit Addenda. EAN-13 Beginning with 978 Addenda Required These settings program the scanner to require a 5 digit addenda only on EAN-13 bar codes that begin with “978.” The following settings can be pro- grammed: Require 2 Digit Addenda * Don’t Require Addenda Require 5 Digit Addenda Require 2 or 5 Digit Addenda Require 2 Digit Addenda * Don’t Require 2 Digit Addenda
6 - 50 Require 5 Digit Addenda: All EAN-13 bar codes that begin with “978” must have a 5 digit addendum. The EAN-13 bar code with the 5 digit addendum is then transmitted as a single, concatenated bar code. If a 5 digit addendum is not found within the Addenda Timeout period, the EAN- 13 bar code is discarded. Don’t Require 5 Digit Addenda: If you have selected Require 5 Digit Addenda, and you want to disable this feature, scan Don’t Require 5 Digit Addenda. EAN-13 bar codes are transmitted, depending on the setting you are using for EAN/JAN-13 Addenda Required. Default = Don’t Require 5 Digit Addenda. EAN-13 Beginning with 979 Addenda Required These settings program the scanner to require a 5 digit addenda only on EAN-13 bar codes that begin with “979.” The following settings can be pro- grammed: Require 5 Digit Addenda: All EAN-13 bar codes that begin with “979” must have a 5 digit addendum. The EAN-13 bar code with the 5 digit addendum is then transmitted as a single, concatenated bar code. If a 5 digit addendum is not found within the Addenda Timeout period, the EAN- 13 bar code is discarded. Don’t Require 5 Digit Addenda: If you have selected Require 5 Digit Addenda, and you want to disable this feature, scan Don’t Require 5 Digit Addenda. EAN-13 bar codes are transmitted, depending on the setting you are using for EAN/JAN-13 Addenda Required. Default = Don’t Require 5 Digit Addenda. Require 5 Digit Addenda * Don’t Require 5 Digit Addenda Require 5 Digit Addenda * Don’t Require 5 Digit Addenda