    							9 - 17
    NCR ACK/NAK *NCR ACK/NAK Off NCRACK02-31
    NCR ACK/NAK On NCRACK12-31
    Block Check 
    Character*Transmit NCRBCC12-32
    Don’t Transmit  NCRBCC02-32
    NCR Prefix/Suffix NCR Prefix NCRPR2##2-32
    NCR Suffix NCRSF2##2-32
    Transmit Prefix/
    SuffixNCRBCP12-33
    *Don’t Transmit 
    Prefix/SuffixNCRBCP02-33
    NCR NOF (Not-on-
    File) ErrorOn NCRRAZ12-33
    *Off NCRRAZ02-33
    Scanner to Bioptic 
    Communication
     *Packet Mode Off 232PKT02-34
    Packet Mode On 232PKT22-34
    *ACK/NAK Off 232ACK02-34
    ACK/NAK On 232ACK12-34
    Communication 
    Timeout
    (Range 1-65535) 
    *2000 ms232DLK#####2-34
    Input/Output Selections
    Power Up Beeper Power Up Beeper 
    Off - ScannerBEPPWR03-1
    *Power Up Beeper 
    On - ScannerBEPPWR13-1
    Beep on BEL 
    CharacterBeep on BEL On BELBEP13-1
    *Beep on BEL Off BELBEP03-1
    Beeper - Good Read  Off BEPBEP03-2
    *On BEPBEP13-2
    Beeper Volume - 
    Good ReadOff BEPLVL03-2
    Low BEPLVL13-2
    Medium BEPLVL23-2
    *High BEPLVL33-2 SelectionSetting
    * Indicates default
    Serial Command
    # Indicates a numeric 
    entryPage 
    						
    							9 - 18
    Beeper Pitch - Good 
    Read  (Frequency)Low (1600 Hz) BEPFQ116003-3
    *Medium (2350 Hz) BEPFQ123503-3
    High (4200 Hz) BEPFQ142003-3
    Beeper - Transmit 
    Order*Before 
    TransmissionBEPWHN13-3
    After Transmission BEPWHN23-3
    Beeper Pitch - Error 
    (Frequency)*Razz (100 Hz)  BEPFQ21003-3
    Medium (2000 Hz) BEPFQ220003-3
    High (4200 Hz) BEPFQ242003-3
    Beeper Duration - 
    Good Read*Normal Beep BEPBIP03-4
    Short Beep BEPBIP13-4
    Number of Beeps - 
    Good Read Range 1 - 9 (*1) BEPRPT#3-4
    Number of Beeps - 
    Error Range 1 - 9 (*1) BEPERR#3-5 SelectionSetting
    * Indicates default
    Serial Command
    # Indicates a numeric 
    entryPage 
    						
    							9 - 19
    LED Settings *Red LED Off LEDFN103-6
    Green LED Off LEDFN203-6
    Red LED On with 
    Good ScanLEDFN113-6
    *Green LED On with 
    Good ScanLEDFN213-6
    Red LED On with 
    LaserLEDFN123-6
    Green LED On with 
    LaserLEDFN223-6
    Red LED On when 
    CodeGate DisabledLEDFN143-6
    Green LED On 
    when CodeGate 
    DisabledLEDFN243-6
    Red LED On when 
    In-StandLEDFN183-6
    Green LED On 
    when In-StandLEDFN283-6
    Red LED On with 
    CTSLEDFN11283-7
    Green LED On with 
    CTSLEDFN21283-7
    LED Brightness Red Off LEDIN103-7
    Green Off LEDIN203-7
    Red Low LEDIN113-7
    Green Low LEDIN213-7
    Red Medium LEDIN123-7
    Green Medium LEDIN223-7
    *Red High LEDIN133-7
    *Green High LEDIN233-7 SelectionSetting
    * Indicates default
    Serial Command
    # Indicates a numeric 
    entryPage 
    						
    							9 - 20
    In-Stand and Out-of-
    Stand SettingsIn-Stand Defaults AISDFT3-8
    Out-of-Stand 
    DefaultsAOSDFT3-8
    Presentation Mode 
    Out-of-StandPA P P M 13-9
    Presentation Mode 
    with CodeGate Out-
    of-StandPA P P M 23-9
    Manual Activation 
    Mode Off In-StandAISMEN03-9
    *Manual Activation 
    Mode On In-StandAISMEN13-9
    Manual Activation 
    Mode Off Out-of-
    StandAOSMEN03-9
    *Manual Activation 
    Mode On Out-of-
    StandAOSMEN13-9
    Do Not End Manual 
    Activation After 
    Good Read In-StandAISMGD03-10
    *End Manual 
    Activation After 
    Good Read In-StandAISMGD13-10
    Do Not End Manual 
    Activation After 
    Good Read Out-of-
    StandAOSMGD03-10
    *End Manual 
    Activation After 
    Good Read Out-of-
    StandAOSMGD13-10
    Laser Timeout - 
    Trigger Hold In-
    Stand
    (Range 1 - 65525) 
    *5000 msAISMPT#####3-10 SelectionSetting
    * Indicates default
    Serial Command
    # Indicates a numeric 
    entryPage 
    						
    							9 - 21
    In-Stand and Out-of-
    Stand Settings 
    (continued)Laser Timeout - 
    Trigger Release In-
    Stand
    (Range 1 - 65525) 
    *0 msAISMRT#####3-10
    Laser Timeout - 
    Trigger Hold Out-of-
    Stand
    (Range 1 - 65525) 
    *30000 msAOSMPT#####3-10
    Laser Timeout - 
    Trigger Release Out-
    of-Stand
    (Range 1 - 65525) 
    *0 msAOSMRT#####3-10
    *CodeGate Off In-
    StandAISCGD03-11
    CodeGate On In-
    StandAISCGD13-11
    CodeGate Off Out-
    of-StandAOSCGD03-11
    *CodeGate On Out-
    of-StandAOSCGD13-11
    Object Detection 
    Mode Off In-StandAISOEN03-11
    Object Detection 
    Mode On Out-of-
    StandAOSOEN13-11
    *Object Detection 
    Mode Off Out-of-
    StandAOSOEN03-11
    *Object Detection 
    Mode On In-StandAISOEN13-11
    Do Not End Object 
    Detection After 
    Good Read In-StandAISOGD03-12 SelectionSetting
    * Indicates default
    Serial Command
    # Indicates a numeric 
    entryPage 
    						
    							9 - 22
    In-Stand and Out-of-
    Stand Settings 
    (continued)*End Object 
    Detection After 
    Good Read In-StandAISOGD13-12
    Do Not End Object 
    Detection After 
    Good Read Out-of-
    StandAOSOGD03-12
    *End Object 
    Detection After 
    Good Read Out-of-
    StandAOSOGD13-12
    Object Detection 
    Laser Timeout In-
    Stand
    (Range 1 - 65525) 
    *5000 msAISODT#####3-12
    Object Detection 
    Laser Timeout Out-
    of-Stand
    (Range 1 - 65525) 
    *5000 msAOSODT#####3-12
    *Object Detection 
    Distance - Short In-
    StandAISRNG23-13
    Object Detection 
    Distance - Long In-
    StandAISRNG13-13
    Object Detection 
    Distance - Short 
    Out-of-StandAOSRNG23-13
    *Object Detection 
    Distance - Long Out-
    of-StandAOSRNG13-13 SelectionSetting
    * Indicates default
    Serial Command
    # Indicates a numeric 
    entryPage 
    						
    							9 - 23
    Character Activation 
    Mode*Off HSTCEN03-13
    On HSTCEN13-13
    Activation Character HSTACH##3-14
    Do Not End 
    Character Activation 
    After Good ReadHSTCGD03-14
    *End Character 
    Activation After 
    Good ReadHSTCGD13-14
    Character Activation 
    Laser Timeout 
    (Range 1 - 65525) 
    *5000 msHSTCDT#####3-14
    Character 
    Deactivation Mode*Off HSTDEN03-15
    On HSTDEN13-15
    Deactivation 
    CharacterHSTDCH##3-15
    Reread Delay Short (500 ms) DLYRRD5003-16
    *Medium (750 ms) DLYRRD7503-16
    Long (1000 ms) DLYRRD10003-16
    Extra Long (2000 
    ms)DLYRRD20003-16
    User-Specified 
    Reread DelayRange 0 - 30,000 
    msDLYRRD#####3-16
    Output Sequence 
    EditorEnter Sequence SEQBLK3-19
    Default Sequence SEQDFT3-19
    Sequence Timeout (Range 1 - 65535) 
    *5000 msSEQDLY#####3-19
    Sequence Match 
    Beeper*On SEQBEP13-20
    Off SEQBEP03-20
    Partial Sequence Transmit Partial 
    SequenceSEQTTS13-20
    *Discard Partial 
    SequenceSEQTTS03-20 SelectionSetting
    * Indicates default
    Serial Command
    # Indicates a numeric 
    entryPage 
    						
    							9 - 24
    Require Output 
    SequenceRequired SEQ_EN23-21
    On/Not Required SEQ_EN13-21
    *Off SEQ_EN03-21
    No Read On SHWNRD13-21
    *Off SHWNRD03-21
    Prefix/Suffix Selections
    Add CR Suffix to All Symbologies VSUFCR4-3
    Prefix Add Prefix PREBK2##4-3
    Clear One Prefix PRECL24-3
    Clear All Prefixes PRECA24-3
    Suffix Add Suffix SUFBK2##4-4
    Clear One Suffix SUFCL24-4
    Clear All Suffixes SUFCA24-4
    Transmit Alternate 
    Extended ASCII 
    Characters*Transmit Alternate 
    Extended ASCIiKBDEXT04-4
    Transmit Normal 
    Extended ASCIiKBDEXT14-4
    Function Code 
    Transmit*Enable RMVFNC04-6
    Disable RMVFNC14-6
    Communication 
    Check Character*None HSTXRC04-6
    LRC Starts on 1st 
    CharacterHSTXRC14-6
    LRC Starts on 2nd 
    CharacterHSTXRC24-6
    CRC HSTXRC34-6
    Intercharacter Delay Range 0 - 1000 
    (5ms increments)DLYCHR##4-7
    User Specified 
    Intercharacter DelayDelay Length
    0 - 1000 (5ms 
    increments)DLYCRX##4-8
    Character to Trigger 
    DelayDLY_XX##4-8 SelectionSetting
    * Indicates default
    Serial Command
    # Indicates a numeric 
    entryPage 
    						
    							9 - 25
    Interfunction Delay Range 0 - 1000 
    (5ms increments)DLYFNC##4-8
    Intermessage Delay Range 0 - 1000 
    (5ms increments)DLYMSG##4-9
    Data Formatter Selections
    Data Format Editor *Default Data 
    Format (None)DFMDF35-1
    Enter Data Format DFMBK3##5-2
    Clear One Data 
    For matDFMCL35-3
    Clear All Data 
    For matsDFMCA35-3
    Data Formatter Data Formatter Off DFM_EN05-8
    *Data Formatter On,
    Not Required, 
    Keep Prefix/SuffixDFM_EN15-9
    Data Format 
    Required,
    Keep Prefix/SuffixDFM_EN25-9
    Data Formatter On,
    Not Required, 
    Drop Prefix/SuffixDFM_EN35-9
    Data Format 
    Required,
    Drop Prefix/SuffixDFM_EN45-9
    Data Format Non-
    Match Error Tone*Data Format Non-
    Match Error Tone 
    OnDFMDEC05-10
    Data Format Non-
    Match Error Tone 
    OffDFMDEC15-10 SelectionSetting
    * Indicates default
    Serial Command
    # Indicates a numeric 
    entryPage 
    						
    							9 - 26
    Primary/Alternate 
    Data FormatsPrimary Data 
    For matALTFNM05-10
    Data Format 1 ALTFNM15-10
    Data Format 2 ALTFNM25-10
    Data Format 3 ALTFNM35-10
    Single Scan Data 
    Format ChangeSingle Scan-Primary 
    Data FormatVSAF_05-11
    Single Scan-Data 
    Format 1VSAF_15-11
    Single Scan-Data 
    Format 2VSAF_25-11
    Single Scan-Data 
    Format 3VSAF_35-11
    Symbologies
    All Symbologies All Symbologies Off ALLENA06-1
    All Symbologies On ALLENA16-1
    Codabar Default All Codabar 
    SettingsCBRDFT6-3
    Off CBRENA06-3
    *On CBRENA16-3
    Codabar Start/Stop 
    Char.*Don’t Transmit CBRSSX06-3
    Transmit CBRSSX16-3 SelectionSetting
    * Indicates default
    Serial Command
    # Indicates a numeric 
    entryPage 
    						
    All Honeywell manuals Comments (0)