Page 361
Parameter Settings for Keypad Entry Appendix C C–4 A034 Multi-speed 14 setting0.00 0.00 0.00 A035 Multi-speed 15 setting 0.00 0.00 0.00 A038 Jog frequency setting 1.00 1.00 1.00 A039 Jog stop mode 00 00 00 A041 Torque boost method selection 00 00 00 A241 Torque boost method selection, 2nd motor 00 00 00 A042 Manual torque boost value 1.0 1.0 1.0 A242 Manual torque boost value, 2nd motor 1.0 1.0 1.0 A342 Manual torque boost value, 3rd motor 1.0 1.0 1.0 A043 Manual torque boost frequency adjustment 5.0 5.0...
Page 362
SJ7002 Inverter Appendix C C–5 A064, A066, A068Jump (hysteresis) frequency width setting 0.50 0.50 0.50 A069 Acceleration stop frequency setting 0.00 0.00 0.00 A070 Acceleration stop time frequency setting 0.0 0.0 0.0 A071 PID Function Enable 00 00 00 A072 PID proportional gain 1.0 1.0 1.0 A073 PID integral time constant 1.0 1.0 1.0 A074 PID derivative gain 0.0 0.0 0.0 A075 PV scale conversion 1.00 1.00 1.00 A076 PV source setting 00 00 00 A077 Reverse PID action 00 00 00 A078 PID output limit 0.00...
Page 363
Parameter Settings for Keypad Entry Appendix C C–6 A105 [OI]–[L] input start frequency enable01 01 01 A111 [O2]–[L] input active range start frequency 0.00 0.00 0.00 A112 [O2]–[L] input active range end frequency 0.00 0.00 0.00 A113 [O2]–[L] input active range start voltage –100. –100. –100. A114 [O2]–[L] input active range end voltage 100. 100. 100. A131 Acceleration curve constants setting 02 02 02 A132 Deceleration curve constants setting 02 02 02 A141 A input select for calculate function 02 02 02...
Page 364
SJ7002 Inverter Appendix C C–7 Fine Tuning Functions “B” Group ParametersDefault Setting User Setting Func. CodeNameFEF2, FE2 (Europe)FU2, FU2 (U.S.A.)FF2, F2 (Japan) B001 Selection of restart mode 00 00 00 B002 Allowable under-voltage power failure time 1.0 1.0 1.0 B003 Retry wait time before motor restart 1.0 1.0 1.0 B004 Instantaneous power failure / under-voltage trip alarm enable 00 00 00 B005 Number of restarts on power failure / under-voltage trip events 00 00 00 B006 Phase loss detection...
Page 365
Parameter Settings for Keypad Entry Appendix C C–8 B029 Scan time constant for active freq. matching 0.50 0.50 0.50 B030 Restart freq. select for active freq. matching 00 00 00 B031 Software lock mode selection 01 01 01 B034 Run/power-on warning time 0. 0. 0. B035 Rotational direction restriction 00 00 00 B036 Reduced voltage start selection 06 06 06 B037 Function code display restriction 04 04 04 B038 Initial display selection 01 01 01 B039 Automatic user parameter function enable 00 00 00 B040 Torque...
Page 366
SJ7002 Inverter Appendix C C–9 B068 [O2] input hysteresis width of window comparator 000 B070 [O] input disconnect threshold 255(no) 255(no) 255(no) B071 [OI] input disconnect threshold 255(no) 255(no) 255(no) B072 [O2] input disconnect threshold 127(no) 127(no) 127(no) B078 Clear cumulative input power data 00 00 00 B079 Cumulative input power display gain setting 111 B082 Start frequency adjustment 0.50 0.50 0.50 B083 Carrier frequency setting 3.0 2.1 1.9 3.0 2.1 1.93.0 2.1 1.9 B084 Initialization mode...
Page 367
Parameter Settings for Keypad Entry Appendix C C–10 Intelligent Terminal Functions B120 Brake Control Enable00 00 00 B121 Brake Wait Time for Release 0.00 0.00 0.00 B122 Brake Wait Time for Acceleration 0.00 0.00 0.00 B123 Brake Wait Time for Stopping 0.00 0.00 0.00 B124 Brake Wait Time for Confirmation 0.00 0.00 0.00 B125 Brake Release Frequency Setting 0.00 0.00 0.00 B126 Brake Release Current Setting Rated current for each inverter B127 Braking frequency 0.00 0.00 0.00 B130 Over-voltage LADSTOP...
Page 368
SJ7002 Inverter Appendix C C–11 C019 Terminal [FW] active state00 00 00 C021 Terminal [11] function 01 01 01 C022 Terminal [12] function 00 00 00 C023 Terminal [13] function 03 03 03 C024 Terminal [14] function 07 07 07 C025 Terminal [15] function 08 08 08 C026 Alarm relay terminal function 05 05 05 C027 [FM] signal selection 00 00 00 C028 [AM] signal selection 00 00 00 C029 [AMI] signal selection 00 00 00 C030 Digital current monitor refe rence valueRated current x 1.0 C031 Terminal [11] active state 00...
Page 369
Parameter Settings for Keypad Entry Appendix C C–12 C071 Communication speed selection04 04 04 C072 Node allocation 1. 1. 1. C073 Communication data length selection 77 7 C074 Communication parity selection 00 00 00 C075 Communication stop bit selection 11 1 C076 Action upon communication error selection 02 02 02 C077 Communication timeout before trip 0.00 0.00 0.00 C078 Communication wait time 0. 0. 0. C079 Communication protocol select 00 00 00 C081 [O] input span calibration Factory set Factory set...
Page 370
SJ7002 Inverter Appendix C C–13 C137 Terminal [14] OFF-delay time0.0 0.0 0.0 C138 Terminal [15] ON-delay time 0.0 0.0 0.0 C139 Terminal [15] OFF-delay time 0.0 0.0 0.0 C140 Relay output ON-delay time 0.0 0.0 0.0 C141 Relay output OFF-delay time 0.0 0.0 0.0 C142 Logic output 1 function A 00 00 00 C143 Logic output 1 function B 00 00 00 C144 Logic output 1 operator 00 00 00 C145 Logic output 2 function A 00 00 00 C146 Logic output 2 function B 00 00 00 C147 Logic output 2 operator 00 00 00 C148 Logic...