ModBus Data Listing
Appendix B
B–68
H034 H Auto constant J, 1st motor R/W 0.001 to 9.999, 10.00 to 99.99, 
100.0 to 999.9, 
1000 to 9999.152Ch 05420 1 to 
99990000.001
H034 L R/W 152Dh 05421
H234 H Auto constant J, 1st motor R/W 0.001 to 9.999,  10.00 to 99.99, 
100.0 to 999.9, 
1000 to 9999.252Ch 09516 1 to 
99990000.001
H234 L R/W 252Dh 09517
— (Reserved) — — 152Eh  to 
153Ch 05422 
to 
05436 ——
H050 — PI proportional gain for 1st  motor R/W 0.0 to 999.9,  1000. 153Dh 05437 0 to 10000 0.1 %
H250 — PI...

Page 352

SJ7002 Inverter
Appendix B
B–69
Use the codes in the table below to return parameters for H003 and H203 (motor capacity 
selection).
H073 — Gain switching time R/W 0. to 999. (milliseconds) 155 4h 05460 0 to 9999 1 msec.
— (Reserved) — — 1555h  to 
1600h 05461 
to 
05632 ——
Holding Registers, “H” Group Motor Constants Functions
Func. CodeNameR/WDescription
Network Data
RegisterRangeRes.hexdec.
Code Data0001020304050607080910
Japan or U.S.A. mode 
(B085 = 00 or 02) 0.2 kW — 0.4 — 0.75 — 1.5 2.2 — 3.7 —
EU...

Page 353

ModBus Data Listing
Appendix B
B–70
Holding Registers, “P” Group Expansion Card Functions
Func. CodeNameR/WDescription
Network Data
RegisterRangeRes.hexdec.
P001 — Operation mode on expan- sion card 1 error R/W 00 ..Trip (stop motor)
01 ..Continuous operation 1601h 05633 0, 1 —
P002 — Operation mode on expan- sion card 2 error R/W 00 ..Trip (stop motor)
01 ..Continuous operation 1602h 05634 0, 1 —
— (Reserved) — — 1603h  to 
160Ah 05635 
to 
05642 ——
P011 — Encoder pulse-per-revolu- tion (PPR) setting...

Page 354

SJ7002 Inverter
Appendix B
B–71
P028 — Numerator of motor gear ratio R/W 0. to 9999. 161Ch 05660 1 to 9999 1
P029 — Denominator of motor gear  ratio R/W 1 to 9999 161Dh 05661 1 to 9999 1
— (Reserved) — — 161Eh 05662 — —
P031 — Accel/decel time input  selection R/W 00 . Inverter
01 . Expansion card 1
02 . Expansion card 2 161Fh 05663 0, 1, 2 —
P032 — Positioning command  input selection R/W 00 . Inverter
01 . Expansion card 1
02 . Expansion card 2 1620h 05664 0, 1, 2 —
P033 — Torque command input...

Page 355

ModBus Data Listing
Appendix B
B–72
P047 — DeviceNet polled I/O: Input instance number R/W 70, 71, 101 1631h 05681 70, 71, 
101—
P048 — Inverter action on  DeviceNet idle mode R/W 00 ..Trip
01 ..Decelerate and trip
02 ..Hold last speed
03 ..Free run stop
04 ..Decelerate and stop 1632h 05682 0 to 4 —
P049 — Motor poles setting for  RPM R/W 00 to 38 (even numbers only) 1633h 05683 0 to 19 1 = 
2poles
— — (Reserved) — — 1634h  to 
1638h 05684 
to 
05688 ——
P055 — Pulse train frequency span R/W 1.0 to 50.0...

Page 356

SJ7002 Inverter
Appendix B
B–73
P070 — Low speed homing frequency R/W 0.00 to 10.00 (Hz) 1650h 05712 0 to 1000 0.01 Hz
P071 — High speed homing  frequency R/W 0.00 to 99.99 / 100.0 to 
maximum frequency setting, 
1st motor (Hz) 1651h 05713 0 to 40000 0.01 Hz
P072 H Forward position range  setting R/W 0 to 536870912 (when P012 
= 02), 0 to 2147483647 
(when P013 = 03) (upper 
four digits) 1652h 05714 See 
descrip-
tion 1
P072 L R/W 1653h 05715
P073 H Reverse position range R/W 0 to 536870912 (when P012  =...

Page 357

ModBus Data Listing
Appendix B
B–74
P116 — Easy sequence parameter (U16) R/W 0. to 9999., 1000 to 6553 
(10000 to 65535) 1676h 05750 0 to 65530 1
P117 — Easy sequence parameter  (U17) R/W 0. to 9999., 1000 to 6553 
(10000 to 65535) 1677h 05751 0 to 65530 1
P118 — Easy sequence parameter  (U18) R/W 0. to 9999., 1000 to 6553 
(10000 to 65535) 1678h 05752 0 to 65530 1
P119 — Easy sequence parameter  (U19) R/W 0. to 9999., 1000 to 6553 
(10000 to 65535) 1679h 05753 0 to 65530 1
P120 — Easy sequence parameter...

Page 358

Drive Parameter 
Settings Tables
In This Appendix....page
— Introduction.......................................................................................   2
— Parameter Settings for Keypad Entry...............................................   2
C

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]  

Page 359

Introduction
Appendix C
C–2
Introduction
This appendix lists the user-programmable parameters for the SJ7002 series inverters and the 
default values for European, U. S. and Japanese product types. The right-most column of the 
tables is blank so you can record values you have  changed from the default. This involves just a 
few parameters for most applications.
Parameter Settings for Keypad Entry
SJ7002 series inverters provide many functions an d parameters that can be configured by the 
user. We...

Page 360

SJ7002 Inverter
Appendix C
C–3
Standard 
Functions
“A” Group ParametersDefault Setting
User 
Setting
Func.  CodeNameFEF2, FE2  (Europe)FU2, FU2 (U.S.A.)FF2, F2 (Japan)
A001 Frequency source setting 01 01 02
A002 Run command source setting 01 01 02
A003 Base frequency setting 50. 60. 60.
A203 Base frequency setting, 2nd motor 50. 60. 60.
A303 Base frequency setting, 3rd motor 50. 60. 60.
A004 Maximum frequency setting 50. 60. 60.
A204 Maximum frequency setting, 2nd motor 50. 60. 60.
A304 Maximum frequency...