This Use & Care Guide is t o be only us ed for the mechanical c ontrol 5,000 B TU models. S ome mechanical 5,000 B TU models ma y have an additional lett er aft er the model number . NO.0010559927 C e guide d’utilisation et d’ entretien ne doit êtr e utilisé qu’avec les modèles de 5,000 BTU à c ommande mécanique. S ur c ertains modèles mécaniques 5,000 BTU , le numér o de modèle peut êtr e suivi dune lettr e. Esta Guía de us o y cuidado se debe usar únicament e para los modelo s 5,000 BTU de c ontr ol mecánic o. Alguno s modelo s mecánic os 5,000 B TU pueden t ener una letra adicional después del númer o de modelo . HWF05XCL User & Car e Guide Guide dutilisation et dentr etien Guía de uso y cuidado Room Air Conditioner Climatiseur individuel Air e ac ondicionado de uso domés tico FAN ONL YMIN COOL MAX COOL10 1 2 3 4 5 6 7 8 9 LOW HI ON OFF W ait 3 Minutes Before Restarting SPEED POWER Design ma y vary by model number .La configuration peut varier s elon le numér o de modèle. El dis eño puede variar c onforme al númer o de modelo
TABLE OF CONTENT S PRODUC T RE GIS TRA TION Thank you for purchasing our Haier product. This easy-to-use manual will guide you in getting the best use of your product. Remember to record the model and serial numbers. They are on a label on the side of y our unit. Model number Serial number Date of purchase Staple your receipt to your manual. You will need it to obtain warranty service. SAFETY INFORMA TION........................................................................\ ..................................... 2 Important Safety Pr ecautions ........................................................................\ ............................ 2 Oper ational Safety & W arnings ........................................................................\ .......................... 4 INS TALL ATION REQUIREMENT S ........................................................................\ ..................... 5 T ools and Parts ........................................................................\ .................................................... 5 L ocation Requir ements ........................................................................\ ...................................... 6 Electrical Requir ements ........................................................................\ ................................. 7-9 HO W TO INS TALL ........................................................................\ ............................................ 10 Unpacking the Air Conditioner ........................................................................\ ................... 10-11 Pr eparing the Air Conditioner ........................................................................\ .................... 10-11 Pr eparing the Windo w ........................................................................\ ...................................... 12 C ompleting the Installation ........................................................................\ .............................. 13 USING YOUR AIR CONDITIONER ........................................................................\ ................... 14 S tarting the Air Conditioner ........................................................................\ ....................... 14-15 Changing the Air Direction ........................................................................\ ............................... 15 C ARING FOR YOUR AIR CONDITIONER ........................................................................\ ........ 16 Cleaning the Air Filter ........................................................................\ ....................................... 16 Cleaning the Front Panel ........................................................................\ .................................. 17 Cust omer Service ........................................................................\ ............................................. 17 TR OUBLE SHOOTING ........................................................................\ ...................................... 19 LIMITED WARRANTY ........................................................................\ ....................................... 20 ENGLISH Normal Sounds of an Air Conditioner ........................................................................\ .............. 18
1. e s U this air conditioner only for its intended application as described in this Use & Car e Guide. 2. This air conditioner must be properl y installed and use the corr ect wall outlet that matches with the air conditioner’s power suppl y cor d in acc ordance with the Installation Section of this Use & Car e Guide before it is oper ated. 3. r e v e N unplug the air conditioner by pulling on the power suppl y cor d. Al way s grip the plug firmly and pull straight out from the wall outlet. 4. Replace the power suppl y cor d immediatel y if it bec omes damaged in an y w ay. A ne w po wer suppl y cor d must be pur chased from the air conditioner manuf acturer and installed by a qualified technician. DO NOT use a po wer suppl y cor d that is crack ed, split, cut, or damaged anywher e along its length or either at the plug end or connect or end. 5. T urn off the air c onditioner and unplug it from the wall outlet before perf orming any cleaning or maintenance. 6. o D no t st or e or use combustible or flammable materials or liquids on or near the air conditioner. 7. f I the wall outlet configur ation does not match the plug configur ation on the air conditioner , the wall outlet must be changed by a qualified electrician. PA GE 2 SAFETY INFORMA TION THE INFORMA TION IN THIS USE & CARE GUIDE MUST BE FOLL OWED TO MINIMIZE THE RISK OF PER SONAL INJURY, FIRE, ELEC TRIC SHOCK OR OTHER UNSAFE CONDITIONS. THE INSTRUC TIONS IN THIS USE & CARE GUIDE ARE NOT MEANT T O INCL UDE EVER Y PO SSIBLE CONDITION OR SITU ATION THAT MA Y OCC UR. USE CAUTION AND CARE WHEN INSTALLING, OPERATING AND CLEANING THE AIR CONDITIONER. W ARNING IMPOR TANT SAFETY PRECAUTIONS ENGLISH
SAFETY INFORMA TION PAGE 3 8. This air conditioner contains R410a refriger ant and requir es certified technicians to use the proper equipment, tools and safety standar ds that ar e appr oved for this refriger ant. Use only equipment certified for R410a r efriger ant. In addition, under feder al law, all refriger ant must be properl y r emoved For responsible disposal of the product please contact your local municipality for additional recycling options in your area. fr om the air conditioner prior to its disposal. READ AND FOLL OW THE S AFETY INSTRUC TIONS CAREFULL Y. SAVE THESE INS TRUC TIONS IMPOR TANT SAFETY PRECAUTIONS ENGLISH
ENGLISH OPERATIONAL SAFETY & WARNING S 1. This air conditioner contains no consumer serviceable parts. If you have pr oblems or questions regar ding the oper ation of your air conditioner al w ay s call Haier Customer Service: 1-877-337-3639. 2. e B sur e that the air conditioner is pr operl y and secur ely installed in the windo w acc ording to the installation instructions included in this Use & Car e Guide. 3. DO NOT drill any holes in the base or sides of the air conditioner. 4. O D NO T place finger s or objects in the air dischar ge or air intak e in the fr ont of the air conditioner. 5. O D NO T oper ate the air conditioner with a pr otective cover on the outside section. 6. O D NO T block the air dischar ge or air intak e ar eas on the front panel. 7. O D NO T block the side louver s on the outside of the air conditioner. 8. O D NO T place any objects either on the indoor or outdoor sections of the air conditioner. 9. Oper ate the air c onditioner with the air filter installed. 10. Keep this Use & Car e Guide, carton and packing material for fut ure use in removing, storing and reinstalling the air conditioner. PA GE 4 SAFETY INFORMA TION
ENGLISH TOOL S AND PARTS Read and follo w the instructions provided with any tools listed here. TOOL S NEEDED PAR TS SUPPLIED: Check that all parts for your specific air conditioner are included in the parts package. NO TE: If parts are missing, call Haier Customer Service: 1-877-337-3639. Phillips head screw driver Scissor s Level T ape measur e Drill and 1/8” bit Pencil IMA GE PART 5,000 BTU Top channel1 Foam seal1 2 Windo w lock brack et1 3/8 self-tapping screw s3 1 wood screw s9 Side curtains2 Side curtain frames2 INSTALL ATION REQUIREMENT S PAGE 5 Side brackets
ENGLISHPAGE 6 INSTALL ATION REQUIREMENT S IMPORTANT : e v r e s b O all governing codes and ordinances. Check the location where the air c onditioner will be installed. Make sur e you have every thing necessary for corr ect installation. THE LOC ATION SHOULD PROVIDE: • A gr ounded electrical outlet within 6 ft. (183 cm) of wher e the power suppl y cor d exits the air c onditioner , for models: HWF05XCL NO TE: o D no t use an extension cor d, plug adapter , sur ge protect or or multi-outlet adapter. • Fr ee movement of air in the room to be cooled. • A lar ge enough window opening for the air conditioner. (See Fig.2) • T he air conditioner must not be installed in a thr ough-the-w all sleeve or in a w all. It can only be installed in a double-hung window. NO TE: T he outside cabinet louvers and air discharge must not be obstructed by bushes, tr ees , etc. Air must be able to pass freel y thr ough the cabinet louver s. (S ee Fig.1) WINDO W INS TALL ATION LOC ATION REQUIREMENT S CABINE T LOUVER S Fig. 1 AIR DISCHARGE Window opening measurements: (See Fig. 2) HWF05XCL A. Width Min/Max 22-36 B. Height Min 13-3/8 Fig. 2 A-WIDTH B-HEIGHT
ENGLISH 1. O D NO T cut or remove the grounding prong on the attached power suppl y cor d. Doing so ma y cause sparks or fire, and voids all warr anties. For safety purposes the air conditioner must be pr operl y gr ounded. 2. To avoid a fir e ha zar d or possible electric shock, DO NOT use an adapter plug, extension cor d, sur ge protect ors, or multi-outlet adapters with the air conditioner. 3. The power suppl y cor d is equipped with a 3-pr ong plug which mates with a standar d 115 volt w all outlet to minimi ze the possibilit y of electrical shock from this air conditioner. 4. The power suppl y cor d includes a leak age current detection interrupter device (LCDI). A RE SET and TEST but ton are on the plug case. The device should be tested on a periodic basis by pressing the TEST but ton and then the RESET but ton while it is plugged into the wall outlet. If the TEST but ton does not trip or the RESET will not sta y engaged, do not use the air c onditioner and contact a qualified service technician. 5. e v a H the wall outlet and circuit inspected by a qualified electrician to ensur e that the wall outlet is pr operl y gr ounded. 6. f I ther e is a 2-pr ong wall outlet present and not a 3-pr ong wall outlet, it is the responsibilit y of the user to have it replaced with a pr operl y gr ounded 3-prong outlet. 7. The air conditioner should alw ay s be plugged into a dedicated electrical outlet which has a voltage rating that matches the serial label on the side of the air conditioner. 8. The electrical ratings for y our air conditioner are listed on the Model/Serial Number label. The Model/Serial Number label is located on the side of the air conditioner cabinet. 9. Specific electrical requir ements are listed in the chart below. Follo w the requir ements for the t ype of plug on the power suppl y cor d. ELEC TRICAL SAFE TY and WARNING S WARNING INSTALL ATION REQUIREMENT S PAGE 7 ELE CTRIC AL REQUIREMENT S POWER SUPPL Y CORD Wiring Requir ements • 115-Volt (103.5 min. to 126.5 max.) • 15- Amp time-dela y gr ounded fuse or circuit break er • Use on single outlet circuit only.
ENGLISHPAGE 8 INSTALL ATION REQUIREMENT S REQUIR ED GR OUNDING METHOD (S ee Fig.3) T his air conditioner must be grounded. This air conditioner is equipped with a po wer suppl y cor d that has a 3 pr ong grounding plug. The power suppl y c or d must be plugged into a mating, grounded 3 pr ong outlet, and grounded in acc ordance with all local codes and ordinances. If a mating outlet is no t available, it is the cust omer’s responsibilit y to contact a qualified electrician and ensur e that a pr operl y gr ounded 3 pr ong outlet is installed. PO WER SUPPL Y CORD (S ee Fig.4) NO TE: Y our air conditioners plug may differ slightl y in appear ance from the one shown. A. R eset button B. T est button T his room air c onditioner is equipped with an a leak age current detection interrupter (LCDI) po wer suppl y cor d requir ed by UL. This power suppl y cor d contains a curr ent detection device. If the power suppl y cor d is crushed, this device will detect current leak age and power will be disc onnected from the air conditioner. If this power suppl y cor d is damaged, it canno t be r epair ed and must be replaced with a cor d from the product manuf acturer. If the power suppl y c or d is damaged call Haier Customer Service: 1-877-337-3639. ELECTRIC AL REQUIREMENT S cont. RESET TESTA B Fig. 4 Fig. 3