Page 721

5210TL-130200-10012.If C register is 00, 02, 03, 05, 06, or 07, complete the following
steps:
-Force CIPNCIPIDVCIP 00s - FORCE CIP CA X YY OS.
x=PEC 
#3, Always 0 orFORCE VPLC (PEC GRP SLOT)
W=CARD 30 -15
-Remove and replace CIPNCIPIDVCIP, FB -17235
A/17236-A in identified slot (check strapping).
-Force CIPNCIPIDVCIPNP20 INS - FORCE CIP CA X YY IS.
x=
PEC#, Always 0 orFORCE VPLC (PEC GRP SLOT)
W=CARD #O -15
3.If PCB replaced is a VCIP/DVCIP, FB-17235-A/17236-A, force
download the PCB as follows:...

Page 722

TL130200-1001
FAULT CODE 321FAULT CODE 
- 32
II1FORCE 
CIP/VCIP/DVCIP
b CARD OS: FORCE CIP CA X
w OS.
$rFORCE CIPNCIPIDVCIP
CARD.
CIP, FB-17225VCIP, FB-17235
DVCIP, FB-17236
4
IFORCE CIPNCIPIDVCIP
CARD INS:FORCE CIP CA X YY IS.
x-YES
IDENTIFY DATA LINKS
ASSOCIATED WITH 
VCIP/DVCIP RELATIVE CARD NO.
NO
NO
NOREINSTALL ORIGINAL
VCIP, 
FB-I 7235 OR
DVCIP, FB-17236IDENTIFY MPB85,
rFB-17215ASSOCIATED WITH
PCMUS HOUSING
CIPNCIPIDVCIP
CARD
+POWER DOWN
SYSTEM
+R&R MPB85, 
FB-17215 PREVIOUSLY 
-
IDENTIFIED...

Page 723

TL-130200-1001Fault Code 33Description:
CIPNCIPIDVCIPThis fault indicates a failure in the Integrated/Digital
Port FailureFeaturephone cabling or CIPNCIPIDVCIP card.
5210
Register Data as System Prints:CECO CECO Fault 33 B C 
D E H L
00 00 00
00= Data Link Error
01= CIP Port Protocol Error
02= Port Sync Error
03= Port Enable Error
04 = CIP Other Port Errors
05= Test Failure
06 = Download Failure
07 = Port Recovery Errors
Fault Resolution Steps:
1.Identify and locate Featurephone associated with fault...

Page 724

TL-130200-1001
0637 =
Relative Cl Card No. 8
OB38 =
Relative Cl Card No. 9
0839 =
Relative Cl Card No. 10
063A =
Relative Cl Card No. 11
OB3B =
Relative Cl Card No. 12
OB3C =
Relative Cl Card No. 13
OB3D =Relative Cl Card No. 14
OB3E =Relative Cl Card No. 15
- Using the relative Cl card number, force the
CIP/VCIP/DVCIP 00s.Force 
CIPAJCIPIDVCIP 00s - FORCE CIP CA X YY OS.
x=PEC#, Always 0
YY=CARD #O-l 5
- Remove and replace CIPNCIPIDVCIP, FB-17235
A/l 7236-A in identified slot (check strapping).
Force...

Page 725

RUN SELF-TEST ON
FEATUREPHONE TEST
PHONE, DN XXXX, OR
TEST DN XXXX.TL-130200-1001
IDENTIFY ANY SID
ASSOCIATED WITHPREVIOUSLY DEFINEDDATA LINKS
RELATIVE CARD NO.
4ASSOCIATED WITH
FORCE DOWNLOADON 
VCIP/DVCIP:
FORCE DOWNLOADX YYY IN.
fREINSTALL ORIGINAL
VCIP, FB-17235, OR
DVCIP, FB-17236
IREINSTALL ORIGINAL
CIP, FB-17225 CARDIDENTIFY MPB85,
FB-17215ASSOCIATED WITH
PCMUS HOUSING
ClPNClPlDVClP CARD PCMUS ASSOCIATION
CIPNCIPIDVCIP PCB
VCIP/DVCIP RELATIVE
FEATUREPHONE
‘ZIP, FB-17225
VCIP, FB-17235
DVCIP,...

Page 726

TL-130200-1001Fault Code 36Description:
Change MDR SystemThis fault indicates that receiving a CRIB (Call Record
Clock FailureInformation Buffer) from the idle crib list failedThe indication isthat MDR failed to change its system clock after a request from a
user. If this happens, there were too many calls in progress to
handle the request.
M-l 50
Register Data as System Prints:CECO CECO Fault 36 B C D E H L
,xx,,xx,,xx,\xx/?

Page 727

TL-130200-1001Fault’Code 37Description:
System Warm StartFault Code 37 is generated every time a warm or cold start
occurs in the system. Register B in Fault Code 37 contains the
total count of warm starts which have occurred since the last
cold start. If Register B= 0, then a cold start has occurred.
Register C contains the threshold count for this fault. If register C
contains any value other than 0, the system has attempted a
warm start in 4 minutes or less since the last warm start. If
register C is...

Page 728

TL-130200-1001Fault Code 41Description:
FMS Disk ErrorThis fault indicates genera
M-l 52.I disk I/O errors.
Register Data as System Prints:CECO CECO Fault 41 B C D E H L
rRequest which failed
OE =Writing Out Data Base
14 =Writing Out 
HC/M
1D =Downloading F/P File
1F= Closing F/P File
Error CodeDCBDRB Start
FF 
=.SequenceAddress
TimeoutIndex(Low Byte)
(TCSIX)
Fault Resolution Steps:
1.Repeat the task that was being performed when fault
occurred. If fault recurs, continue.
2.If the C register value is FF,...

Page 729

TL-130200-1001. c-w-. VVIb -r. 
.REPEATTASK
JUST PERFORMED
+.
NO
* YESC=FF
FB-17220 IN 
Y/O7PSUPY FOR
NO
* YES
R&R FLOPPY
DISK DRIVE
52107187M-153 

Page 730

TL-130200-1001Fault Code 42Description:
Time Slot LockupFault Code 42 is generated when a time slot lockup is detected.When allocating a time slot, a check should be made to see if the
hardware ID is already in channel memory. If it is, then a time
slot is locked up. The old time slot is released before allocating
the new time slot.
Register Data as System Prints:CECO CECO Fault 42 B C D E H L
00 \xx y \xx 00 00
Hardware
IDTime Slot Call Store
NumberNumber
M-l 54
71875210 