TL-130200-1001File ManagementWhen loading the FMS files into the system, certain errors may System (FMS) Errorsbe received. For example,“FMS error 14” is received. This means that FILE D is not available for creation, for opening, or for seizure. Refer to Table 3.1 for status code and explanation. Table 3.1FMS StatusCode and Explanation EXPLANATIONfile is not open for output 52108187M-l 05
Page 682
TL-130200-1001Table 3.1FMS StatusCode and Explanation (Continued FMS STATUS CODEEXPLANATION 22Iwrite past physical EOF attempted 23seek past physical EOF attempted 24record sizes not equal 25files open on device 26FID not seized . 1 27] access is invalid 30device not ready 31device I/O error 32Idevice write protected 34not allowed on mounted disk 35no device attached 36device is private 40invalid commander number 126command awaiting executionM-l 06command executing 61875210
Page 683
SYSTEM MAINTENANCE GENERAL PRINCIPLES. . Preventive Maintenance System Voltage Checks System Operation Checks Spare Cards Quick Reference Chart 5210TL-130200-1001 4.0 Maintenance commands are input via the maintenance terminal to designate particular parts of the system hardware as “maintenance busy” so that system software will not try to use that hardware during system operation. Hardware is out of service when designated as maintenance busy. That piece of hardware becomes available for maintenance...
Page 684
TL-130200-1001Attendant Console4.6 The memory of each CEC provides an area called the fault Code Display Faultlog which records system faults. It records the last 32 faults detected. When a fault is detected, the ALARM LED on each Attendant Console flashes, indicating that a fault has occurred. Each console displays all faults reported in the fault log independently of the other consoles in the system. All of the faults listed on the fault log are displayed by repeated depressions of the ALARM...
Page 685
TL-130200-1001 Table 4.1Attendant Console Fault Log Decoding Summary-..FUNCTIONATENDANT CONSOLE STATIONS NUMBER DISPLAY FAULT TYPE SELECTED OPTIONAL DIGIT DIGIT 1DIGIT 2DIGIT 3 + DIGIT 4 CEC block-parity error CEC dynamic-memory failure CEC network read-after-write-error CEC-PEC common memory read-after-write-error CEC total communication failure CEC single communication failure CEC system network test error Preloading test failure Peripheral Equipment Complex (PEC) Network test error PEC directive test...
Page 686
TL-130200-1001Fault Code 00Description: Block Parity FailureWhen a program is loaded into the system, the CPU85 willgenerate block parity for each 256 bytes of instruction data and static data. This is done by an exclusive OR of the data table. Periodically, the CPU85 will recalculate the block parity andcompare it with the value calculated earlier (detect memory failures and data mutilation). . .Register Data as System Prints:CECO CECO Fault 00 B C D E H I Test FailureAddress of Faulty Byte IFailing I...
Page 687
TL-130200-1001 FAULT CODE 00 POWER DOWN SYSTEM1R&R Ml MB IN Y/O1 FB-17314 (Check Strapping) POWER UPAND RELOAD IIYESPOWER DOWN &REINSTALL ORIGINAL Ml MB CARD 1R&R MP85 IN Y/O2 FB-17213 (Check Strapping) 1 POWER UPAND RELOAD 1MONITOR PSUPY FOR“ASW” TO LIGHT f REPLACEBATTERY PACK FUSE 15210 8187M-111
Page 688
TL-130200-1001Fault Code 01Description: Dynamic RAM MemoryThe system tests dynamic memory. A block of five bytes is put into a temporary storage area. A series of test patterns is read into the area of memory being tested and then verified. The data is returned to its original location and the test advances to the next five bytes of dynamic memory (interrupts are disabled during this test). . . Register Data as System Prints:CECO CECO Fault 01 B C D E H L 00 00 \02 xx vTest Failure T Address of Faulty...
Page 689
: ITL-130200-1001 FAULT CODE 01 REMOVE BATTERY PACK FUSE cPOWER DOWN SYSTEM I 1 IR&R Ml MB IN Y/O1 FB-17314 (Check Strapping) 4 1POWER UPAND RELOAD YESPOWER DOWN &REINSTALL ORIGINAL Ml MB CARD 1R&R MPG16 IN Y/O2 FB-17213-BOA (Check Strapping) 1 POWER UPAND RELOAD 1 MONITOR PSUPY FOR “ASW” TO LIGHT5210 8l87M-113
Page 690
TL-130200-1001Fault Code 02Description: Control MemoryWhen a byte of data is written into the network memory, it is Read-After-Writeimmediately read back and verified. Failure . . .M-114 Register Data as System Prints:CECO CECO Fault 02 6 C D E H L O0 O0 Y xx =-I-- Data iAddress of WrittenFaulty ByteDataRead JFault Resolution Steps: 1.Power down - turn off main circuit breaker at rear of OMNI SI cabinet- 2.Remove and replace EPCMN in Y/09, FB-17217-A (check strapping). 3.Power up system. 4.Monitor PSUPY...