© 2016 Conquest Imaging 44 
 Copy/Restore the patient archive. 
 Copy/Restore the system configuration. 
The Copy/Restore system configuration feature enables the user to 
configure several units with identical presets, providing that the units 
have the same software version. 
There is no backup function for the images or reports. For long-term 
storage, images and reports should be moved to a USB HD or to a 
network shared folder using the Disk management...

Page 52

 GE Logiq E9/Vivid E9 Training Manual 
© 2016 Conquest Imaging 45 
6. Select a removable media or a shared network folder as 
destination. 
7. If the backup is to be stored to removable media, insert a 
dedicated media in the drive and select Start backup. If the media is 
not formatted a dialog will open:
 
Enter a label in the textbox for the media and click “Yes”. Only the 
following characters and signs can be used when labelling a media: A - 
Z, a - z, 0 - 9, “_” and “-”. Do not use more than eleven...

Page 53

 GE Logiq E9/Vivid E9 Training Manual 
© 2016 Conquest Imaging 46 
Restore Procedure for Vivid E9 
1. Press Utility/Config from the Touch panel and select the category 
Admin -> Restore tab. 
 
2. In the Restore tab select as needed: 
 Patient Archive to restore the patient archive. 
 System Configuration to restore all system settings and user 
presets. 
If restoring from removable media, make sure that the Restore from 
Source Device checkbox is selected and then select the appropriate 
Source...

Page 54

 GE Logiq E9/Vivid E9 Training Manual 
© 2016 Conquest Imaging 47 
 
Ensure that the correct source is selected and select OK. 
If connectivity configuration settings are restored the following 
information window is displayed: 
 
Select OK. 
The System shutdown window is displayed: 
 
Select OK. to shut down the system. 
4. Restart the system. 
5. If connectivity configuration settings have been restored, make 
sure to save the TCP/IP settings: 
 Select Config/Connectivity/TCPIP and select Save...

Page 55

 GE Logiq E9/Vivid E9 Training Manual 
© 2016 Conquest Imaging 48 
Backup Procedure for Logiq E9 
Depending on the system, you can use either a CD-R, DVD-R, USB 
Flash Drive, or USB Hard Disk for system backup/restore. 
System/Backup and Restore Preset Menu 
The backup and restore procedures described in this section are 
divided into two parts. The first describes procedures to backup and 
restore patient data. The second describes procedures to backup and 
restore system and user-defined...

Page 56

 GE Logiq E9/Vivid E9 Training Manual 
© 2016 Conquest Imaging 49 
Backup Preset Parameter Descriptions 
Patient Archive Select to back up patient data. 
Report Archive Select to back up report data. 
User Defined Configuration -Select to back up the user-defined 
configuration settings. 
Service Select to back up Service (iLinq and Network) settings. 
Backup Select to begin the backup. 
 
Media Preset Parameter DescriptionS 
Media Select media type to use for backup and restore 
 
EZMove Preset...

Page 57

 GE Logiq E9/Vivid E9 Training Manual 
© 2016 Conquest Imaging 50 
want to restore across multiple machines. Check the parameters you 
want to restore, insert media, and press Restore 
 
Detailed Restore of User Defined Preset Parameter Descriptions 
Imaging Presets Select to restore imaging presets. 
Connectivity Configuration Select to restore connectivity 
configurations. 
Measurement Configuration Select to restore measurement 
configurations. 
Comment/Body Pattern Libraries Select to restore comment...

Page 58

 GE Logiq E9/Vivid E9 Training Manual 
© 2016 Conquest Imaging 51 
 Insert the media into the media drive. On the Touch Panel, press 
Utility -> System. 
 On the monitor display, select Backup/Restore. The 
Backup/Restore screen is displayed. 
 In the Restore list, select Patient Archive. 
 In the Media field, select the media. 
 Select Restore. The system performs the restore. As it proceeds, 
status information is displayed on the Backup/Restore screen. 
Cleaning the Air Filters 
Clean the systems...

Page 59

 GE Logiq E9/Vivid E9 Training Manual 
© 2016 Conquest Imaging 52 
6.) Wipe off any oil or dust from the trackball housing, rollers, etc., 
using a cleaner or cotton bud. 
7.) Insert the trackball into the housing. 
8.) Place the Top Locking Plate including the Rubber Dust Filtering 
Ring back on the OP and lock it by rotating it clockwise. 
Test the Trackball: 
Power up the Vivid E9 and check that the trackball now works as 
intended. 
NOTE: Plastic hood is not 
supposed to be flush due 
to curvature on...

Page 60

 GE Logiq E9/Vivid E9 Training Manual 
© 2016 Conquest Imaging 53 
Module 6 General Safety Precautions 
This section is not intended to be an all inclusive safety procedure 
guide. It is only brief overview of best practices that applies to all 
health care facilities and types of medical equipment. You should be 
familiar with the policies and procedures of the facility where you 
work AND the safety precautions and procedures described in the 
manufacturer’s documentation for a particular OEM....
Start reading GE Vivid E9 User Manual

Related Manuals for GE Vivid E9 User Manual

All GE manuals