Page 451
OB Table Editor LOGIQ 5 Basic User Manual 9-85 Direction 2300002-100 Rev. 2 O B Ta b l e Te m p l a t e s Tool Type: • Distance: 2D Caliper • Circumference: 2D Ellipse, 2D Trace, 2D Caliper Te m p l a t e 1 Table 9-4: Template 1 (based on Hadlock) Template 1: SD Range Table Fetal Age Table Table Format MEAS MEAN SD Table Unit mm Week Week Table Range 1SD Graph Range 1SD Measurement Result Value [cm] GA [#w#d] Min [#w#d] Max [#w#d] Fetal Growth Table Table Format AGE MEAN SD Table Unit Week mm Week...
Page 452
OB/GYN 9-86 LOGIQ 5 Basic User Manual Direction 2300002-100 Rev. 2 Te m p l a t e 2 Te m p l a t e 3 Table 9-5: Template 2 (based on Tokyo) Template 2: SD Range Table Fetal Age Table Table Format MEAS MEAN SD Table Unit mm Day Day Table Range 1SD Graph Range 1SD Measurement Result Value [cm] GA [#w#d] SD: day(+/-) Fetal Growth Table Table Format AGE MEAN SD Table Unit Day mm Day Others are same as above Table 9-6: Template 3 (based on Osaka) Template 3: SD Table Fetal Age Table Table Format MEAS MEAN...
Page 453
OB Table Editor LOGIQ 5 Basic User Manual 9-87 Direction 2300002-100 Rev. 2 Te m p l a t e 4 Table 9-7: Template 4 (based on several European tables) Template 4: 5%-95% Table Fetal Age Table Table Format MEAS MEAN SD Table Unit mm WeekDay mm Table Range 5%:95% Graph Range 5%:95% Measurement Result Value [cm] GA [#w#d] GP [%] GP is calculated by Fetal Growth Table. If you did not edit Growth Table, GP is not calculated by the system, Fetal Growth Table Table Format AGE MEAN SD Table Unit WeekDay mm...
Page 454
OB/GYN 9-88 LOGIQ 5 Basic User Manual Direction 2300002-100 Rev. 2 Te m p l a t e 5 Table 9-8: Template 5 (based on several European tables) Template 5: 5% - 95% Table Fetal Age Table Table Format MEAS MEAN SD Table Unit mm WeekDay mm Table Range 1SD Graph Range 5%:95% Measurement Result Value [cm] GA [#w#d] GP [%] GP is calculated by Fetal Growth Table. If you did not edit Growth Table, GP is not calculated by the system, Fetal Growth Table Table Format AGE MEAN MAX Table Unit WeekDay mm mm Table...
Page 455
OB Table Editor LOGIQ 5 Basic User Manual 9-89 Direction 2300002-100 Rev. 2 Te m p l a t e 6 Table 9-9: Template 6 (based on several European tables) Template 6: 10% - 90% Table Fetal Age Table Table Format MEAS MIN MEAN SD Table Unit mm WeekDay WeekDay WeekDay Table Range 10%-90% Graph Range 10%-90% Measurement Result Value [cm] GA [#w#d] GP [%] GP is calculated by Fetal Growth Table. If you did not edit Growth Table, GP is not calculated by the system, Fetal Growth Table Table Format AGE MIN MEAN SD...
Page 456
OB/GYN 9-90 LOGIQ 5 Basic User Manual Direction 2300002-100 Rev. 2 Te m p l a t e 7 Table 9-10: Template 7 (Based on several european tables) Template 7: 10% - 90% Table Fetal Age Table Table Format MEAS MEAN SD Table Unit mm WeekDay mm Table Range 1SD Graph Range 10%:90% Measurement Result Value [cm] GA [#w#d] GP [%] GP is calculated by Fetal Growth Table. If you did not edit Growth Table, GP is not calculated by the system, Fetal Growth Table Table Format AGE MEAN MAX Table Unit WeekDay mm mm Table...
Page 457
OB Table Editor LOGIQ 5 Basic User Manual 9-91 Direction 2300002-100 Rev. 2 OB Table Edit Menu The data you enter in the OB Table Edit Menu depends on whether the table type is Fetal Age or Fetal Growth. Fetal Age Table If you are creating or editing a Fetal Age table, the OB Table Edit Menu is as follows: Figure 9-28. OB Table Edit Menu: Fetal Age Table
Page 458
OB/GYN 9-92 LOGIQ 5 Basic User Manual Direction 2300002-100 Rev. 2 Fetal Age Table (continued) Complete the field1. Input value to Min, Max and Interval of the Parameters field. The system automatically fills in the MEAS column. Input value to the columns of MEAN and SD. NOTE: To move between the fields in the table, use the up, down, left, and right arrow keys. NOTE: You must enter a minimum of two rows of data. Any lines with a blank cell are not saved. To save the Table Data, move the Trackball...
Page 459
OB Table Editor LOGIQ 5 Basic User Manual 9-93 Direction 2300002-100 Rev. 2 Fetal Growth Table If you are creating or editing a Fetal Growth table, the OB Table Edit Menu is as follows: Figure 9-29. OB Table Edit Menu: Fetal Growth Table Complete the field1. Input value to the required columns. NOTE: To move between the fields in the table, use the up, down, left, and right arrow keys. NOTE: You must enter a minimum of two rows of data. Any lines with a blank cell are not saved. 2. To save the...
Page 460
OB/GYN 9-94 LOGIQ 5 Basic User Manual Direction 2300002-100 Rev. 2 GYN Measurements Introduction The Gynecology exam category includes the following three studies: • Generic. This study is common to all exam categories. See ‘Generic Measurements’ for more information. • General Gynecology. This study includes uterine, ovarian, ovarian follicle, and endometrium measurements. • OB/GYN Vessel. This study includes the following vessels: uterine, ovarian, umbilical, middle cerebral artery, aorta,...