Page 151
Optimizing M-Mode LOGIQ 5 Basic User Manual 5-27 Direction 2300002-100 Rev. 2 M-Mode Display Figure 5-4. M-Mode Display M-Mode Display Description, Format, Values (For Future Vadliation) M-Mode Gain Depth Scale IndicatorDisplays Overall M-Mode Gain as ##dB. Image depth, in cm. Time Scale Eight speeds: 16, 12, 8, 6, 4, 3, 2, 1. Major marker = 1 second. M-Mode Cursor Displays where the M-Mode Cursor is positioned.
Page 152
Optimizing the Image 5-28 LOGIQ 5 Basic User Manual Direction 2300002-100 Rev. 2 M-Mode Touch Panel Figure 5-5. M-Mode Touch Panel Scanning Hints HINTSThese M-Mode controls produce the following results: Edge Enhance. Affects border sharpness. Sweep Speed. Controls speed of M-Mode update. Dynamic Range. Affects the amount of gray scale information displayed.
Page 153
Optimizing M-Mode LOGIQ 5 Basic User Manual 5-29 Direction 2300002-100 Rev. 2 M/D Cursor DescriptionDisplays the M-Mode cursor on the B-Mode image. AdjustingTo activate/deactivate the M-Mode cursor, press M/D Cursor. Trackball to position M-Mode cursor. Va l u e sOn/Off. BenefitsLets you position the cursor before you go into M-Mode so that you can make optimum use of the larger B-Mode image. B Pause DescriptionToggles between simultaneous and update presentation while viewing Spectral Doppler....
Page 154
Optimizing the Image 5-30 LOGIQ 5 Basic User Manual Direction 2300002-100 Rev. 2 Sweep Speed DescriptionChanges the speed at which the timeline is swept. Available in M-Mode, M Color Flow Mode, and Doppler Mode. AdjustingTo increase/decrease, select Sweep Speed. Va l u e sM-Mode: 16, 12, 8, 6, 4, 3, 2, and 1 second sweeps across the display. Doppler Mode: 12, 8, 6, 5, 4, 3, 2, and 1 second sweeps. Values vary by probe and application. Sweep Speed values are returned to the factory or user preset...
Page 155
Optimizing M-Mode LOGIQ 5 Basic User Manual 5-31 Direction 2300002-100 Rev. 2 Anatomical M-Mode DescriptionAnatomical M-Mode gives you the ability to manipulate the cursor at different angles and positions. The M-Mode display changes according to a motion of the M cursor. Figure 5-6. Anatomical M Mode ActivatingTo activate Anatomical M-Mode, press the Anatomical M Touch Panel control.
Page 156
Optimizing the Image 5-32 LOGIQ 5 Basic User Manual Direction 2300002-100 Rev. 2 Anatomical M-Mode (continued) AdjustingUse the Touch Panel control and Trackball to position the M cursor over the required area of the B-Mode image. • Turn the Touch Panel control left or right to move the M cursor to the desired area. • Move the Trackball left/right to move the cursor line left/right. • Move the Trackball up/down to move the M cursor up/down. Va l u e sOn/Off. BenefitsColor Flow Mode and Color...
Page 157
Optimizing M Color Flow LOGIQ 5 Basic User Manual 5-33 Direction 2300002-100 Rev. 2 Optimizing M Color Flow M Color Flow Mode DescriptionM Color Flow is used for fetal cardiac applications. Color Flow overlays color on the M-Mode image using velocity and variance color maps. The Color Flow wedge overlays the B-Mode image and M-Mode timeline. The Color Flow maps available in M-Mode are the same as in Color Flow Mode. The size and position of the Color Flow window in B-Mode determines the size and...
Page 158
Optimizing the Image 5-34 LOGIQ 5 Basic User Manual Direction 2300002-100 Rev. 2 M Color Flow Mode (continued) BioeffectsChanging the Sweep Speed, Packet Size, Frame Rate/ Resolution, Zoom, PRF, and ROI size may change the TI and/or MI. Observe the output display for possible effects. Figure 5-7. M Color Flow, Page 1 Figure 5-8. M Color Flow, Page 2
Page 159
Optimizing Color Flow LOGIQ 5 Basic User Manual 5-35 Direction 2300002-100 Rev. 2 Optimizing Color Flow Intended Use Color Flow Mode is a Doppler Mode intended to add color- coded qualitative information concerning the relative velocity and direction of fluid motion within the B-Mode image. Introduction A typical examination using Color Flow Mode, 1. Follow the same procedure as described under B-Mode to locate the anatomical area of interest. 2. After optimizing the B-Mode image, add Color Flow....
Page 160
Optimizing the Image 5-36 LOGIQ 5 Basic User Manual Direction 2300002-100 Rev. 2 Activating Color Flow To activate Color Flow Mode, 1. Press CF (Color Flow). The CF window appears over the B- Mode image. Move the Trackball to move the CF window. Figure 5-9. Color Flow Mode Display Uses Color Flow is useful to see flow in a broad area. Color Flow allows visualization of flow in the whole image, whereas Doppler Mode provides spectral information in a smaller area. Color Flow is also sometimes used as...