GE HEALTHCARE DIRECTION 2286865, REVISION 14LOGIQ™ 7 SERVICE MANUAL Section 1-2 - Important Conventions 1-19 1-3-11 How to remove the Ghost CD-ROM The Ghost CD-ROM (Base System Software Load Image CD-ROM) is mounted on the PC-BOX inside the scanner using velcro tapes. The upper side of the PC-BOX cover contains sharp edge causing a FE to have possibility of cutting his hand if he removes the CD-ROM with the PC-BOX cover closed. Figure 1-6 How to Remove Ghost CD-ROM Ghost CD-ROM Sharp Edge PC-BOX...
Page 42
GE HEALTHCARE DIRECTION 2286865, REVISION 14LOGIQ™ 7 SERVICE MANUAL 1-20Section 1-2 - Important Conventions 1-3-11 How to remove the Ghost CD-ROM (cont’d) The sharp edge of the PC Box Cover are chamfered before shipment. However, the Ghost CD-ROM must be removed with the PC-Box cover open according to the following steps. 1.) Disconnect the DVI-D connector, then remove the four mounting bolts (three hex bolts and one phillips screw). 2.) Open the PC box cover and remove the Ghost CD-ROM from the PC box....
Page 43
GE HEALTHCARE DIRECTION 2286865, REVISION 14LOGIQ™ 7 SERVICE MANUAL Section 1-2 - Important Conventions 1-21 Section 1-4 EMC, EMI, and ESD 1-4-1 Electromagnetic Compatibility Electro Magnetic Compatibility describes a level of performance of a device within its electromagnetic environment. This environment consists of the device itself and its surroundings including other equipment, power sources and persons with which the device must interface. Inadequate compatibility results when a susceptible...
Page 44
GE HEALTHCARE DIRECTION 2286865, REVISION 14LOGIQ™ 7 SERVICE MANUAL 1-22Section 1-5 - Customer Assistance Section 1-5 Customer Assistance This system is not repairable by the customer. If this equipment does not work as indicated in the Operator Manual, please contact your service support center. If the service engineer needs additional information to repair this equipment, please contact the following address (The necessary information will be provided to the Service Engineer as needed). 1-5-1 System...
Page 45
GE HEALTHCARE DIRECTION 2286865, REVISION 14LOGIQ™ 7 SERVICE MANUAL Section 1-5 - Customer Assistance 1-23 1-5-2 Contact Information (cont’d) NOTE: If this equipment does not work as indicated in the Operator Manual(s), contact your support center. Have the system ID number available when you call.
Page 46
GE HEALTHCARE DIRECTION 2286865, REVISION 14LOGIQ™ 7 SERVICE MANUAL 1-24Section 1-5 - Customer Assistance This page was intentionally left blank.
Page 47
GE HEALTHCARE DIRECTION 2286865, REVISION 14LOGIQ™ 7 SERVICE MANUAL Section 2-1 - Overview 2-1 Chapter 2 Pre Installation Section 2-1 Overview 2-1-1 Purpose of this chapter 2 This chapter provides the information required to plan and prepare for the installation of a LOGIQ™ 7. Included are descriptions of the facility and electrical needs to be met by the purchaser of the unit. A checklist is also provided at the end of this section to help determine whether the proper planning and preparation is...
Page 48
GE HEALTHCARE DIRECTION 2286865, REVISION 14LOGIQ™ 7 SERVICE MANUAL 2-2Section 2-2 - General Console Requirements Section 2-2 General Console Requirements 2-2-1 Console Environmental Requirements 2-2-1-1 Cooling The cooling requirement for the LOGIQ™ 7 is 3500 BTU/hr. This figure does not include cooling needed for lights, people, or other equipment in the room. Each person in the room places an additional 300 BTU/hr. demand on the cooling system. 2-2-1-2 Lighting Bright light is needed for system...
Page 49
GE HEALTHCARE DIRECTION 2286865, REVISION 14LOGIQ™ 7 SERVICE MANUAL Section 2-2 - General Console Requirements 2-3 2-2-2 Electrical Requirements 2-2-2-1 Electrical Requirements NOTE: GE Medical Systems requires a dedicated power and ground for the proper operation of its Ultrasound equipment. This dedicated power shall originate at the last distribution panel before the system. Sites with a mains power system with defined Neutral and Line: The dedicated line shall consist of one phase, a neutral (not...
Page 50
GE HEALTHCARE DIRECTION 2286865, REVISION 14LOGIQ™ 7 SERVICE MANUAL 2-4Section 2-2 - General Console Requirements 2-2-2-5 Site Power Outlets A desiccated AC power outlet must be within reach of the unit without extension cords. Other outlets adequate for the external peripherals, medical and test equipment needed to support this unit must also be present within 1 m (3.2 ft.) of the unit. Electrical installation must meet all current local, state, and national electrical codes. 2-2-2-6 Unit Power Plug...